Abstrak

This paper has adopted the new bio-inspired Manta-Ray Foraging Optimization (MRFO) algorithm for optimal allocation of multiple Distributed Generation (DG) units attached to Radial Distribution Systems (RDSs) in order to reduce the total energy loss of the studied system. The DG units are optimized to work with a unity power factor (UPF) and optimal power factor (OPF) during a 24-h time-varying demand. The MRFO algorithm optimized single, two, and three DG units. The total energy loss and energy-saving during the time-varying demand are calculated and compared with the original case. The MRFO algorithm behavior is compared to the Particle Swarm Optimization (PSO) and Atom Search Optimization (ASO) algorithms regarding energy loss and energy-saving values. The standard 69-bus RDS is used as a test system. Considerable improvements in energy saving, loss reduction, and voltage profile are achieved after installing DG units, mainly when operating with optimal power factors. The MRFO algorithm achieves energy losses of 817.91, 751.08, and 730.25 kWh with 1, 2, and 3 DG units with UPF allocations, respectively. On the other hand, when the DG units are optimized to work with OPF, the MRFO achieves energy losses of 233.24, 142.08, and 106.79 kWh with the same number of DG units, respectively. Furthermore, the MRFO algorithm has efficient behavior compared with the PSO, ASO, and other algorithms for different operations and conditions.

Kata kunci

Jaringan kolaborasi para penulis

17 penulis · 31 tautan kepenulisan bersama · 9 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Ain Shams University
  • Aswan University
  • The Future University
  • Kafrelsheikh University
  • Menoufia University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mahmoud A. SolimanAin Shams University2
Mahmoud A. AttiaAin Shams University2
Said Fouad MekhamerThe Future University1
R. H. ShehataAin Shams University1
Mostafa A. Al-GabalawyThe Future University1
Rabab M. I. El-HassaniAin Shams University1
Mahmoud M. El-SharkawyAin Shams University1
Niveen M. BadraAin Shams University1
Mohamed S. GhayadAin Shams University1
Mina N. AminAin Shams University1
Hany Mohamed HasanienAin Shams University1
Ragab Abdelaziz El-SehiemyKafrelsheikh University1
Ahmed R. AdlyAfiliasi tidak diketahui1
Mahmoud A. ElsaddMenoufia University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Energy Loss Reduction of Distribution Systems Equipped with Multiple Distributed Generations Considering Uncertainty using Manta-Ray Foraging Optimization</dc:title>
	<dc:creator>Eid, Ahmad</dc:creator>
	<dc:creator>Abdelaziz, Almoataz Y.</dc:creator>
	<dc:creator>Dardeer, Mostafa</dc:creator>
	<dc:subject xml:lang="en-US">MRFO; DG optimal allocations; Time-varying demand; Energy loss; Distribution systems</dc:subject>
	<dc:description xml:lang="en-US">This paper has adopted the new bio-inspired Manta-Ray Foraging Optimization (MRFO) algorithm for optimal allocation of multiple Distributed Generation (DG) units attached to Radial Distribution Systems (RDSs) in order to reduce the total energy loss of the studied system. The DG units are optimized to work with a unity power factor (UPF) and optimal power factor (OPF) during a 24-h time-varying demand. The MRFO algorithm optimized single, two, and three DG units. The total energy loss and energy-saving during the time-varying demand are calculated and compared with the original case. The MRFO algorithm behavior is compared to the Particle Swarm Optimization (PSO) and Atom Search Optimization (ASO) algorithms regarding energy loss and energy-saving values. The standard 69-bus RDS is used as a test system. Considerable improvements in energy saving, loss reduction, and voltage profile are achieved after installing DG units, mainly when operating with optimal power factors. The MRFO algorithm achieves energy losses of 817.91, 751.08, and 730.25 kWh with 1, 2, and 3 DG units with UPF allocations, respectively. On the other hand, when the DG units are optimized to work with OPF, the MRFO achieves energy losses of 233.24, 142.08, and 106.79 kWh with the same number of DG units, respectively. Furthermore, the MRFO algorithm has efficient behavior compared with the PSO, ASO, and other algorithms for different operations and conditions.</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2021-11-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/37482</dc:identifier>
	<dc:identifier>10.14710/ijred.2021.37482</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 10, No 4 (2021): November 2021; 779-787</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/37482/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 The Authors. Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>