This document presents a research article on the control of fluid flow around three heated square cylinders placed side by side in a 2D horizontal channel using a flat plate. The objective of this research is to examine the effect of the position, length and height of a flat plate on fluid flow and heat transfer. For this purpose, numerical simulations are performed by using the Boltzmann double relaxation time multiple network method (DMRT-LBM). The MRT-D2Q9 and MRT-D2Q5 models are used to treat the flow and temperature fields respectively. In contrast to several existing investigations in the literature in this domain which study the passive control of the flow using a horizontal or vertical plate around a single cylinder, this work presents a numerical study on the effect of the position, length and height of a flat plate (horizontal and vertical) on three heated square cylinders on the flow and temperature fields. First, the effect of the position and length of the horizontal flat plate is examined. This study shows that the implementation of a flat plate of length Lp = 4D at a position g=3 behind the central cylinder reduces the amplitude of the Von Karman Street and allows large and regular heat exchange. Thus, in the second part, the effect of the position and height of the vertical flat plate is studied. The results obtained show that the implementation of a flat plate of height h=2D at a position g=3 behind the central cylinder improves the thermal exchange between the incoming fluid and the heated cylinders. This numerical work could lead to the prediction of the cooling of the electronic components: The cooling of the obstacles is all the better when the control plate is arranged at g = 3 and its height h = 2D in the case of the vertical plate or its length Lp equal to 4D in the case where the plate is implemented horizontally

Kata kunci

Jaringan kolaborasi para penulis

9 penulis · 24 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mohamed I University
  • Laboratoire de Génie Civil et Géo-Environnement
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mohammed JamiMohamed I University7
El Bachir LahmerMohamed I University5
Salaheddine ChannoufMohamed I University5
Jaouad BenhamouMohamed I University2
Hanane Ait Lahoussine OualiMohamed I University2
Hassane NajiLaboratoire de Génie Civil et Géo-Environnement2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Numerical Investigation of Convective Heat Transfer and Fluid Flow Past a Three Square Cylinders Controlled by a Partition in Channel</dc:title>
	<dc:creator>Admi, Youssef</dc:creator>
	<dc:creator>Moussaoui, Mohammed Amine</dc:creator>
	<dc:creator>Mezrhab, Ahmed</dc:creator>
	<dc:subject xml:lang="en-US">Partition control; Square cylinders; Heat transfer; Flow field; Multiple Relaxation Time Lattice Boltzmann method</dc:subject>
	<dc:description xml:lang="en-US">This document presents a research article on the control of fluid flow around three heated square cylinders placed side by side in a 2D horizontal channel using a flat plate. The objective of this research is to examine the effect of the position, length and height of a flat plate on fluid flow and heat transfer. For this purpose, numerical simulations are performed by using the Boltzmann double relaxation time multiple network method (DMRT-LBM). The MRT-D2Q9 and MRT-D2Q5 models are used to treat the flow and temperature fields respectively. In contrast to several existing investigations in the literature in this domain which study the passive control of the flow using a horizontal or vertical plate around a single cylinder, this work presents a numerical study on the effect of the position, length and height of a flat plate (horizontal and vertical) on three heated square cylinders on the flow and temperature fields. First, the effect of the position and length of the horizontal flat plate is examined. This study shows that the implementation of a flat plate of length Lp = 4D at a position g=3 behind the central cylinder reduces the amplitude of the Von Karman Street and allows large and regular heat exchange.  Thus, in the second part, the effect of the position and height of the vertical flat plate is studied. The results obtained show that the implementation of a flat plate of height h=2D at a position g=3 behind the central cylinder improves the thermal exchange between the incoming fluid and the heated cylinders. This numerical work could lead to the prediction of the cooling of the electronic components: The cooling of the obstacles is all the better when the control plate is arranged at g = 3 and its height h = 2D in the case of the vertical plate or its length Lp equal to 4D in the case where the plate is implemented horizontally</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2022-08-04</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/43790</dc:identifier>
	<dc:identifier>10.14710/ijred.2022.43790</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 11, No 3 (2022): August 2022; 766-781</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/43790/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 The Author(s). Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>