Akses terbuka
Jurnal
SINTA 1
Numerical Investigation of a Solar PV/T Air Collector Under the Climatic Conditions of Zarqa, Jordan
International Journal of Renewable Energy Development : JRED · Vol. 11 No. 4 (2022) · hlm. 963–972
ISSN 2252-4940
Terbit 2022-11-01
Penerbit Center of Biomass & Renewable Energy (CBIORE)
Bahasa eng
Abstrak
The use of hybrid photovoltaic/thermal (PV/T) and low concentrating photovoltaic/thermal (LCPV/T) systems can significantly enhance the overall solar energy conversion efficiency by delivering electricity and thermal energy. This paper presents a case study using a standing PV system's theoretical and modeling approach that can be modified to adapt to the hybrid technology. Firstly, a single-pass conventional PV/T air-cooled collector is investigated based on heat transfer and electrical models under the climatic conditions of Zarqa, Jordan. The performance parameters are evaluated using thermal and electrical properties of the considered PV installation and measured meteorological data. Results show that the total energy produced varies between a maximum of 134.6 kWh/m2 in July and a minimum of 81.7 kWh/m2 in January. The annual average hourly variation of overall energy efficiency ranges between 79.2% and 88.4%. Moreover, the dissipated thermal energy can meet 63.6% of the total energy required to ventilate the Hashemite University Presidency Building during the winter months. Finally, the performance of the modeled PV/T system air system coupled with flat boosters to provide a low irradiation concentration ratio (CR) is explored. The maximum electric output of the resulting LCPV/T system is compared with the uncooled system. It is found that the percentage improvement due to air cooling ranges between 0.72% at CR=1 and 2.77% at CR=2.5
Jaringan kolaborasi para penulis
7 penulis ·
12 tautan kepenulisan bersama
· 3 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Hashemite University Al Hussein Technical University
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Numerical Investigation of a Solar PV/T Air Collector Under the Climatic Conditions of Zarqa, Jordan</dc:title>
<dc:creator>Nijmeh, Salem</dc:creator>
<dc:creator>Bani Yaseen, Ahmad Ibrahim</dc:creator>
<dc:creator>Ashhab, Moh'd Sami</dc:creator>
<dc:creator>Juaidy, Mohammad</dc:creator>
<dc:subject xml:lang="en-US">PV/T air collector; Low concentration ratio; Numerical simulation; Useful thermal energy; Overall energy efficiency</dc:subject>
<dc:description xml:lang="en-US">The use of hybrid photovoltaic/thermal (PV/T) and low concentrating photovoltaic/thermal (LCPV/T) systems can significantly enhance the overall solar energy conversion efficiency by delivering electricity and thermal energy. This paper presents a case study using a standing PV system's theoretical and modeling approach that can be modified to adapt to the hybrid technology. Firstly, a single-pass conventional PV/T air-cooled collector is investigated based on heat transfer and electrical models under the climatic conditions of Zarqa, Jordan. The performance parameters are evaluated using thermal and electrical properties of the considered PV installation and measured meteorological data. Results show that the total energy produced varies between a maximum of 134.6 kWh/m2 in July and a minimum of 81.7 kWh/m2 in January. The annual average hourly variation of overall energy efficiency ranges between 79.2% and 88.4%. Moreover, the dissipated thermal energy can meet 63.6% of the total energy required to ventilate the Hashemite University Presidency Building during the winter months. Finally, the performance of the modeled PV/T system air system coupled with flat boosters to provide a low irradiation concentration ratio (CR) is explored. The maximum electric output of the resulting LCPV/T system is compared with the uncooled system. It is found that the percentage improvement due to air cooling ranges between 0.72% at CR=1 and 2.77% at CR=2.5</dc:description>
<dc:publisher xml:lang="en-US">Center of Biomass & Renewable Energy (CBIORE)</dc:publisher>
<dc:date>2022-11-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/45306</dc:identifier>
<dc:identifier>10.14710/ijred.2022.45306</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 11, No 4 (2022): November 2022; 963-972</dc:source>
<dc:source>2252-4940</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/45306/pdf</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2022 The Author(s). Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Nijmeh, S., Bani Yaseen, A. I., Ashhab, M. S., & Juaidy, M. (2022). Numerical Investigation of a Solar PV/T Air Collector Under the Climatic Conditions of Zarqa, Jordan. International Journal of Renewable Energy Development : JRED, 11(4), 963–972. https://doi.org/10.14710/ijred.2022.45306
Salin
IEEE
S. Nijmeh, A. I. Bani Yaseen, M. S. Ashhab, and M. Juaidy, “Numerical Investigation of a Solar PV/T Air Collector Under the Climatic Conditions of Zarqa, Jordan,” International Journal of Renewable Energy Development : JRED, vol. 11, no. 4, pp. 963–972, 2022, doi: 10.14710/ijred.2022.45306.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.