Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

CFD analysis of photovoltaic panel performance under variable weather conditions with natural and forced convective cooling

International Journal of Renewable Energy Development : JRED · Vol. 15 No. 4 (2026) · hlm. 808–817

DOI
10.61435/ijred.2026.62339
ISSN
2252-4940
Terbit
2026-07-01
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The objective of this study is to numerically investigate the influence of climatic conditions, particularly ambient temperature and relative humidity, on the thermal and electrical performance of photovoltaic (PV) panels, and to evaluate the effectiveness of natural and forced convection cooling for both conventional and finned panel configurations. A multilevel computational fluid dynamics (CFD) model was developed using ANSYS Fluent 16.1 under realistic environmental conditions of Baghdad, Iraq. Two configurations were examined: a conventional flat panel and a modified panel equipped with longitudinal fins acting as a passive heat sink. Under both natural and forced convection, with an inlet air velocity of 1.5 m/s for forced cooling, the simulations took into account solar radiation, species transport to capture humidity effects, and the k–ω turbulence model. Under natural convection, the traditional panel attained a maximum surface temperature of 333.11 K with an electrical efficiency of 27.8%; forced convection lowered the temperature to 319.22 K and increased efficiency to 29.88% (7.5% improvement). Under natural cooling, the finned design lowered the temperature to 327.4 K, raising the efficiency to 28.66% (~3% increase). Under forced cooling, it further dropped to 315.5 K, reaching a maximum efficiency of 30.43%. This translates to advancements of 9.4% over the traditional natural cooling scenario and 6.17% over the finned natural cooling scenario. Yearly average results show that the finned design improves electrical efficiency by about 2% under natural convection and up to 6.53% under forced convection, whereas forced cooling of the conventional panel gives a 3.12% increase. The enhancement is primarily attributed to increased heat transfer surface area and improved convective mixing, particularly under natural convection where fin-induced vortices significantly enhance heat dissipation.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 15 tautan kepenulisan bersama · 8 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Northern Technical University
  • University of Kirkuk
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">CFD analysis of photovoltaic panel performance under variable weather conditions with natural and forced convective cooling</dc:title>
	<dc:creator>Abduljabbar, Ayaz Aydin</dc:creator>
	<dc:creator>Mohammed, Manar</dc:creator>
	<dc:creator>Ali, Zahraa H. Mohammed</dc:creator>
	<dc:creator>Ali, Hussein Hayder Mohammed</dc:creator>
	<dc:creator>Ali, Furqan Haider Mohammed</dc:creator>
	<dc:creator>Khidir, Timur Choban</dc:creator>
	<dc:subject xml:lang="en-US">Solar energy; Photovoltaic; fins; computational fluid dynamics; Thermodynamic analysis; finite volume method</dc:subject>
	<dc:description xml:lang="en-US">The objective of this study is to numerically investigate the influence of climatic conditions, particularly ambient temperature and relative humidity, on the thermal and electrical performance of photovoltaic (PV) panels, and to evaluate the effectiveness of natural and forced convection cooling for both conventional and finned panel configurations. A multilevel computational fluid dynamics (CFD) model was developed using ANSYS Fluent 16.1 under realistic environmental conditions of Baghdad, Iraq. Two configurations were examined: a conventional flat panel and a modified panel equipped with longitudinal fins acting as a passive heat sink. Under both natural and forced convection, with an inlet air velocity of 1.5 m/s for forced cooling, the simulations took into account solar radiation, species transport to capture humidity effects, and the k–ω turbulence model. Under natural convection, the traditional panel attained a maximum surface temperature of 333.11 K with an electrical efficiency of 27.8%; forced convection lowered the temperature to 319.22 K and increased efficiency to 29.88% (7.5% improvement). Under natural cooling, the finned design lowered the temperature to 327.4 K, raising the efficiency to 28.66% (~3% increase). Under forced cooling, it further dropped to 315.5 K, reaching a maximum efficiency of 30.43%. This translates to advancements of 9.4% over the traditional natural cooling scenario and 6.17% over the finned natural cooling scenario. Yearly average results show that the finned design improves electrical efficiency by about 2% under natural convection and up to 6.53% under forced convection, whereas forced cooling of the conventional panel gives a 3.12% increase. The enhancement is primarily attributed to increased heat transfer surface area and improved convective mixing, particularly under natural convection where fin-induced vortices significantly enhance heat dissipation.</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2026-07-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/62339</dc:identifier>
	<dc:identifier>10.61435/ijred.2026.62339</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 15, No 4 (2026): July 2026; 808-817</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/62339/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 The Author(s). Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>