Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Multi-criteria optimal sizing and analysis of PV/wind/fuel cell/battery/diesel generator for rural electrification: A case study in Chad

International Journal of Renewable Energy Development : JRED · Vol. 13 No. 3 (2024) · hlm. 491–507

DOI
10.61435/ijred.2024.60169
ISSN
2252-4940
Terbit
2024-05-01
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Access to sustainable, clean, affordable, and reliable electricity is crucial for social and economic development, yet Sub-Saharan Africa (SSA) struggles significantly in this context. In CHAD, only 11.3% of the population is able to access electricity, making it one of the least electrified countries in SSA with the lowest clean energy access. In rural areas, electricity access falls to just 1.3%. This research applies and executes a Multi-Objective Particle Swarm Optimization (MOPSO) algorithm using MATLAB R2023b to assess the techno-economic, environmental, and social impacts of a hybrid system based on optimal PV/Wind/Battery/Fuel Cell (FC)/Diesel generator (DG) sizing for rural electrification in CHAD. The proposed system's self-sufficiency index (SSSI) and the Annualized System Cost (ASC) were chosen as objective functions to guarantee the economic feasibility of the system, higher self-sufficiency, and lower dependence on external energy sources (DG). The simulation results show that the optimal size of the proposed system supplies the load demand by 100% of the renewable energy sources (RES) fraction, and the optimal capacities of the main components to supply the load demand are: Solar Power (493 KW), Wind Turbine (166 KW), Battery Energy Charge/Discharge (229180 kWh /221300 kWh), Hydrogen tank storage energy (83 874 kWh), Electrolyzer size (202 KW), Fuel cell size (144 KW). The evelized cost of electricity (LCOE) of 0.2982 $/kWh, which is 51.12% lower than the national unit production costs of electricity in rural areas of CHAD (0.61 $/kWh). This LCOE is also the lowest compared to previous works done using HOMER Pro for the country of CHAD. The results also give a levelized cost of hydrogen (LCOH) of 3.8563 US $/kg, lower than for all studies found in the literature for the country of Chad. The proposed system's yearly avoided greenhouse gas (GHG) emission is 374 640 kg. The proposed system will create five (5) new jobs (JCO) and improve the Human Development Index (HDI) of the study area by 17.66% (the obtained HDI is 0.4683, and the CHAD HDI is 0.398) with an SSSI of 51.14%. This study provides a better practical energy design tool in decision-making for designers, companies, investors, policymakers, and the Chadian government when implementing this type of system in particular rural locations.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 6 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Nairobi
  • Korea Institute of Energy Research
  • University of Eldoret
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Multi-criteria optimal sizing and analysis of PV/wind/fuel cell/battery/diesel generator for rural electrification: A case study in Chad</dc:title>
	<dc:creator>Abdoulaye, Mahamat Adoum</dc:creator>
	<dc:creator>Waita, Sebastian</dc:creator>
	<dc:creator>Wekesa, Cyrus Wabuge</dc:creator>
	<dc:creator>Mwabora, Julius Mwakondo</dc:creator>
	<dc:subject xml:lang="en-US">Avoided greenhouse gas (GHG); social assessment; Hybrid energy system; Optimal sizing; rural electrification; Particle Swarm Optimization algorithm; zero-carbon electricity.</dc:subject>
	<dc:description xml:lang="en-US">Access to sustainable, clean, affordable, and reliable electricity is crucial for social and economic development, yet Sub-Saharan Africa (SSA) struggles significantly in this context. In CHAD, only 11.3% of the population is able to access electricity, making it one of the least electrified countries in SSA with the lowest clean energy access. In rural areas, electricity access falls to just 1.3%. This research applies and executes a Multi-Objective Particle Swarm Optimization (MOPSO) algorithm using MATLAB R2023b to assess the techno-economic, environmental, and social impacts of a hybrid system based on optimal PV/Wind/Battery/Fuel Cell (FC)/Diesel generator (DG) sizing for rural electrification in CHAD. The proposed system's self-sufficiency index (SSSI) and the Annualized System Cost (ASC) were chosen as objective functions to guarantee the economic feasibility of the system, higher self-sufficiency, and lower dependence on external energy sources (DG). The simulation results show that the optimal size of the proposed system supplies the load demand by 100% of the renewable energy sources (RES)  fraction, and the optimal capacities of the main components to supply the load demand are: Solar Power (493 KW), Wind Turbine (166 KW), Battery Energy Charge/Discharge (229180 kWh /221300 kWh), Hydrogen tank storage energy (83 874 kWh), Electrolyzer size (202 KW), Fuel cell size (144 KW). The evelized cost of electricity (LCOE) of 0.2982 $/kWh, which is 51.12% lower than the national unit production costs of electricity in rural areas of CHAD (0.61 $/kWh). This LCOE is also the lowest compared to previous works done using HOMER Pro for the country of CHAD. The results also give a levelized cost of hydrogen (LCOH) of 3.8563 US $/kg, lower than for all studies found in the literature for the country of Chad. The proposed system's yearly avoided greenhouse gas (GHG) emission is 374 640 kg. The proposed system will create five (5) new jobs (JCO) and improve the Human Development Index (HDI) of the study area by 17.66% (the obtained HDI is 0.4683, and the CHAD HDI is 0.398) with an SSSI of 51.14%. This study provides a better practical energy design tool in decision-making for designers, companies, investors, policymakers, and the Chadian government when implementing this type of system in particular rural locations.</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2024-05-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/60169</dc:identifier>
	<dc:identifier>10.61435/ijred.2024.60169</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 13, No 3 (2024): May 2024; 491-507</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/60169/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 The Author(s). Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>