Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Optimization of Aeration for Accelerating Municipal Solid Waste Biodrying

International Journal of Renewable Energy Development : JRED · Vol. 11 No. 3 (2022) · hlm. 878–888

DOI
10.14710/ijred.2022.45143
ISSN
2252-4940
Terbit
2022-08-04
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Biodrying technology is commonly used in Thailand to produce refuse-derived fuel (RDF), however, this technology remains ineffective on high-moisture waste. Air supply is key to ensuring homogenous temperature development within the waste matrix during biodrying, increasing RDF quality. This study investigated negative aeration during local municipal solid waste biodrying to meet RDF standards in reduced time. Lysimeter experiments were performed on pre-shredded waste (300 kg/m3) using different aeration patterns. The temperature, vent gas oxygen level, weight loss, and leachate volume during the biodrying process were monitored. In addition, the treated waste’s temperature, moisture, and heating values were evaluated to determine the biodrying process efficiency. The results indicate that shorter heating phases can be achieved during continuous aeration. No significant temperature variation was observed in the waste layers, with a low standard deviation of 1.96% during constant air supply, indicating homogeneous temperature development during the biodrying process. The vent gas contained 15–20% oxygen and non-detectable methane, evidencing sufficient air supply. The total heat development was independent of aeration pattern; therefore, biodrying was unaffected by excess air supply at a 95% confidence level. The highest weight loss and moisture content reduction were 25% and 66%, respectively. The optimal aeration was continuous mode with non-excessive aeration, increasing the lower heating value from 2,884.0 to 4,938.0 kCal/kg, and reducing the moisture content from 48.5% to 22.2%. RDF quality can be improved 1.7 times to meet Thailand’s standards within a short biodrying period of 7 days using homogeneous temperature distribution operated under continuous aeration

Kata kunci

Jaringan kolaborasi para penulis

17 penulis · 48 tautan kepenulisan bersama · 21 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Joint Graduate School of Energy and Environment
  • Kasetsart University
  • Sriwijaya University
  • King Mongkut's University of Technology North Bangkok
  • Mae Fah Luang University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Tanik ItsarathornJoint Graduate School of Energy and Environment4
Awassada PhongphiphatJoint Graduate School of Energy and Environment4
Abhisit BhatsadaJoint Graduate School of Energy and Environment4
Eka WahyantiJoint Graduate School of Energy and Environment3
Noppharit SutthasilMae Fah Luang University3
Bazlina Dawami AfrahSriwijaya University1
Muhammad IqbalAfiliasi tidak diketahui1
Muhammad Geo FarandSriwijaya University1
M. Ibnus SyabilSriwijaya University1
Wilai ChiemchaisriKasetsart University1
Sujipat DachsrijanKasetsart University1
Chitsuphang SaengamKasetsart University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Optimization of Aeration for Accelerating Municipal Solid Waste Biodrying</dc:title>
	<dc:creator>Payomthip, Panida</dc:creator>
	<dc:creator>Towprayoon, Sirintornthep</dc:creator>
	<dc:creator>Chiemchaisri, Chart</dc:creator>
	<dc:creator>Patumsawad, Suthum</dc:creator>
	<dc:creator>Wangyao, Komsilp</dc:creator>
	<dc:subject xml:lang="en-US">Biodrying; mechanical biological treatment; municipal solid waste; negative aeration; refuse-derived fuel</dc:subject>
	<dc:description xml:lang="en-US">Biodrying technology is commonly used in Thailand to produce refuse-derived fuel (RDF), however, this technology remains ineffective on high-moisture waste. Air supply is key to ensuring homogenous temperature development within the waste matrix during biodrying, increasing RDF quality. This study investigated negative aeration during local municipal solid waste biodrying to meet RDF standards in reduced time. Lysimeter experiments were performed on pre-shredded waste (300 kg/m3) using different aeration patterns. The temperature, vent gas oxygen level, weight loss, and leachate volume during the biodrying process were monitored. In addition, the treated waste’s temperature, moisture, and heating values were evaluated to determine the biodrying process efficiency. The results indicate that shorter heating phases can be achieved during continuous aeration. No significant temperature variation was observed in the waste layers, with a low standard deviation of 1.96% during constant air supply, indicating homogeneous temperature development during the biodrying process. The vent gas contained 15–20% oxygen and non-detectable methane, evidencing sufficient air supply. The total heat development was independent of aeration pattern; therefore, biodrying was unaffected by excess air supply at a 95% confidence level. The highest weight loss and moisture content reduction were 25% and 66%, respectively. The optimal aeration was continuous mode with non-excessive aeration, increasing the lower heating value from 2,884.0 to 4,938.0 kCal/kg, and reducing the moisture content from 48.5% to 22.2%. RDF quality can be improved 1.7 times to meet Thailand’s standards within a short biodrying period of 7 days using homogeneous temperature distribution operated under continuous aeration</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2022-08-04</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/45143</dc:identifier>
	<dc:identifier>10.14710/ijred.2022.45143</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 11, No 3 (2022): August 2022; 878-888</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>info:eu-repo/grantAgreement/EC/FP7/615001</dc:relation>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/45143/pdf</dc:relation>
	<dc:rights xml:lang="en-US">info:eu-repo/semantics/openAccess</dc:rights>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 The Author(s). Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>