Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Mathematical model to evaluate the effect of key operating conditions on proton exchange membrane fuel cell performance

International Journal of Renewable Energy Development : JRED · Vol. 15 No. 5 (2026) · hlm. 909–922

DOI
10.61435/ijred.2026.62184
ISSN
2252-4940
Terbit
2026-09-01
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Nowadays, proton exchange membrane fuel cells (PEMFCs) are regarded as a promising energy source for future applications due to their relatively low operating temperature, high efficiency, high power density, fast start-up capability, and zero emissions. During PEMFC operation, performance is influenced by numerous factors, including the key operating conditions. Therefore, developing a mathematical model to evaluate the effects of key operating conditions on PEMFC performance and energy efficiency is both necessary and significant in the PEMFCs. In this study, a mathematical model was developed using MATLAB/Simulink software and subsequently validated through a series of experiments to assess its accuracy. The results demonstrate that PEMFC performance is strongly affected by operating conditions, including operating temperature, operating pressure, membrane thickness, cathode gas type, cell active area, and the number of cells in the stack. In addition, water, heat generation, energy efficiency, and gas consumption were also considered and discussed detailed in the model. The findings indicate that operating temperature and pressure are the most influential parameters affecting PEMFC performance and energy efficiency. When the operating temperature increased, the cell performance improved due to enhanced electrochemical reaction kinetics and improved electrical conductivity. However, when the PEMFC operates at temperatures above 70 oC, a deterioration in performance is observed. This behavior can be attributed to membrane dehydration at elevated temperatures, which reduces proton conductivity and, consequently, lowers the output cell voltage. Increasing pressure reduces membrane resistance and interface contact resistance, leading to a decrease in voltage losses and an improvement in cell voltage. Therefore, the optimal operating tempearature was achieved at 70 oC in this study. At a current density of 0.5 A cm−2, the cell voltages are 0.550, 0.559, 0.564, 0.568, 0.571, and 0.574 V for anode operating pressures of 1.0, 1.5, 2.0, 2.5, 3.0, and 3.5 atm, respectively. Overall, this study provides a reliable and precise tool for predicting PEMFC performance under varying operating conditions.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 8 tautan kepenulisan bersama · 4 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Lac Hong University
  • Ho Chi Minh City University of Technology and Engineering
  • King Mongkut's Institute of Technology Ladkrabang
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Tan-Ngoc DinhHo Chi Minh City University of Technology and Engineering2
Ly Vinh DatHo Chi Minh City University of Technology and Engineering2
Phuoc-Dong DoanKing Mongkut's Institute of Technology Ladkrabang2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Mathematical model to evaluate the effect of key operating conditions on proton exchange membrane fuel cell performance</dc:title>
	<dc:creator>Do, Tan-Thich</dc:creator>
	<dc:creator>Vi, Trung-Kien</dc:creator>
	<dc:creator>Pham, Cong-Son</dc:creator>
	<dc:subject xml:lang="en-US">Proton exchange membrane fuel cell; Fuel cell voltage; Fuel cell power; Energy efficiency; Water generation; Heat generation; Hydrogen utilization; Oxygen utilization.</dc:subject>
	<dc:description xml:lang="en-US">Nowadays, proton exchange membrane fuel cells (PEMFCs) are regarded as a promising energy source for future applications due to their relatively low operating temperature, high efficiency, high power density, fast start-up capability, and zero emissions. During PEMFC operation, performance is influenced by numerous factors, including the key operating conditions. Therefore, developing a mathematical model to evaluate the effects of key operating conditions on PEMFC performance and energy efficiency is both necessary and significant in the PEMFCs. In this study, a mathematical model was developed using MATLAB/Simulink software and subsequently validated through a series of experiments to assess its accuracy. The results demonstrate that PEMFC performance is strongly affected by operating conditions, including operating temperature, operating pressure, membrane thickness, cathode gas type, cell active area, and the number of cells in the stack. In addition, water, heat generation, energy efficiency, and gas consumption were also considered and discussed detailed in the model. The findings indicate that operating temperature and pressure are the most influential parameters affecting PEMFC performance and energy efficiency. When the operating temperature increased, the cell performance improved due to enhanced electrochemical reaction kinetics and improved electrical conductivity. However, when the PEMFC operates at temperatures above 70 oC, a deterioration in performance is observed. This behavior can be attributed to membrane dehydration at elevated temperatures, which reduces proton conductivity and, consequently, lowers the output cell voltage. Increasing pressure reduces membrane resistance and interface contact resistance, leading to a decrease in voltage losses and an improvement in cell voltage. Therefore, the optimal operating tempearature was achieved at 70 oC in this study. At a current density of 0.5 A cm−2, the cell voltages are 0.550, 0.559, 0.564, 0.568, 0.571, and 0.574 V for anode operating pressures of 1.0, 1.5, 2.0, 2.5, 3.0, and 3.5 atm, respectively. Overall, this study provides a reliable and precise tool for predicting PEMFC performance under varying operating conditions.</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2026-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/62184</dc:identifier>
	<dc:identifier>10.61435/ijred.2026.62184</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 15, No 5 (2026): September 2026; 909-922</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/62184/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 The Author(s). Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>