Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Advanced Loop Thermosiphon With Check Valve (ALT/CV): Thermal Performance and Behavior

International Journal of Renewable Energy Development : JRED · Vol. 10 No. 2 (2021) · hlm. 283–295

DOI
10.14710/ijred.2021.33805
ISSN
2252-4940
Terbit
2021-05-01
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Nanofluids (NFs) are an attractive alternative to traditional working fluids for thermosiphons, but the solid nanoparticles (NPs) within the NF can agglomerate and reduce the thermal performance. This study focused on clarifying the effect of a NF with surfactants on the heat transfer characteristics of an advanced loop thermosiphon with a check valve (ALT/CV). In an experiment, the ALT/CV was filled with different working fluids at filling ratios of 30%, 50%, and 80% with respect to the evaporator volume. Heat was supplied at 20%, 40%, 60%, 80%, and 100% of the heater output (2000 W). Five working fluids were considered: deionized (DI) water, a DI water-based NF with 0.5 wt% silver NPs, and the same NF containing 0.5, 1, and 1.5 wt% oleic acid (OA) and potassium oleate (OAK+) as surfactants. The results showed that the ALT/CV provided a better heat transfer performance than a normal thermosiphon. The maximum heat transfer rate was achieved with the NF containing 0.5 wt% silver NPs and 1 wt% OAK+. The NF containing OAK+ demonstrated a heat transfer rate approximately 80% higher than that of the DI water

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • King Mongkut's University of Technology North Bangkok
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Advanced Loop Thermosiphon With Check Valve (ALT/CV): Thermal Performance and Behavior</dc:title>
	<dc:creator>Booddachan, Khridsadakhon</dc:creator>
	<dc:creator>Bhuwakietkumjohn, Nipon</dc:creator>
	<dc:creator>Parameethanuwat, Thanya</dc:creator>
	<dc:subject xml:lang="en-US">Loop thermosyphon; Check value; Nanofluids; Surfactant; Potassium oleate</dc:subject>
	<dc:description xml:lang="en-US">Nanofluids (NFs) are an attractive alternative to traditional working fluids for thermosiphons, but the solid nanoparticles (NPs) within the NF can agglomerate and reduce the thermal performance. This study focused on clarifying the effect of a NF with surfactants on the heat transfer characteristics of an advanced loop thermosiphon with a check valve (ALT/CV). In an experiment, the ALT/CV was filled with different working fluids at filling ratios of 30%, 50%, and 80% with respect to the evaporator volume. Heat was supplied at 20%, 40%, 60%, 80%, and 100% of the heater output (2000 W). Five working fluids were considered: deionized (DI) water, a DI water-based NF with 0.5 wt% silver NPs, and the same NF containing 0.5, 1, and 1.5 wt% oleic acid (OA) and potassium oleate (OAK+) as surfactants. The results showed that the ALT/CV provided a better heat transfer performance than a normal thermosiphon. The maximum heat transfer rate was achieved with the NF containing 0.5 wt% silver NPs and 1 wt% OAK+. The NF containing OAK+ demonstrated a heat transfer rate approximately 80% higher than that of the DI water</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2021-05-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/33805</dc:identifier>
	<dc:identifier>10.14710/ijred.2021.33805</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 10, No 2 (2021): May 2021; 283-295</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/33805/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 The Authors. Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>