Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

HOMER optimization of standalone PV/Wind/Battery powered hydrogen refueling stations located at twenty selected French cities

International Journal of Renewable Energy Development : JRED · Vol. 12 No. 6 (2023) · hlm. 1070–1090

DOI
10.14710/ijred.2023.58218
ISSN
2252-4940
Terbit
2023-11-01
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The current study proposes a model of autonomous Hydrogen Refuelling Stations (HRFS) installed on different sites in twenty French cities powered by renewable clean energy sources. The station is fully powered by photovoltaic (PV) panels, wind turbines with battery storage and involving an electrolyzer and hydrogen tank for producing and storing hydrogen. Using Homer simulation, three scenarios are investigated to propose an optimized model, namely Scenario 1 containing (PV-Wind-Battery) system, Scenario 2 with (Wind-Battery) technologies and Scenario 3 with (PV-Battery) components. The otimization process executed demonstrates very competitive levelized cost of energy (LCOE) and levelized cost of hydrogen (LCOH) especially for the third scenario solely based on PV power with LCOE in range $0.354-0.435/kWh and a LCOH varying within $13.5-16.5/kg, for all 20 cities. An average net present cost (NPC) value of $ 1,561,429 and $ 2,522,727 are predicted for the first and second architectures while least net present cost of $1,038,117 is estimated for the third combination solely based on solar power according to all sites considered. For instance, minimum values are obtained for Marseille city with LCOE=$ 0.354/kWh and a LCOH=$ 13.5 /kg in conformity with the minimum obtained value of NPC value of $886,464 with respect to the winner third scenario. In addition, more costly hydrogen production is expected for Grenoble city especially for scenario 1 and 2 where wind turbine technology is introduced. On another hand, thorough analysis of PV/wind hydrogen techno-economic operation is provided including improvements recommendations, scenarios comparison and environmental impact discussion.

Kata kunci

Jaringan kolaborasi para penulis

Belum ada rekan penulis di Melola.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">HOMER optimization of standalone PV/Wind/Battery powered hydrogen refueling stations located at twenty selected French cities</dc:title>
	<dc:creator>Oueslati, Fakher</dc:creator>
	<dc:subject xml:lang="en-US">Hydrogen refuelling station, Renewable resources, techno-economic analysis, HOMER software, Levelized cost of hydrogen</dc:subject>
	<dc:description xml:lang="en-US">The current study proposes a model of autonomous Hydrogen Refuelling Stations (HRFS) installed on different sites in twenty French cities powered by renewable clean energy sources. The station is fully powered by photovoltaic (PV) panels, wind turbines with battery storage and involving an electrolyzer and hydrogen tank for producing and storing hydrogen. Using Homer simulation, three scenarios are investigated to propose an optimized model, namely Scenario 1 containing (PV-Wind-Battery) system, Scenario 2 with (Wind-Battery) technologies and Scenario 3 with (PV-Battery) components. The otimization process executed demonstrates very competitive levelized cost of energy (LCOE) and levelized cost of hydrogen (LCOH) especially for the third scenario solely based on PV power with LCOE in range $0.354-0.435/kWh and a LCOH varying within $13.5-16.5/kg, for all 20 cities. An average net present cost (NPC) value of $ 1,561,429 and $ 2,522,727 are predicted for the first and second architectures while least net present cost of $1,038,117 is estimated for the third combination solely based on solar power according to all sites considered. For instance, minimum values are obtained for Marseille city with LCOE=$ 0.354/kWh and a LCOH=$ 13.5 /kg in conformity with the minimum obtained value of NPC value of $886,464 with respect to the winner third scenario. In addition, more costly hydrogen production is expected for Grenoble city especially for scenario 1 and 2 where wind turbine technology is introduced. On another hand, thorough analysis of PV/wind hydrogen techno-economic operation is provided including improvements recommendations, scenarios comparison and environmental impact discussion.</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2023-11-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/58218</dc:identifier>
	<dc:identifier>10.14710/ijred.2023.58218</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 12, No 6 (2023): November 2023; 1070-1090</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/58218/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 The Author(s). Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>