Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

An edge AIoT system for non-invasive biological indicators estimation and continuous health monitoring using PPG and ECG signals

International Journal of Reconfigurable and Embedded Systems (IJRES) · Vol. 15 No. 1 (2026) · hlm. 97–108

DOI
10.11591/ijres.v15.i1.pp97-108
ISSN
2722-2608, 2089-4864
Terbit
2026-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper presents the design and implementation of an artificial intelligence of things (AIoT)-based system that integrates deep learning and edge computing for real-time non-invasive health monitoring, focusing on the estimation of mean arterial pressure (MAP) alongside vital parameters such as heart rate (HR), blood oxygen saturation (SpO₂), and body temperature. Photoplethysmography (PPG) and electrocardiography (ECG) signals are acquired using low-power MAX30102 and AD8232 sensors, preprocessed with lightweight digital filters, and processed through a 1D convolutional neural network (CNN) deployed on a SEEED Studio XIAO ESP32S3 microcontroller. The model trained using the cuff-less blood pressure estimation dataset, achieved a mean absolute error (MAE) of 2.51 mmHg on the embedded microcontroller and 2.93 mmHg when validated against a standard blood pressure monitor. Experimental results demonstrate high accuracy, achieving a MAE below 5 mmHg, thereby meeting the AAMI and British Hypertension Society (BHS) Grade A standards for blood pressure measurement. The system achieves real-time inference with an average latency of 16 ms and efficient memory utilization, ensuring suitability for wearable and embedded devices. Physiological data are transmitted via Wi-Fi to a Firebase cloud platform and visualized through a cross-platform mobile application. The proposed system demonstrates strong potential for remote healthcare applications, particularly in continuous monitoring and early health risk detection.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • VNU University of Engineering and Technology
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijres.iaescore.com/index.php/IJRES/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">An edge AIoT system for non-invasive biological indicators estimation and continuous health monitoring using PPG and ECG signals</dc:title>
	<dc:creator>K. Nguyen, Hung</dc:creator>
	<dc:creator>V. Pham, Manh</dc:creator>
	<dc:subject xml:lang="en-US">Artificial intelligence of things; Biological indicators; Deep learning; Edge computing; Health monitoring</dc:subject>
	<dc:description xml:lang="en-US">This paper presents the design and implementation of an artificial intelligence of things (AIoT)-based system that integrates deep learning and edge computing for real-time non-invasive health monitoring, focusing on the estimation of mean arterial pressure (MAP) alongside vital parameters such as heart rate (HR), blood oxygen saturation (SpO₂), and body temperature. Photoplethysmography (PPG) and electrocardiography (ECG) signals are acquired using low-power MAX30102 and AD8232 sensors, preprocessed with lightweight digital filters, and processed through a 1D convolutional neural network (CNN) deployed on a SEEED Studio XIAO ESP32S3 microcontroller. The model trained using the cuff-less blood pressure estimation dataset, achieved a mean absolute error (MAE) of 2.51 mmHg on the embedded microcontroller and 2.93 mmHg when validated against a standard blood pressure monitor. Experimental results demonstrate high accuracy, achieving a MAE below 5 mmHg, thereby meeting the AAMI and British Hypertension Society (BHS) Grade A standards for blood pressure measurement. The system achieves real-time inference with an average latency of 16 ms and efficient memory utilization, ensuring suitability for wearable and embedded devices. Physiological data are transmitted via Wi-Fi to a Firebase cloud platform and visualized through a cross-platform mobile application. The proposed system demonstrates strong potential for remote healthcare applications, particularly in continuous monitoring and early health risk detection.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2026-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijres.iaescore.com/index.php/IJRES/article/view/21668</dc:identifier>
	<dc:identifier>10.11591/ijres.v15.i1.pp97-108</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Reconfigurable and Embedded Systems (IJRES); Vol 15, No 1: March 2026; 97-108</dc:source>
	<dc:source>2722-2608</dc:source>
	<dc:source>2089-4864</dc:source>
	<dc:source>10.11591/ijres.v15.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijres.iaescore.com/index.php/IJRES/article/view/21668/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Hung K. Nguyen, Manh V. Pham</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>