Optimum Control of Grid-Connected Solar Power System Under Asymmetrical Voltage Drop
International Journal of Renewable Energy Development : JRED · Vol. 11 No. 3 (2022) · hlm. 789–800
ISSN 2252-4940
Terbit 2022-08-04
Penerbit Center of Biomass & Renewable Energy (CBIORE)
Bahasa eng
Abstrak
Solar power systems are now gradually dominating in providing clean, environmentally friendly energy and human health. In areas with a large share of solar power, grid connection control plays a key role in ensuring operational quality and stability, especially in the event of a grid failure. In case of asymmetrical voltage drop, the control system needs to maintain operation and create a function to assist in restoring the power grid. This study proposes a method to control the solar power system in the condition of asymmetric grid voltage drop based on the method of controlling symmetrical components. Controllers for each of the forward and inverse components are built to limit the effects of failures. The optimal control parameter calculation method is also proposed to improve the overall quality and minimize the undesired variation of the electromagnetic quantities. The simulation and experimental results are verified to evaluate the effectiveness of the grid-connected control method in converting DC power to three-phase power.
Jaringan kolaborasi para penulis
2 penulis ·
1 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Vietnam National University Ho Chi Minh City Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulis Organisasi Artikel bersama
Trinh Phu Duy Afiliasi tidak diketahui 1
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Optimum Control of Grid-Connected Solar Power System Under Asymmetrical Voltage Drop</dc:title>
<dc:creator>Nguyen, Van Binh</dc:creator>
<dc:subject xml:lang="en-US">Solar power; Grid connection control; Grid disturbance; Symmetrical component; Inverse sequence controller</dc:subject>
<dc:description xml:lang="en-US">Solar power systems are now gradually dominating in providing clean, environmentally friendly energy and human health. In areas with a large share of solar power, grid connection control plays a key role in ensuring operational quality and stability, especially in the event of a grid failure. In case of asymmetrical voltage drop, the control system needs to maintain operation and create a function to assist in restoring the power grid. This study proposes a method to control the solar power system in the condition of asymmetric grid voltage drop based on the method of controlling symmetrical components. Controllers for each of the forward and inverse components are built to limit the effects of failures. The optimal control parameter calculation method is also proposed to improve the overall quality and minimize the undesired variation of the electromagnetic quantities. The simulation and experimental results are verified to evaluate the effectiveness of the grid-connected control method in converting DC power to three-phase power.</dc:description>
<dc:publisher xml:lang="en-US">Center of Biomass & Renewable Energy (CBIORE)</dc:publisher>
<dc:date>2022-08-04</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/45115</dc:identifier>
<dc:identifier>10.14710/ijred.2022.45115</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 11, No 3 (2022): August 2022; 789-800</dc:source>
<dc:source>2252-4940</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/45115/pdf</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2022 The Author(s). Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Nguyen, V. B. (2022). Optimum Control of Grid-Connected Solar Power System Under Asymmetrical Voltage Drop. International Journal of Renewable Energy Development : JRED, 11(3), 789–800. https://doi.org/10.14710/ijred.2022.45115
Salin
IEEE
V. B. Nguyen, “Optimum Control of Grid-Connected Solar Power System Under Asymmetrical Voltage Drop,” International Journal of Renewable Energy Development : JRED, vol. 11, no. 3, pp. 789–800, 2022, doi: 10.14710/ijred.2022.45115.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.