Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Performance Analysis of Flat-Plate and V-groove Solar Air Heater Through CFD Simulation

International Journal of Renewable Energy Development : JRED · Vol. 9 No. 3 (2020) · hlm. 369–381

DOI
10.14710/ijred.2020.30091
ISSN
2252-4940
Terbit
2020-10-15
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The simplicity of solar flat plate air collector and free availability of solar energy sources attract attention to the optimization of the collector. This study aims to assess the effect of double pass air flow on the performance of flat plate air collectors. The analysis of the performance characteristics of the indirect solar dryer was carried out by CFD simulation with three different smooth, rough and V-grooved surfaces, keeping the lower and lateral collector well insulated and the drying chamber acting as a vertical chimney. The average thermal efficiency of the V-grooved surface, smooth surface, and rough surface is 90%, 78%, and 62% respectively. The total area of the collector is 1.20 × 2.0 = 2.40 m2 with the dimension of drying cabinet width, depth, and height 1200 × 650 × 1000 mm respectively. The pressure drop observed at the entrance to the drying chamber is high in the case of a smooth surface, medium in a rough surface and low in a V-grooved plate which will allow sufficient gas pressure to pass through completely.The air mass flow rate is the most important and effective factor during drying. The humidity of the air, as well as air velocity, is also an important factor in improving the drying rate.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jimma University
  • Wolkite University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Performance Analysis of Flat-Plate and V-groove Solar Air Heater Through CFD Simulation</dc:title>
	<dc:creator>Desisa, Debela Geneti</dc:creator>
	<dc:creator>Shekata, Gadisa Desa</dc:creator>
	<dc:subject xml:lang="en-US">CFD simulation; v-grooved surface; smooth surface; rough surface; double pass</dc:subject>
	<dc:description xml:lang="en-US">The simplicity of solar flat plate air collector and free availability of solar energy sources attract attention to the optimization of the collector. This study aims to assess the effect of double pass air flow on the performance of flat plate air collectors. The analysis of the performance characteristics of the indirect solar dryer was carried out by CFD simulation with three different smooth, rough and V-grooved surfaces, keeping the lower and lateral collector well insulated and the drying chamber acting as a vertical chimney. The average thermal efficiency of the V-grooved surface, smooth surface, and rough surface is 90%, 78%, and 62% respectively. The total area of the collector is 1.20 × 2.0 = 2.40 m2 with the dimension of drying cabinet width, depth, and height 1200 × 650 × 1000 mm respectively. The pressure drop observed at the entrance to the drying chamber is high in the case of a smooth surface, medium in a rough surface and low in a V-grooved plate which will allow sufficient gas pressure to pass through completely.The air mass flow rate is the most important and effective factor during drying. The humidity of the air, as well as air velocity, is also an important factor in improving the drying rate. </dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2020-10-15</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/30091</dc:identifier>
	<dc:identifier>10.14710/ijred.2020.30091</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 9, No 3 (2020): October 2020; 369-381</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/30091/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 The Authors. Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>