Akses terbuka
Jurnal
SINTA 1
Adaptation of VSC-HVDC Connected DFIG Based Offshore Wind Farm to Grid Codes: A Comparative Analysis
International Journal of Renewable Energy Development : JRED · Vol. 8 No. 1 (2019) · hlm. 91–101
ISSN 2252-4940
Terbit 2019-02-02
Penerbit Center of Biomass & Renewable Energy (CBIORE)
Bahasa eng
Abstrak
Lack of synchronism between VSC-HVDC (Voltage Source Converter - High Voltage Direct Current) connected offshore wind farm and onshore grid leads to immunity of wind turbines to grid contingencies. Focusing on DFIG (Doubly Fed Induction Generator) based wind farms; this paper has presented a univalent control structure based on inertial and primary frequency response in which DC link voltage is utilized as synchronization interface. Based on the presented structure, four approaches based on the communication system, frequency, voltage and combined frequency and voltage modulation are utilized and compared to inform the onshore grid status to individual wind turbines. Considering Kondurs two area power system, results have revealed that all four approaches have similar ability (with negligible error) in offering inertial and primary frequency response to improve slow network oscillations. On the other hand, voltage and combined frequency and voltage modulation approaches have the ability to satisfy Fault Ride Through (FRT) requirements thanks to superior dynamics. However, communication and frequency modulation approaches lose that ability as communication and frequency measurement delays increase respectively. It has been concluded that combined frequency and voltage modulation, as the superior approach, has advantages like minimum FRT DC voltage profile increase and deviation from operating point after the fault, the minimum imposition of electrical and mechanical stress on DFIG and preservation of prevalent control structure thanks to appropriate dissociation between slow and fast dynamics.©2019. CBIORE-IJRED. All rights reservedArticle History: Received Dec 8th 2017; Received in revised form July 16th 2018; Accepted December 15th 2018; Available onlineHow to Cite This Article: Yazdi, S.S.H., Milimonfared, J. and Fathi, S.H. (2019). Adaptation of VSC-HVDC Connected DFIG Based Offshore Wind Farm to Grid Codes: A Comparative Analysis. Int. Journal of Renewable Energy Development, 8(1), 91-101.https://doi.org/10.14710/ijred.8.1.91-101
Jaringan kolaborasi para penulis
3 penulis ·
3 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Amirkabir University of Technology Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulis Organisasi Artikel bersama
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Adaptation of VSC-HVDC Connected DFIG Based Offshore Wind Farm to Grid Codes: A Comparative Analysis</dc:title>
<dc:creator>Heidary Yazdi, Seyed Saed</dc:creator>
<dc:creator>Milimonfared, Jafar</dc:creator>
<dc:creator>Fathi, Seyed Hamid</dc:creator>
<dc:subject xml:lang="en-US">Grid codes, VSC-HVDC transmission line, offshore wind farm, doubly fed induction generator, voltage source converter, primary frequency response, inertial frequency response, fault ride through</dc:subject>
<dc:description xml:lang="en-US">Lack of synchronism between VSC-HVDC (Voltage Source Converter - High Voltage Direct Current) connected offshore wind farm and onshore grid leads to immunity of wind turbines to grid contingencies. Focusing on DFIG (Doubly Fed Induction Generator) based wind farms; this paper has presented a univalent control structure based on inertial and primary frequency response in which DC link voltage is utilized as synchronization interface. Based on the presented structure, four approaches based on the communication system, frequency, voltage and combined frequency and voltage modulation are utilized and compared to inform the onshore grid status to individual wind turbines. Considering Kondurs two area power system, results have revealed that all four approaches have similar ability (with negligible error) in offering inertial and primary frequency response to improve slow network oscillations. On the other hand, voltage and combined frequency and voltage modulation approaches have the ability to satisfy Fault Ride Through (FRT) requirements thanks to superior dynamics. However, communication and frequency modulation approaches lose that ability as communication and frequency measurement delays increase respectively. It has been concluded that combined frequency and voltage modulation, as the superior approach, has advantages like minimum FRT DC voltage profile increase and deviation from operating point after the fault, the minimum imposition of electrical and mechanical stress on DFIG and preservation of prevalent control structure thanks to appropriate dissociation between slow and fast dynamics.©2019. CBIORE-IJRED. All rights reservedArticle History: Received Dec 8th 2017; Received in revised form July 16th 2018; Accepted December 15th 2018; Available onlineHow to Cite This Article: Yazdi, S.S.H., Milimonfared, J. and Fathi, S.H. (2019). Adaptation of VSC-HVDC Connected DFIG Based Offshore Wind Farm to Grid Codes: A Comparative Analysis. Int. Journal of Renewable Energy Development, 8(1), 91-101.https://doi.org/10.14710/ijred.8.1.91-101</dc:description>
<dc:publisher xml:lang="en-US">Center of Biomass & Renewable Energy (CBIORE)</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2019-02-02</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/12841</dc:identifier>
<dc:identifier>10.14710/ijred.8.1.91-101</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 8, No 1 (2019): February 2019; 91-101</dc:source>
<dc:source>2252-4940</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/12841/pdf</dc:relation>
<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Heidary Yazdi, S. S., Milimonfared, J., & Fathi, S. H. (2019). Adaptation of VSC-HVDC Connected DFIG Based Offshore Wind Farm to Grid Codes: A Comparative Analysis. International Journal of Renewable Energy Development : JRED, 8(1), 91–101. https://doi.org/10.14710/ijred.8.1.91-101
Salin
IEEE
S. S. Heidary Yazdi, J. Milimonfared, and S. H. Fathi, “Adaptation of VSC-HVDC Connected DFIG Based Offshore Wind Farm to Grid Codes: A Comparative Analysis,” International Journal of Renewable Energy Development : JRED, vol. 8, no. 1, pp. 91–101, 2019, doi: 10.14710/ijred.8.1.91-101.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.