Energy and exergy performance of a solar-driven NH₃–NaSCN absorption refrigeration cycle: Case study in the Colombian Caribbean

International Journal of Renewable Energy Development : JRED · Vol. 15 No. 2 (2026) · hlm. 358–371

DOI
10.61435/ijred.2026.61668
ISSN
2252-4940
Terbit
2026-03-01
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Absorption refrigeration systems are increasingly recognized as sustainable alternatives for cooling applications, particularly when integrated with renewable energy sources such as solar thermal systems. Among the available working pairs, the NH₃–NaSCN solution offers favorable thermodynamic properties and low environmental impact; however, its performance under tropical climatic conditions with solar integration remains insufficiently explored. This study evaluates the thermodynamic and exergetic performance of a single-effect NH₃–NaSCN absorption refrigeration cycle integrated with a flat-plate solar collector, considering the climatic conditions of five cities of the Colombian Caribbean Region. A validated thermodynamic model was applied to assess the influence of generator, condenser, absorber, and evaporator temperatures on the coefficient of performance (COP) and exergetic efficiency. Results show that increasing generator temperature from 75 °C to 120 °C enhances COP by up to 46.15 %, while raising the evaporator temperature from –8 °C to 4 °C improves COP by 16 %. Conversely, increasing condenser and absorber temperatures reduce COP by 20.54 % and 16 %, respectively. Exergy destruction analysis indicates that the generator and absorber account for 55 % and 34 % of total irreversibilities, highlighting them as priority targets for optimization. Analysis of variance identified generator temperature as the most influential parameter on COP (39.37 %), followed by condenser (31.22 %) and evaporator temperatures (15.18 %). Solar integration enabled stable operation with an average COP decrease of only 3 % across the five cities; however, the use of water in the solar collector restricted operation below the optimal efficiency range (95–120 °C). The combined performance index integrating COP and exergetic efficiency showed that the operating range characterized by elevated generator temperature and reduced condenser temperature delivers the best energy–exergy trade-off, providing design guidelines for high-irradiance regions and supporting the adoption of NH₃–NaSCN as a cost-effective, renewable refrigeration solution.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 15 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universidad de la Costa
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Energy and exergy performance of a solar-driven NH₃–NaSCN absorption refrigeration cycle: Case study in the Colombian Caribbean</dc:title>
	<dc:creator>Carval-García, Vanessa</dc:creator>
	<dc:creator>Sabalza-Pérez, Daniela</dc:creator>
	<dc:creator>Caratt-Ortiz, Jean</dc:creator>
	<dc:creator>De Armas-Calderón, Nelly</dc:creator>
	<dc:creator>Rodríguez-Toscano, Andrés</dc:creator>
	<dc:creator>Anguiano-González, Howen</dc:creator>
	<dc:subject xml:lang="en-US">Absorption refrigeration system; NH₃–NaSCN; exergy analysis; solar thermal integration; energy–exergy optimization; Ammonia–sodium thiocyanate</dc:subject>
	<dc:description xml:lang="en-US">Absorption refrigeration systems are increasingly recognized as sustainable alternatives for cooling applications, particularly when integrated with renewable energy sources such as solar thermal systems. Among the available working pairs, the NH₃–NaSCN solution offers favorable thermodynamic properties and low environmental impact; however, its performance under tropical climatic conditions with solar integration remains insufficiently explored. This study evaluates the thermodynamic and exergetic performance of a single-effect NH₃–NaSCN absorption refrigeration cycle integrated with a flat-plate solar collector, considering the climatic conditions of five cities of the Colombian Caribbean Region. A validated thermodynamic model was applied to assess the influence of generator, condenser, absorber, and evaporator temperatures on the coefficient of performance (COP) and exergetic efficiency. Results show that increasing generator temperature from 75 °C to 120 °C enhances COP by up to 46.15 %, while raising the evaporator temperature from –8 °C to 4 °C improves COP by 16 %. Conversely, increasing condenser and absorber temperatures reduce COP by 20.54 % and 16 %, respectively. Exergy destruction analysis indicates that the generator and absorber account for 55 % and 34 % of total irreversibilities, highlighting them as priority targets for optimization. Analysis of variance identified generator temperature as the most influential parameter on COP (39.37 %), followed by condenser (31.22 %) and evaporator temperatures (15.18 %). Solar integration enabled stable operation with an average COP decrease of only 3 % across the five cities; however, the use of water in the solar collector restricted operation below the optimal efficiency range (95–120 °C). The combined performance index integrating COP and exergetic efficiency showed that the operating range characterized by elevated generator temperature and reduced condenser temperature delivers the best energy–exergy trade-off, providing design guidelines for high-irradiance regions and supporting the adoption of NH₃–NaSCN as a cost-effective, renewable refrigeration solution.</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2026-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/61668</dc:identifier>
	<dc:identifier>10.61435/ijred.2026.61668</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 15, No 2 (2026): March 2026; 358-371</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/61668/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 The Author(s). Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>