Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Modeling and Experimental Validation of a Transient Direct Expansion Heat Pump

International Journal of Renewable Energy Development : JRED · Vol. 6 No. 2 (2017) · hlm. 145–155

DOI
10.14710/ijred.6.2.145-155
ISSN
2252-4940
Terbit
2017-06-25
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Geothermal heat pump technology is currently one of the most interesting technologies used to heat buildings. There are two designs used in the industry: geothermal heat pump using a secondary ground loop and Direct Expansion (DX) ground source heat pump. The latter is less used, possibly because less research has been carried out for the design of this kind of heat pump. In this paper, a transient model using the Comsol Multiphysic of a DX ground heat pump is presented in heating mode with R22, and a comparison with experimental results is presented with a 24-hour test. It is shown that the model was adequately validated by our experiment with only a maximum difference of 15%. Following this validation, a parametric analysis was realised on the geometry of the borehole. This study concluded that to have the best heat extraction of the ground, the pipes shank spacing need to be important without increasing the borehole diameter.Article History: Received January 16th 2017; Received in revised form May 28th 2017; Accepted June 6th 2017; Available onlineHow to Cite This Article: Rousseau, C., Fannou, J.L.C., Lamarche, L. and Kajl, S. (2017) Modeling and Experimental Validation of a Transient Direct Expansion Heat Pump. International Journal of Renewable Energy Development, 6(2), 145-155.https://doi.org/10.14710/ijred.6.2.145-155

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 6 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • École de Technologie Supérieure
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Modeling and Experimental Validation of a Transient Direct Expansion Heat Pump</dc:title>
	<dc:creator>Rousseau, Clément</dc:creator>
	<dc:creator>Fannou, Jean-Louis Comlan</dc:creator>
	<dc:creator>Lamarche, Louis</dc:creator>
	<dc:creator>Kajl, Stanislaw</dc:creator>
	<dc:subject xml:lang="en-US">Direct Expansion geothermal heat pump, Modeling, R22</dc:subject>
	<dc:description xml:lang="en-US">Geothermal heat pump technology is currently one of the most interesting technologies used to heat buildings. There are two designs used in the industry: geothermal heat pump using a secondary ground loop and Direct Expansion (DX) ground source heat pump. The latter is less used, possibly because less research has been carried out for the design of this kind of heat pump. In this paper, a transient model using the Comsol Multiphysic of a DX ground heat pump is presented in heating mode with R22, and a comparison with experimental results is presented with a 24-hour test. It is shown that the model was adequately validated by our experiment with only a maximum difference of 15%. Following this validation, a parametric analysis was realised on the geometry of the borehole. This study concluded that to have the best heat extraction of the ground, the pipes shank spacing need to be important without increasing the borehole diameter.Article History: Received January 16th 2017; Received in revised form May 28th 2017; Accepted June 6th 2017; Available onlineHow to Cite This Article: Rousseau, C., Fannou, J.L.C., Lamarche, L. and Kajl, S. (2017) Modeling and Experimental Validation of a Transient Direct Expansion Heat Pump. International Journal of Renewable Energy Development, 6(2), 145-155.https://doi.org/10.14710/ijred.6.2.145-155</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2017-06-25</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/14728</dc:identifier>
	<dc:identifier>10.14710/ijred.6.2.145-155</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 6, No 2 (2017): July 2017; 145-155</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/14728/pdf</dc:relation>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>