Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Improvement Approach for Matching PV-array and Inverter of Grid Connected PV Systems Verified by a Case Study

International Journal of Renewable Energy Development : JRED · Vol. 10 No. 4 (2021) · hlm. 687–697

DOI
10.14710/ijred.2021.36082
ISSN
2252-4940
Terbit
2021-11-01
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Correct matching between PV array and inverter improves the inverter efficiency, increases the annual produced energy, decreases the clipping losses of the inverter, and prevent to a large extent the inverter frequent shut downs during clear sunny days of high solar radiation and low ambient temperature. Therefore, this paper presents a new methodology for selecting the appropriate peak power of the PV array with respect to the inverter output AC rated power taking into account the local daily distribution of solar radiation and ambient temperature. In addition, the proposed methodology specifies the appropriate number of PV modules in each string and the number of parallel strings connected to the input of the inverteraccording to its specifications and to PV cell temperature. Mathematically modeling of system parameters and components are presented and used in the simulation to investigate the different scenarios. The paper presents also a case study using simulation to find the optimal matching parameters of a PV array connected to an inverter with the specifications: 6 kW rated output power, an input mpp voltage range of 333-500 V, 6.2 kW maximum input DC power, and an output AC voltage of 230 Vrms. Considering the local climate conditions in West Bank, the simulation resulted a peak power of 7 kW for the PV array, which is greater than the inverter output power by the factor 1.16. In addition, the obtained PV array consists of two parallel strings each includes 12 PV modules connected in series while each PV module is rated at 290 W. The output voltage of the PV arrayvaries between 359 V to 564 Vat minimum and maximum temperature of 10 ˚C to 70 ˚C respectively. This PV array-inverter combination resulted by simulation an annual yield of 1600 kWh/kWp and an energy of 11197 kWh which corresponds to an energy gain of 1591 kWh/year more than using a PV array with a peak power of 6 kW as the inverter rated power.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • An-Najah National University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Improvement Approach for Matching PV-array and Inverter of Grid Connected PV Systems Verified by a Case Study</dc:title>
	<dc:creator>Omar, Moien A.</dc:creator>
	<dc:creator>Mahmoud, Marwan M.</dc:creator>
	<dc:subject xml:lang="en-US">PV grid connected systems; PV inverters; PV array inverter sizing ratio; maximum power point; PV array configuration.</dc:subject>
	<dc:description xml:lang="en-US">Correct matching between PV array and inverter improves the inverter efficiency, increases the annual produced energy, decreases the clipping losses of the inverter, and prevent to a large extent the inverter frequent shut downs during clear sunny days of high solar radiation and low ambient temperature. Therefore, this paper presents a new methodology for selecting the appropriate peak power of the PV array with respect to the inverter output AC rated power taking into account the local daily distribution of solar radiation and ambient temperature. In addition, the proposed methodology specifies the appropriate number of PV modules in each string and the number of parallel strings connected to the input of the inverteraccording to its specifications and to PV cell temperature. Mathematically modeling of system parameters and components are presented and used in the simulation to investigate the different scenarios. The paper presents also a case study using simulation to find the optimal matching parameters of a PV array connected to an inverter with the specifications: 6 kW rated output power, an input mpp voltage range of 333-500 V, 6.2 kW maximum input DC power, and an output AC voltage of 230 Vrms. Considering the local climate conditions in West Bank, the simulation resulted a peak power of 7 kW for the PV array, which is greater than the inverter output power by the factor 1.16. In addition, the obtained PV array consists of two parallel strings each includes 12 PV modules  connected in series  while each PV module is rated at 290 W. The output voltage of the PV arrayvaries between 359 V to 564 Vat minimum and maximum temperature of 10 ˚C to 70 ˚C respectively. This PV array-inverter combination resulted by simulation an annual yield of 1600 kWh/kWp and an energy of 11197 kWh which corresponds to an energy gain of 1591 kWh/year more than using a PV array with a peak power of 6 kW as the inverter rated power.</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2021-11-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/36082</dc:identifier>
	<dc:identifier>10.14710/ijred.2021.36082</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 10, No 4 (2021): November 2021; 687-697</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/36082/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 The Authors. Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>