Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Theoretical study of a double-slope solar still with solar air heater condenser

International Journal of Renewable Energy Development : JRED · Vol. 12 No. 6 (2023) · hlm. 977–986

DOI
10.14710/ijred.2023.53928
ISSN
2252-4940
Terbit
2023-11-01
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Despite their limited water production and efficiency, double-slope solar stills are an appropriate solution for water scarcity in hot arid regions. Numerous studies have focused on enhancing the effectiveness of double-slope solar stills. In this context, this study introduces a double-slope solar with a solar air heater condenser (DSSS-SAHC). The back cover of a conventional double-slope solar still was replaced by a glass air heater in order to recover the still’s thermal losses in heating air. The transient performance of the DSSS-SAHC was investigated numerically under real weather conditions and compared to the performance of a conventional double-slope solar still (CDSSS) with the same aspects. The impact of various weather and operation factors on the DSSS-SAHC performance was investigated at air flows of 0.01 and 0.1 kg/s to account for both natural and forced air circulation, respectively. The results revealed an increase of about 15% and 6% in the thermal efficiency of the DSSS-SAHC over that of the CDSSS, respectively, at air flows of 0.1 and 0.01 kg/s despite the DSSS-SAHC distillate was insignificantly greater than that of the CDSSS at both air flows. In addition, the water distillate of the DSSS-SAHC increased as the solar irradiance increased, the ambient wind and ambient temperature had contrary effects on the efficiency, and the initial saline water level had a negligible impact on the overall performance

Kata kunci

Jaringan kolaborasi para penulis

Belum ada rekan penulis di Melola.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Theoretical study of a double-slope solar still with solar air heater condenser</dc:title>
	<dc:creator>Ghazy, Ahmed</dc:creator>
	<dc:subject xml:lang="en-US">Double-slope; Solar still; Solar air heater; Thermal performance</dc:subject>
	<dc:description xml:lang="en-US">Despite their limited water production and efficiency, double-slope solar stills are an appropriate solution for water scarcity in hot arid regions. Numerous studies have focused on enhancing the effectiveness of double-slope solar stills. In this context, this study introduces a double-slope solar with a solar air heater condenser (DSSS-SAHC). The back cover of a conventional double-slope solar still was replaced by a glass air heater in order to recover the still’s thermal losses in heating air. The transient performance of the DSSS-SAHC was investigated numerically under real weather conditions and compared to the performance of a conventional double-slope solar still (CDSSS) with the same aspects. The impact of various weather and operation factors on the DSSS-SAHC performance was investigated at air flows of 0.01 and 0.1 kg/s to account for both natural and forced air circulation, respectively. The results revealed an increase of about 15% and 6% in the thermal efficiency of the DSSS-SAHC over that of the CDSSS, respectively, at air flows of 0.1 and 0.01 kg/s despite the DSSS-SAHC distillate was insignificantly greater than that of the CDSSS at both air flows. In addition, the water distillate of the DSSS-SAHC increased as the solar irradiance increased, the ambient wind and ambient temperature had contrary effects on the efficiency, and the initial saline water level had a negligible impact on the overall performance</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2023-11-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/53928</dc:identifier>
	<dc:identifier>10.14710/ijred.2023.53928</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 12, No 6 (2023): November 2023; 977-986</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/53928/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 The Author(s). Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>