Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Optimizing solar dish performance using analytical flux distribution in focal region

International Journal of Renewable Energy Development : JRED · Vol. 9 No. 1 (2020) · hlm. 63–67

DOI
10.14710/ijred.9.1.63-67
ISSN
2252-4940
Terbit
2020-02-18
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by/4.0

Abstrak

In this paper, thermal performance analysis of 4 m2 solar dish collector is presented.The focal image characteristics of the solar dish are determined to propose the suitable design of a receiver. A flat plate was used for the receiver to measure flux distribution in the focal region. The measurement had been done in the midday. Intercept factor based on this distribution had been calculated and was obtained to calculate thermal efficiency after total heat loss was described. From the experiment, total heat loss was formed by conductive and radiative in the receiver. The results showed that the increase in total heat loss followed the increase in receiver temperature and it caused a decrease in thermal efficiency. On the peak of the measurement or in midday, receiver temperature can achieve 138°C and it gave around 1200-Watt heat loss and it was dominated by radiative heat loss for around 80%. The thermal efficiency of the system due to flux distribution measurement in the focal region was above 70% and it was classified as high average but we needed to cover this flux up so it did not lose a lot of heat. Cavity aperture would keep around 20% total heat loss and it minimized radiative heat loss from the flux. The design of cavity aperture was the next discussion to insulate thermal heat reflection of the parabolic dish system from high radiative heat loss.©2020. CBIORE-IJRED. All rights reserved

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 9 tautan kepenulisan bersama · 8 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Politeknik Perkapalan Negeri Surabaya
  • Institut Teknologi Sepuluh Nopember
  • Universitas Negeri Surabaya
  • Universitas Dayanu Ikhsanuddin
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Prabowo PrabowoInstitut Teknologi Sepuluh Nopember2
Bambang AntokoPoliteknik Perkapalan Negeri Surabaya2
Dedy AshariUniversitas Dayanu Ikhsanuddin1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Optimizing solar dish performance using analytical flux distribution in focal region</dc:title>
	<dc:creator>Santoso, Dany Iman</dc:creator>
	<dc:creator>Antoko, Bambang</dc:creator>
	<dc:creator>Ichsani, Djatmiko</dc:creator>
	<dc:subject xml:lang="en-US">dish collector; focal region; receiver; flux distribution; intercept factor</dc:subject>
	<dc:description xml:lang="en-US">In this paper, thermal performance analysis of 4 m2 solar dish collector is presented.The focal image characteristics of the solar dish are determined to propose the suitable design of a receiver. A flat plate was used for the receiver to measure flux distribution in the focal region. The measurement had been done in the midday. Intercept factor based on this distribution had been calculated and was obtained to calculate thermal efficiency after total heat loss was described. From the experiment, total heat loss was formed by conductive and radiative in the receiver. The results showed that the increase in total heat loss followed the increase in receiver temperature and it caused a decrease in thermal efficiency. On the peak of the measurement or in midday, receiver temperature can achieve 138°C and it gave around 1200-Watt heat loss and it was dominated by radiative heat loss for around 80%. The thermal efficiency of the system due to flux distribution measurement in the focal region was above 70% and it was classified as high average but we needed to cover this flux up so it did not lose a lot of heat. Cavity aperture would keep around 20% total heat loss and it minimized radiative heat loss from the flux. The design of cavity aperture was the next discussion to insulate thermal heat reflection of the parabolic dish system from high radiative heat loss.©2020. CBIORE-IJRED. All rights reserved</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2020-02-18</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/27111</dc:identifier>
	<dc:identifier>10.14710/ijred.9.1.63-67</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 9, No 1 (2020): February 2020; 63-67</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/27111/pdf</dc:relation>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by/4.0</dc:rights>
</oai_dc:dc>