Abstrak

A prior study on the performance of high-efficient models for a heliostat field and solar receiver at various candidate locations (e.g., certain regions in the south of Turkey) helped determine suitable locations for installing solar tower power plant units. This study considered the fact that solar tower power plants are affected by the working conditions of a particular site, which helps realize the highest performance of the solar power tower plant. An optimized heliostat field consisting of 2650 SENER heliostats and a model of a solar receiver based on the data obtained using Gemasolar in Seville, Spain, was used as a reference in this work. Each heliostat position is specified using an optimization algorithm that refines previously proposed models, and two parameters are added to this model to further optimize the heliostat layout. Then, a sample analytical thermal model is used for predicting the radiative and convective heat losses from the receiver system. Article History: Received March 13rd 2016; Received in revised form Jun 22nd 2016; Accepted July 3rd 2016; Available onlineHow to Cite This Article: Ra'ad, K, M, A. and Mehmet, S, S. (2016), Evaluating the potential energy of a heliostat field and solar receiver of solar tower power plants in the southern region of Turkey. Int. Journal of Renewable Energy Development, 5(2), 151-161,http://dx.doi.org/10.14710/ijred.5.2.151-161

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 2 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Gaziantep University
  • University of Baghdad
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Hisham Al-SaddyUniversity of Baghdad1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Evaluating the potential energy of a heliostat field and solar receiver of solar tower power plants in the southern region of Turkey</dc:title>
	<dc:creator>Al-Dualimi, Raad Kadhim</dc:creator>
	<dc:creator>Söylemez, Mehmet Sait</dc:creator>
	<dc:subject xml:lang="en-US">heliostat field, simulation, solar power tower plant, solar receiver, Turkey</dc:subject>
	<dc:description xml:lang="en-US">A prior study on the performance of high-efficient models for a heliostat field and solar receiver at various candidate locations (e.g., certain regions in the south of Turkey) helped determine suitable locations for installing solar tower power plant units. This study considered the fact that solar tower power plants are affected by the working conditions of a particular site, which helps realize the highest performance of the solar power tower plant. An optimized heliostat field consisting of 2650 SENER heliostats and a model of a solar receiver based on the data obtained using Gemasolar in Seville, Spain, was used as a reference in this work. Each heliostat position is specified using an optimization algorithm that refines previously proposed models, and two parameters are added to this model to further optimize the heliostat layout. Then, a sample analytical thermal model is used for predicting the radiative and convective heat losses from the receiver system. Article History: Received March 13rd 2016; Received in revised form Jun 22nd 2016; Accepted July 3rd 2016; Available onlineHow to Cite This Article: Ra'ad, K, M, A. and Mehmet, S, S. (2016), Evaluating the potential energy of a heliostat field and solar receiver of solar tower power plants in the southern region of Turkey. Int. Journal of Renewable Energy Development, 5(2), 151-161,http://dx.doi.org/10.14710/ijred.5.2.151-161 </dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2016-07-15</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/10593</dc:identifier>
	<dc:identifier>10.14710/ijred.5.2.151-161</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 5, No 2 (2016): July 2016; 151-161</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/10593/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2016 International Journal of Renewable Energy Development</dc:rights>
</oai_dc:dc>