A techno-economic and environmental analysis of co-firing implementation using coal and wood bark blend at circulating fluidized bed boiler

International Journal of Renewable Energy Development : JRED · Vol. 13 No. 4 (2024) · hlm. 726–735

DOI
10.61435/ijred.2024.60234
ISSN
2252-4940
Terbit
2024-07-01
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The study aimed to explore the effects of biomass co-firing of coal using acacia wood bark at circulating fluidized bed (CFB) boiler coal-fired power plant with 110 MWe capacity. The analysis focused on main equipment parameters, including the potential for slagging, fouling, corrosion, agglomeration, fuel cost, and specific environmental factors. Initially, coal and acacia wood bark fuel were blended at a 3% mass ratio, with calorific values of 8.59 MJ/kg and 16.59 MJ/kg, respectively. The corrosion due to chlorine and slagging potential when using wood bark was grouped into the minor and medium categories. The results showed that co-firing at approximately 3% mass ratio contributed to changes in the upper furnace temperature due to the variation in heating value, high total humidity, and a less homogeneous particle size distribution. Significant differences were also observed in the temperature of the lower furnace area, showing the presence of a foreign object covering the nozzle, which disturbed the ignition process. A comparison of the seal pot temperature showed imbalances as observed from the temperature indicators installed on both sides of boiler, with specific fuel consumption (SFC) increasing by approximately 0.17%. During the performance test, the price of acacia wood bark was 0.034 USD/kg, resulting in fuel cost of 0.023355 USD/kWh, adding 0.061 cent/kWh to coal firing cost. Despite co-firing, the byproducts of the combustion process, such as SO2 and NOx, still met environmental quality standards in accordance with government regulations. However, a comprehensive medium- and long-term impact evaluation study should be carried out to implement co-firing operations using acacia wood bark at coal-fired power plant. Based on the characteristics, such as low calorific value, with high ash, total moisture, and alkali, acacia wood bark showed an increased potential to cause slagging and fouling.

Kata kunci

Jaringan kolaborasi para penulis

25 penulis · 80 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas PGRI Wiranegara
  • Lambung Mangkurat University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Handrea Bernando TambunanAfiliasi tidak diketahui1
Ruly Bayu SitanggangAfiliasi tidak diketahui1
Muhammad Muslih MafruddinAfiliasi tidak diketahui1
Oksa PrasetyawanAfiliasi tidak diketahui1
Kensianesi KensianesiAfiliasi tidak diketahui1
Istiqomah IstiqomahAfiliasi tidak diketahui1
Fefria TanbarAfiliasi tidak diketahui1
Supriyo SupriyoUniversitas PGRI Wiranegara1
Heru MugiarsoAfiliasi tidak diketahui1
Ari PermanaAfiliasi tidak diketahui1
Wilson SusantoAfiliasi tidak diketahui1
Endiarjati Dewandaru SadonoAfiliasi tidak diketahui1
Irine Handika IkasariAfiliasi tidak diketahui1
Muhammad Akhsin MuflikhunAfiliasi tidak diketahui1
Faisal FaisalLambung Mangkurat University1
Hasnan BachtiarAfiliasi tidak diketahui1
Christine B TenorioAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">A techno-economic and environmental analysis of co-firing implementation using coal and wood bark blend at circulating fluidized bed boiler</dc:title>
	<dc:creator>Cahyo, Nur</dc:creator>
	<dc:creator>Sulistyowati, Desy</dc:creator>
	<dc:creator>Rahmanta, Mujammil Asdhiyoga</dc:creator>
	<dc:creator>Felani, Muhamad Iqbal</dc:creator>
	<dc:creator>Soleh, Mochamad</dc:creator>
	<dc:creator>Paryanto, Paryanto</dc:creator>
	<dc:creator>Prismantoko, Adi</dc:creator>
	<dc:creator>Hariana, Hariana</dc:creator>
	<dc:subject xml:lang="en-US">co-firing; biomass; wood bark; CFB boiler; corrosion; slagging; fouling; emission; fuel cost</dc:subject>
	<dc:description xml:lang="en-US">The study aimed to explore the effects of biomass co-firing of coal using acacia wood bark at circulating fluidized bed (CFB) boiler coal-fired power plant with 110 MWe capacity. The analysis focused on main equipment parameters, including the potential for slagging, fouling, corrosion, agglomeration, fuel cost, and specific environmental factors. Initially, coal and acacia wood bark fuel were blended at a 3% mass ratio, with calorific values of 8.59 MJ/kg and 16.59 MJ/kg, respectively. The corrosion due to chlorine and slagging potential when using wood bark was grouped into the minor and medium categories. The results showed that co-firing at approximately 3% mass ratio contributed to changes in the upper furnace temperature due to the variation in heating value, high total humidity, and a less homogeneous particle size distribution. Significant differences were also observed in the temperature of the lower furnace area, showing the presence of a foreign object covering the nozzle, which disturbed the ignition process. A comparison of the seal pot temperature showed imbalances as observed from the temperature indicators installed on both sides of boiler, with specific fuel consumption (SFC) increasing by approximately 0.17%. During the performance test, the price of acacia wood bark was 0.034 USD/kg, resulting in fuel cost of 0.023355 USD/kWh, adding 0.061 cent/kWh to coal firing cost. Despite co-firing, the byproducts of the combustion process, such as SO2 and NOx, still met environmental quality standards in accordance with government regulations. However, a comprehensive medium- and long-term impact evaluation study should be carried out to implement co-firing operations using acacia wood bark at coal-fired power plant. Based on the characteristics, such as low calorific value, with high ash, total moisture, and alkali, acacia wood bark showed an increased potential to cause slagging and fouling.</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2024-07-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/60234</dc:identifier>
	<dc:identifier>10.61435/ijred.2024.60234</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 13, No 4 (2024): July 2024; 726-735</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/60234/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 The Author(s). Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>