Akses terbuka
Jurnal
SINTA 1
Effect of Fluid Flow Direction on Charging of Multitube Thermal Energy Storage for Flat Plate Solar Collectors
International Journal of Renewable Energy Development : JRED · Vol. 10 No. 2 (2021) · hlm. 365–371
ISSN 2252-4940
Terbit 2021-05-01
Penerbit Center of Biomass & Renewable Energy (CBIORE)
Bahasa eng
Abstrak
Flat plate solar collector plays a significant role in domestic water heating due to the ease of operation and maintenance. Thermal energy storage with phase change materials is used to store heat energy. The thermal performance of paraffin wax-based multitube latent heat storage with a flat plate solar collector is investigated experimentally. The present work focuses on the fluid flow direction for charging and discharging in a vertical multitube-based thermal storage unit. The charging process took about four hours, with a fluid flow rate of 0.02 kg/s at about 70°C. The flat plate solar collector's thermal efficiency is 56.42% for the fluid flow rate of 0.02 kg/s at the average solar radiation of about 600 W/m2. During the discharge process, there was an increase in water temperature by 40°C at a fluid flow rate of 0.01 kg/s in 30 minutes. The 25-liters of water is circulated to discharge the stored heat. The heat storage effectiveness is varied between about 0.4 and 0.75. During the discharge, the flow of water from the center to the periphery showed about a 1.7% higher temperature than that of the water from the periphery to the center. For charging the heat storage, the preferred fluid flow mode is from the periphery to the center. The employment of latent heat storage with a solar collector is beneficial for our thermal needs after sunshine hours.
Jaringan kolaborasi para penulis
11 penulis ·
22 tautan kepenulisan bersama
· 12 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
SRM Institute of Science and Technology National Institute of Technology Tiruchirappalli Anna University, Chennai University of Washington Delft University of Technology KTH Royal Institute of Technology Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Effect of Fluid Flow Direction on Charging of Multitube Thermal Energy Storage for Flat Plate Solar Collectors</dc:title>
<dc:creator>Senthil, Ramalingam</dc:creator>
<dc:subject xml:lang="en-US">Thermal energy storage; solar energy; phase change material; charging process; heat transfer fluid; flat plate solar collector.</dc:subject>
<dc:description xml:lang="en-US">Flat plate solar collector plays a significant role in domestic water heating due to the ease of operation and maintenance. Thermal energy storage with phase change materials is used to store heat energy. The thermal performance of paraffin wax-based multitube latent heat storage with a flat plate solar collector is investigated experimentally. The present work focuses on the fluid flow direction for charging and discharging in a vertical multitube-based thermal storage unit. The charging process took about four hours, with a fluid flow rate of 0.02 kg/s at about 70°C. The flat plate solar collector's thermal efficiency is 56.42% for the fluid flow rate of 0.02 kg/s at the average solar radiation of about 600 W/m2. During the discharge process, there was an increase in water temperature by 40°C at a fluid flow rate of 0.01 kg/s in 30 minutes. The 25-liters of water is circulated to discharge the stored heat. The heat storage effectiveness is varied between about 0.4 and 0.75. During the discharge, the flow of water from the center to the periphery showed about a 1.7% higher temperature than that of the water from the periphery to the center. For charging the heat storage, the preferred fluid flow mode is from the periphery to the center. The employment of latent heat storage with a solar collector is beneficial for our thermal needs after sunshine hours.</dc:description>
<dc:publisher xml:lang="en-US">Center of Biomass & Renewable Energy (CBIORE)</dc:publisher>
<dc:date>2021-05-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/34931</dc:identifier>
<dc:identifier>10.14710/ijred.2021.34931</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 10, No 2 (2021): May 2021; 365-371</dc:source>
<dc:source>2252-4940</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/34931/pdf</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2021 The Authors. Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Senthil, R. (2021). Effect of Fluid Flow Direction on Charging of Multitube Thermal Energy Storage for Flat Plate Solar Collectors. International Journal of Renewable Energy Development : JRED, 10(2), 365–371. https://doi.org/10.14710/ijred.2021.34931
Salin
IEEE
R. Senthil, “Effect of Fluid Flow Direction on Charging of Multitube Thermal Energy Storage for Flat Plate Solar Collectors,” International Journal of Renewable Energy Development : JRED, vol. 10, no. 2, pp. 365–371, 2021, doi: 10.14710/ijred.2021.34931.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.