Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

A systematic decision-making approach to optimizing microgrid energy sources in rural areas through diesel generator operation and techno-economic analysis: A case study of Baron Technopark in Indonesia

International Journal of Renewable Energy Development : JRED · Vol. 13 No. 2 (2024) · hlm. 315–328

DOI
10.61435/ijred.2024.59560
ISSN
2252-4940
Terbit
2024-03-01
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Microgrid systems are part of the most reliable energy supply technologies for rural communities that do not have access to electricity but the system is generally dominated by diesel generators (DG). The implementation of de-dieselization programs to ensure efficient diesel operations requires addressing several scenarios such as the replacement of diesel completely with 100% renewable energy sources at a significant cost. The design and selection of appropriate configuration, as well as operating patterns, need to be considered in adopting economical and reliable microgrid systems. Therefore, this study aimed to design an optimal configuration and operational pattern for microgrid systems for the frontier, outermost, and least developed (3T) regions using Baron Techno Park (BTP) in Indonesia as a case study. The optimization was conducted through HOMER software combined with benefit-cost analysis and the focus was on daily load variations, selection of control algorithms, reconfiguration of the power supply system, and setting of the diesel generator operating hours. The results showed that the optimum configuration was achieved using loads of resort, 24 kWp of PV, 288 kWh of BESS, load-following (LF) as dispatch controller, and 25 kVa of DG. Moreover, the proposed microgrid system produced 12% excess energy, 36% renewable fraction (RF), 13.25 tons reduction in CO2 emissions per year, $0.28 LCOE per kWh, $250,478 NPC, and a benefit-cost ratio (BCR) of 0.89. It also had a potential energy efficiency savings of 55.56% and a cost efficiency of 20.95% compared to existing system configurations. In conclusion, the study showed that the addition of DG to microgrid systems in 3T areas was more optimal than using only PV and batteries. An effective operating schedule for the DG was also necessary to improve RF and reduce expenses. Furthermore, other energy storage devices considered less expensive than batteries could be introduced to improve the economics of microgrid systems in the 3T region.

Kata kunci

Jaringan kolaborasi para penulis

31 penulis · 169 tautan kepenulisan bersama · 20 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • National Research and Innovation Agency
  • University of Indonesia
  • Badan Pengkajian dan Penerapan Teknologi
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Rachmawan Atmaji PerdanaBadan Pengkajian dan Penerapan Teknologi1
Muhammad Nurkhoiri HindratnoNational Research and Innovation Agency1
Tanzi Mubaroq SantosoNational Research and Innovation Agency1
Topan Try HarmandaNational Research and Innovation Agency1
Friyogi Resvy MahdaNational Research and Innovation Agency1
Yahya Andreas LapianNational Research and Innovation Agency1
Monica Dwi W. S.National Research and Innovation Agency1
Dionysius Aldion RenataNational Research and Innovation Agency1
Meidy LayooariNational Research and Innovation Agency1
Kusnanda SupriatnaNational Research and Innovation Agency1
Rully KusumajayaNational Research and Innovation Agency1
Mohammad HamdaniNational Research and Innovation Agency1
Amiral AzizNational Research and Innovation Agency1
Didik RostyonoNational Research and Innovation Agency1
Toha ZakyNational Research and Innovation Agency1
Nurry Widya HestyNational Research and Innovation Agency1
Khotimatul FauziahNational Research and Innovation Agency1
Ridwan Budi PrasetyoNational Research and Innovation Agency1
Rudi Purwo WijayantoNational Research and Innovation Agency1
Ario WitjaksoNational Research and Innovation Agency1
Taurista Perdana SyawitriNational Research and Innovation Agency1
Agustina Putri MayasariNational Research and Innovation Agency1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">A systematic decision-making approach to optimizing microgrid energy sources in rural areas through diesel generator operation and techno-economic analysis: A case study of Baron Technopark in Indonesia</dc:title>
	<dc:creator>Prawitasari, Adinda</dc:creator>
	<dc:creator>Nurliyanti, Vetri</dc:creator>
	<dc:creator>Putri Utami, Dannya Maharani</dc:creator>
	<dc:creator>Nurdiana, Eka</dc:creator>
	<dc:creator>Akhmad, Kholid</dc:creator>
	<dc:creator>Aji, Prasetyo</dc:creator>
	<dc:creator>Syafei, Suhraeni</dc:creator>
	<dc:creator>Ifanda, Ifanda</dc:creator>
	<dc:creator>Mulyana, Iwa Garniwa</dc:creator>
	<dc:subject xml:lang="en-US">benefit-cost ratio; cost efficiency; diesel generator operation; excess energy; microgrid optimization; renewable fraction</dc:subject>
	<dc:description xml:lang="en-US">Microgrid systems are part of the most reliable energy supply technologies for rural communities that do not have access to electricity but the system is generally dominated by diesel generators (DG). The implementation of de-dieselization programs to ensure efficient diesel operations requires addressing several scenarios such as the replacement of diesel completely with 100% renewable energy sources at a significant cost. The design and selection of appropriate configuration, as well as operating patterns, need to be considered in adopting economical and reliable microgrid systems. Therefore, this study aimed to design an optimal configuration and operational pattern for microgrid systems for the frontier, outermost, and least developed (3T) regions using Baron Techno Park (BTP) in Indonesia as a case study. The optimization was conducted through HOMER software combined with benefit-cost analysis and the focus was on daily load variations, selection of control algorithms, reconfiguration of the power supply system, and setting of the diesel generator operating hours. The results showed that the optimum configuration was achieved using loads of resort, 24 kWp of PV, 288 kWh of BESS, load-following (LF) as dispatch controller, and 25 kVa of DG. Moreover, the proposed microgrid system produced 12% excess energy, 36% renewable fraction (RF), 13.25 tons reduction in CO2 emissions per year, $0.28 LCOE per kWh, $250,478 NPC, and a benefit-cost ratio (BCR) of 0.89. It also had a potential energy efficiency savings of 55.56% and a cost efficiency of 20.95% compared to existing system configurations. In conclusion, the study showed that the addition of DG to microgrid systems in 3T areas was more optimal than using only PV and batteries. An effective operating schedule for the DG was also necessary to improve RF and reduce expenses. Furthermore, other energy storage devices considered less expensive than batteries could be introduced to improve the economics of microgrid systems in the 3T region.</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2024-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/59560</dc:identifier>
	<dc:identifier>10.61435/ijred.2024.59560</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 13, No 2 (2024): March 2024; 315-328</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/59560/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 The Author(s). Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>