Two-Phase Expander Approach for Next Generation of Heat Recovery Systems
International Journal of Renewable Energy Development : JRED · Vol. 8 No. 3 (2019) · hlm. 203–213
ISSN 2252-4940
Terbit 2019-10-27
Penerbit Center of Biomass & Renewable Energy (CBIORE)
Bahasa eng
Abstrak
This study presents the numerical adaptations to the semi-empirical expander model in order to examine the feasibility of piston expanders under off-design and two-phase scenarios. This expander model considers supply valve pressure drop, condensation phenomena, heat losses, leakage losses and friction losses. Using Aspen HYSYS©, the expander model is utilised in simulating the next generation of integrated engine cooling and exhaust heat recovery system for future heavy-duty engines. The heat recovery system utilises water-propanol working fluid mixture and consists of independent high pressure (HP) and low pressure (LP) expander. The results of off‑design and two-phase operation are presented in terms of expander efficiency and the different sources of loss, under two distinctive engine speed-load conditions. The heat recovery system, operating with the LP expander at two-phase and the HP expander at superheated condition, represented the design point condition. At the design point, the system provided 15.9 kW of net power, with an overall conversion efficiency of 11.4%, representing 10% of additional engine crankshaft power. At the extreme off-design condition, the two-phase expander operation improved the system performance as a result of the nullification of leakage losses due to the much denser working fluid. The optimised two-phase operation of the LP expander (x=0.55) and the HP expander (x=0.9) at the extreme-off design condition improved the system power by nearly 50% (17.4 vs. 11.7 kW) compared to the reference state. Finally, adapting piston air motors as two-phase expanders for experimental evaluation and reduction in frictional losses was a recommended research direction. ©2019. CBIORE-IJRED. All rights reserved
Jaringan kolaborasi para penulis
2 penulis ·
1 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulis Organisasi Artikel bersama
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Two-Phase Expander Approach for Next Generation of Heat Recovery Systems</dc:title>
<dc:creator>Panesar, Angad S</dc:creator>
<dc:creator>Bernagozzi, Marco</dc:creator>
<dc:subject xml:lang="en-US">Two-Phase; Waste Heat Recovery; Piston Expander; Friction; Heat Transfer</dc:subject>
<dc:description xml:lang="en-US">This study presents the numerical adaptations to the semi-empirical expander model in order to examine the feasibility of piston expanders under off-design and two-phase scenarios. This expander model considers supply valve pressure drop, condensation phenomena, heat losses, leakage losses and friction losses. Using Aspen HYSYS©, the expander model is utilised in simulating the next generation of integrated engine cooling and exhaust heat recovery system for future heavy-duty engines. The heat recovery system utilises water-propanol working fluid mixture and consists of independent high pressure (HP) and low pressure (LP) expander. The results of off‑design and two-phase operation are presented in terms of expander efficiency and the different sources of loss, under two distinctive engine speed-load conditions. The heat recovery system, operating with the LP expander at two-phase and the HP expander at superheated condition, represented the design point condition. At the design point, the system provided 15.9 kW of net power, with an overall conversion efficiency of 11.4%, representing 10% of additional engine crankshaft power. At the extreme off-design condition, the two-phase expander operation improved the system performance as a result of the nullification of leakage losses due to the much denser working fluid. The optimised two-phase operation of the LP expander (x=0.55) and the HP expander (x=0.9) at the extreme-off design condition improved the system power by nearly 50% (17.4 vs. 11.7 kW) compared to the reference state. Finally, adapting piston air motors as two-phase expanders for experimental evaluation and reduction in frictional losses was a recommended research direction. ©2019. CBIORE-IJRED. All rights reserved</dc:description>
<dc:publisher xml:lang="en-US">Center of Biomass & Renewable Energy (CBIORE)</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2019-10-27</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/26138</dc:identifier>
<dc:identifier>10.14710/ijred.8.3.203-213</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 8, No 3 (2019): October 2019; 203-213</dc:source>
<dc:source>2252-4940</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/26138/pdf</dc:relation>
<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Panesar, A. S., & Bernagozzi, M. (2019). Two-Phase Expander Approach for Next Generation of Heat Recovery Systems. International Journal of Renewable Energy Development : JRED, 8(3), 203–213. https://doi.org/10.14710/ijred.8.3.203-213
Salin
IEEE
A. S. Panesar and M. Bernagozzi, “Two-Phase Expander Approach for Next Generation of Heat Recovery Systems,” International Journal of Renewable Energy Development : JRED, vol. 8, no. 3, pp. 203–213, 2019, doi: 10.14710/ijred.8.3.203-213.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.