Techno-Economic Assessment of a 100 kWp Solar Rooftop PV System for Five Hospitals in Central Southern Thailand

International Journal of Renewable Energy Development : JRED · Vol. 12 No. 1 (2023) · hlm. 77–86

DOI
10.14710/ijred.2023.46864
ISSN
2252-4940
Terbit
2023-01-01
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper presents a techno-economic assessment of a 100 kWp solar rooftop photovoltaic (PV) system at five hospitals in central southern Thailand. The system encompasses 100 kWp PV panels, 100 kW grid-tied inverters and balance of system (BOS) under the grid code of the Provincial Electricity Authority (PEA). The latest PV technology of bifacial mono-crystalline solar panels, inverters and BOS were simulated along with the Meteonorm 7.3 database using the PVsyst simulation toolkit with different tilt angles, orientations, solar radiations and ambient temperature. The technical aspects of solar rooftop PV power generation systems include the annual energy output and the performance ratio (PR) under IEC standard. Further, an economic analysis of the model was examined using a cost benefit analysis (CBA) and various assumptions. Four main financial criteria, i.e., benefit cost ratio (BCR), net present value (NPV), internal rate of return (IRR), and payback period (PBP) were evaluated under three different scenarios: (1) self-consumption scheme, (2) feed-in tariff (FiT) scheme, and (3) private power purchase agreement (PPA) scheme. Finally, the levelized cost of energy (LCOE) was also calculated. The results reveal that the Takua Thung hospital is characterized by the maximum average global horizontal irradiation (GHI) and the maximum annual produced energy of 199 kWh/m2 and 164.8 MWh/year, respectively. The PR calculated for all hospital sites is above 85%. The outcomes of the financial analysis show that the optimum scenarios are PPA and FiT schemes. The LCOE analysed in this study indicates that the Takua Thung hospital site has the lowest LCOE at 2.47 THB/kWh (0.07 USD/kWh). This research confirms the potential for hospitals and stakeholders in central southern Thailand for investments in solar rooftop PV systems

Kata kunci

Jaringan kolaborasi para penulis

9 penulis · 34 tautan kepenulisan bersama · 26 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Thaksin University
  • Nakhon Si Thammarat Rajabhat University
  • Walailak University
  • Université de Moncton
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Weerasak ChaichanThaksin University6
Sakrapee KhunpetchNakhon Si Thammarat Rajabhat University6

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Techno-Economic Assessment of a 100 kWp Solar Rooftop PV System for Five Hospitals in Central Southern Thailand</dc:title>
	<dc:creator>Khamharnphol, Rawit</dc:creator>
	<dc:creator>Kamdar, Ismail</dc:creator>
	<dc:creator>Waewsak, Jompob</dc:creator>
	<dc:creator>Chiwamongkhonkarn, Somphol</dc:creator>
	<dc:creator>Khunpetcha, Sakrapee</dc:creator>
	<dc:creator>Kongruang, Chuleerat</dc:creator>
	<dc:creator>Gagnon, Yves</dc:creator>
	<dc:subject xml:lang="en-US">Solar Rooftop PV; Bifacial Photovoltaic; Performance Ratio; Levelized Cost of Energy; Economic Analysis.</dc:subject>
	<dc:description xml:lang="en-US">This paper presents a techno-economic assessment of a 100 kWp solar rooftop photovoltaic (PV) system at five hospitals in central southern Thailand.  The system encompasses 100 kWp PV panels, 100 kW grid-tied inverters and balance of system (BOS) under the grid code of the Provincial Electricity Authority (PEA).  The latest PV technology of bifacial mono-crystalline solar panels, inverters and BOS were simulated along with the Meteonorm 7.3 database using the PVsyst simulation toolkit with different tilt angles, orientations, solar radiations and ambient temperature.  The technical aspects of solar rooftop PV power generation systems include the annual energy output and the performance ratio (PR) under IEC standard.  Further, an economic analysis of the model was examined using a cost benefit analysis (CBA) and various assumptions.  Four main financial criteria, i.e., benefit cost ratio (BCR), net present value (NPV), internal rate of return (IRR), and payback period (PBP) were evaluated under three different scenarios: (1) self-consumption scheme, (2) feed-in tariff (FiT) scheme, and (3) private power purchase agreement (PPA) scheme.  Finally, the levelized cost of energy (LCOE) was also calculated.  The results reveal that the Takua Thung hospital is characterized by the maximum average global horizontal irradiation (GHI) and the maximum annual produced energy of 199 kWh/m2 and 164.8 MWh/year, respectively.  The PR calculated for all hospital sites is above 85%. The outcomes of the financial analysis show that the optimum scenarios are PPA and FiT schemes.  The LCOE analysed in this study indicates that the Takua Thung hospital site has the lowest LCOE at 2.47 THB/kWh (0.07 USD/kWh).  This research confirms the potential for hospitals and stakeholders in central southern Thailand for investments in solar rooftop PV systems</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2023-01-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/46864</dc:identifier>
	<dc:identifier>10.14710/ijred.2023.46864</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 12, No 1 (2023): January 2023; 77-86</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/46864/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 The Author(s). Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>