Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Comparative thermo-economic and advanced exergy performance assessment of wind energy for distributed generation in four sites in Nigeria

International Journal of Renewable Energy Development : JRED · Vol. 9 No. 3 (2020) · hlm. 339–351

DOI
10.14710/ijred.9.3.339-351
ISSN
2252-4940
Terbit
2020-10-15
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Electricity access and reliability in Nigeria is poor due to obsolete power distribution infrastructure. This could be improved by deploying wind energy resources. The present research assessed the thermo-economic, advanced and extended exergy analysis of deploying wind turbine for distributed generation in four Nigerian locations. The air temperature and wind speed of the sites was used together with Weibull statistical parameters to mathematically model the thermodynamic performance of selected wind turbine for the sites. The results show that the energy and standard exergy efficiency of the sites ranges from 0.16 – 0.44, 0.05 – 0.37, 0.23 –0.39, 0.26 – 0.37 and 0.12 –0.33, 0.04 – 0.25, 0.17 – 0.28, 0.18 – 0.28 respectively for Enugu, Kaduna, Katsina and Jos. The exergy efficiency based on the extended exergy analysis (EEA) approach was found to be much lower than the standard exergy efficiency for all the sites. Based on EEA, Enugu, Kaduna, Katsina and Jos has exergy efficiency of 1.05, 0.73, 2.52 and 3.22 % respectively. Economic performance results showed that Jos is the best site with least monthly average COE value of 0.15 $/kWh which compares closely with global average COE value of 0.14 $/kWh for households. Katsina and Enugu have a COE value of 0.19 and 0.84 $/kWh respectively while Kaduna is the worst in performance with highest COE value of 1.13 $/kWh.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 10 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Enugu State University of Science and Technology
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Egwuagu OnyekachiEnugu State University of Science and Technology1
Thomas Okechukwu OnahEnugu State University of Science and Technology1
Ugwu Kenneth ChikwadoEnugu State University of Science and Technology1
Eberechukwu Chukwunyelum DimEnugu State University of Science and Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Comparative thermo-economic and advanced exergy performance assessment of wind energy for distributed generation in four sites in Nigeria</dc:title>
	<dc:creator>Diyoke, Chidiebere</dc:creator>
	<dc:subject xml:lang="en-US">Wind turbine, Exergy analysis, Advanced exergy, Extended exergy, Cost of electricity</dc:subject>
	<dc:description xml:lang="en-US">Electricity access and reliability in Nigeria is poor due to obsolete power distribution infrastructure. This could be improved by deploying wind energy resources. The present research assessed the thermo-economic, advanced and extended exergy analysis of deploying wind turbine for distributed generation in four Nigerian locations. The air temperature and wind speed of the sites was used together with Weibull statistical parameters to mathematically model the thermodynamic performance of selected wind turbine for the sites. The results show that the energy and standard exergy efficiency of the sites ranges from 0.16 – 0.44, 0.05 – 0.37, 0.23 –0.39, 0.26 – 0.37 and 0.12 –0.33, 0.04 – 0.25, 0.17 – 0.28, 0.18 – 0.28 respectively for Enugu, Kaduna, Katsina and Jos. The exergy efficiency based on the extended exergy analysis (EEA) approach was found to be much lower than the standard exergy efficiency for all the sites. Based on EEA, Enugu, Kaduna, Katsina and Jos has exergy efficiency of 1.05, 0.73, 2.52 and 3.22 % respectively. Economic performance results showed that Jos is the best site with least monthly average COE value of 0.15 $/kWh which compares closely with global average COE value of 0.14 $/kWh for households. Katsina and Enugu have a COE value of 0.19 and 0.84 $/kWh respectively while Kaduna is the worst in performance with highest COE value of 1.13 $/kWh. </dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2020-10-15</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/29602</dc:identifier>
	<dc:identifier>10.14710/ijred.9.3.339-351</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 9, No 3 (2020): October 2020; 339-351</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/29602/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 The Authors. Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>