Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Design and structural modelling of patient-specific 3D-printed knee femur and tibia implants

International Journal of Reconfigurable and Embedded Systems (IJRES) · Vol. 14 No. 2 (2025) · hlm. 575–586

DOI
10.11591/ijres.v14.i2.pp575-586
ISSN
2722-2608, 2089-4864
Terbit
2025-07-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Arthritis is a degenerative joint condition that progressively damages the knee, leading to pain, stiffness, and limited mobility. To alleviate these symptoms and restore joint functionality, total knee arthroplasty (TKA) is performed. This procedure becomes necessary due to either sudden trauma to the knee or gradual wear and tear of the meniscus and cartilage. TKA involves meticulous planning, precise bone cutting, and the placement of prosthetic components made from high-density polyethylene and metal alloys. However, traditional methods creating customized knee implants are expensive and time-intensive. This study explores the challenges in manufacturing personalized knee implants for TKA and evaluates the potential of three-dimensional (3D) printing technology in this process. Variations in knee joint anatomy across populations complicate surgery, as optimal outcomes rely on precise alignment and implant dimensions. A preoperative computed tomography (CT) scan identifies the region of interest (ROI), such as the knee joint. The scan data is then processed using computer-aided design (CAD) software to generate a printable file. The patient’s CT scan data is converted into a standard triangulation language (STL) file and CAD models of the knee joint. Errors such as overlapping triangles or open loops in the STL file are corrected, and unwanted geometries near the ROI are removed. Resection techniques are applied to create CAD models tailored to the patient’s bone morphology. Fused deposition modeling (FDM) is then used to produce prototypes of the knee joint and implants. Despite visible layer lines in the printed prototypes, challenges encountered during the process were effectively resolved.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 9 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Maulana Azad National Institute of Technology
  • PRIST University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
R. AnanthakrishnanMaulana Azad National Institute of Technology1
Abhishek GoyalMaulana Azad National Institute of Technology1
H.K. DarjiAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijres.iaescore.com/index.php/IJRES/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Design and structural modelling of patient-specific 3D-printed knee femur and tibia implants</dc:title>
	<dc:creator>Sandeep, Bolugoddu</dc:creator>
	<dc:creator>Dhanushkodi, Saravanan</dc:creator>
	<dc:creator>Kumarasamy, Sudhakar</dc:creator>
	<dc:subject xml:lang="en-US">Knee replacement; Minimum joint space width; Osteoarthritis; Parametric modeling; Three-dimensional model</dc:subject>
	<dc:description xml:lang="en-US">Arthritis is a degenerative joint condition that progressively damages the knee, leading to pain, stiffness, and limited mobility. To alleviate these symptoms and restore joint functionality, total knee arthroplasty (TKA) is performed. This procedure becomes necessary due to either sudden trauma to the knee or gradual wear and tear of the meniscus and cartilage. TKA involves meticulous planning, precise bone cutting, and the placement of prosthetic components made from high-density polyethylene and metal alloys. However, traditional methods creating customized knee implants are expensive and time-intensive. This study explores the challenges in manufacturing personalized knee implants for TKA and evaluates the potential of three-dimensional (3D) printing technology in this process. Variations in knee joint anatomy across populations complicate surgery, as optimal outcomes rely on precise alignment and implant dimensions. A preoperative computed tomography (CT) scan identifies the region of interest (ROI), such as the knee joint. The scan data is then processed using computer-aided design (CAD) software to generate a printable file. The patient’s CT scan data is converted into a standard triangulation language (STL) file and CAD models of the knee joint. Errors such as overlapping triangles or open loops in the STL file are corrected, and unwanted geometries near the ROI are removed. Resection techniques are applied to create CAD models tailored to the patient’s bone morphology. Fused deposition modeling (FDM) is then used to produce prototypes of the knee joint and implants. Despite visible layer lines in the printed prototypes, challenges encountered during the process were effectively resolved.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-07-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijres.iaescore.com/index.php/IJRES/article/view/21546</dc:identifier>
	<dc:identifier>10.11591/ijres.v14.i2.pp575-586</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Reconfigurable and Embedded Systems (IJRES); Vol 14, No 2: July 2025; 575-586</dc:source>
	<dc:source>2722-2608</dc:source>
	<dc:source>2089-4864</dc:source>
	<dc:source>10.11591/ijres.v14.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijres.iaescore.com/index.php/IJRES/article/view/21546/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Institute of Advanced Engineering and Science (IAES)</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>