Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

TENS device for cervical pain during teleworking controlled remotely by mobile application

International Journal of Reconfigurable and Embedded Systems (IJRES) · Vol. 14 No. 1 (2025) · hlm. 60–68

DOI
10.11591/ijres.v14.i1.pp60-68
ISSN
2722-2608, 2089-4864
Terbit
2025-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Monitoring cervical muscle pain during teleworking, exacerbated by the COVID-19 pandemic and increased remote work, highlights electrotherapy as a crucial physical therapy tool to mitigate muscle pain and promote tissue recovery, addressing ergonomic and occupational health problems that affect the well-being of remote workers. The research proposes to design a transcutaneous electrical nerve stimulation (TENS) device to monitor cervical muscle pain during teleworking, addressing the urgent need for technological solutions to mitigate this problem and improve the quality of life of teleworkers through data acquisition and processing, hardware development, implementation device monitoring, and evaluation software. For this, a TENS device was designed with a graphical interface to treat muscle pain in the neck of teachers who do remote work, dividing it into four stages: signal acquisition and generation, Bluetooth communication with an Android device, signal conditioning, and amplification and protection, following a development scheme that includes circuit design in Proteus and the creation of a mobile application in App Inventor. In conclusion, it was obtained that the power supplies have an average error of less than 1%, indicating good general performance and confirming the consistency and optimal performance of the proposed therapies.

Kata kunci

Jaringan kolaborasi para penulis

27 penulis · 52 tautan kepenulisan bersama · 21 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • National University of San Marcos
  • Universidad Tecnológica del Perú
  • Universidad Nacional Tecnológica de Lima Sur
  • Seoul National University of Science and Technology
  • Institut National des Sciences Appliquées de Rennes
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Rafael EspinoUniversidad Tecnológica del Perú2
Oscar LlerenaSeoul National University of Science and Technology2
Fernando AlvaradoUniversidad Tecnológica del Perú1
Bill LoayzaNational University of San Marcos1
Alvaro YauriNational University of San Marcos1
Anyela AquinoInstitut National des Sciences Appliquées de Rennes1
K. AlvarezNational University of San Marcos1
Junior CotaquispeNational University of San Marcos1
Jordy YnquillaNational University of San Marcos1
Patrick RamosNational University of San Marcos1
Jose EcheniqueNational University of San Marcos1
Max DelgadoNational University of San Marcos1
Enzo FloresNational University of San Marcos1
José MonterreyUniversidad Tecnológica del Perú1
Nora Bertha La Serna PalominoNational University of San Marcos1
Fernando CardozaNational University of San Marcos1
Cristy SamaméNational University of San Marcos1
Antero Castro NietoUniversidad Tecnológica del Perú1
Frank RojasUniversidad Nacional Tecnológica de Lima Sur1
Fabrizzio ContrerasUniversidad Nacional Tecnológica de Lima Sur1
Juan AlvarezUniversidad Nacional Tecnológica de Lima Sur1
José DávilaNational University of San Marcos1
Ana LucasNational University of San Marcos1
Said VaraNational University of San Marcos1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijres.iaescore.com/index.php/IJRES/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">TENS device for cervical pain during teleworking controlled remotely by mobile application</dc:title>
	<dc:creator>Yauri, Ricardo</dc:creator>
	<dc:creator>Balvin, Juan</dc:creator>
	<dc:creator>Lobo, Renzo</dc:creator>
	<dc:subject xml:lang="en-US">Cervical muscle pain; Monitoring; Nerve stimulation; Telecommuting; TENS</dc:subject>
	<dc:description xml:lang="en-US">Monitoring cervical muscle pain during teleworking, exacerbated by the COVID-19 pandemic and increased remote work, highlights electrotherapy as a crucial physical therapy tool to mitigate muscle pain and promote tissue recovery, addressing ergonomic and occupational health problems that affect the well-being of remote workers. The research proposes to design a transcutaneous electrical nerve stimulation (TENS) device to monitor cervical muscle pain during teleworking, addressing the urgent need for technological solutions to mitigate this problem and improve the quality of life of teleworkers through data acquisition and processing, hardware development, implementation device monitoring, and evaluation software. For this, a TENS device was designed with a graphical interface to treat muscle pain in the neck of teachers who do remote work, dividing it into four stages: signal acquisition and generation, Bluetooth communication with an Android device, signal conditioning, and amplification and protection, following a development scheme that includes circuit design in Proteus and the creation of a mobile application in App Inventor. In conclusion, it was obtained that the power supplies have an average error of less than 1%, indicating good general performance and confirming the consistency and optimal performance of the proposed therapies.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijres.iaescore.com/index.php/IJRES/article/view/21375</dc:identifier>
	<dc:identifier>10.11591/ijres.v14.i1.pp60-68</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Reconfigurable and Embedded Systems (IJRES); Vol 14, No 1: March 2025; 60-68</dc:source>
	<dc:source>2722-2608</dc:source>
	<dc:source>2089-4864</dc:source>
	<dc:source>10.11591/ijres.v14.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijres.iaescore.com/index.php/IJRES/article/view/21375/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Institute of Advanced Engineering and Science (IAES)</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>