Effect of generator temperature on steam ejector performance in renewable refrigeration cycle considering wet steam model and dry steam model

International Journal of Renewable Energy Development : JRED · Vol. 13 No. 3 (2024) · hlm. 386–395

DOI
10.61435/ijred.2024.59394
ISSN
2252-4940
Terbit
2024-05-01
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The rise in global warming has led to an increased utilization of cooling systems. High energy consumption associated with common refrigeration cycles not only contributes to air pollution but also intensifies the consumption of fossil fuels. Consequently, the imperative to conserve energy has become paramount in today's world. One of the methods to decrease energy consumption involves employing systems capable of harnessing waste heat from industries, solar energy, and other sources. The ejector refrigeration cycle (ERC) stands as an example of such systems. In present study, the impact of elevating the generator temperature on various aspects such as flow behavior in the ejector, aerodynamic shocks, entrainment ratio (ER), and entropy production was examined. The investigation encompassed both wet steam model (WSM) and dry steam model (DSM). Based on the findings, it was observed that with an increase in generator temperature, the ER decreases while the production entropy increases. In the WSM, the liquid mass fraction (LMF) also experiences an increase. Additionally, the Mach number distribution in the DSM surpasses that of the WSM and the temperature drop in the DSM is greater compared to the WSM. With the rise in generator temperature from 388 K to 418 K, both the DSM and WSM exhibit a decrease in ER by 52.9% and 58.7%, respectively. Furthermore, the production entropy experiences a substantial increase of 180% and 206% for the DSM and WSM, respectively.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Guangxi Technological College of Machinery and Electricity
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Effect of generator temperature on steam ejector performance in renewable refrigeration cycle considering wet steam model and dry steam model</dc:title>
	<dc:creator>Jiang, Jian</dc:creator>
	<dc:creator>Yin, Yanping</dc:creator>
	<dc:subject xml:lang="en-US">Ejector refrigeration cycle; Steam Ejector; Generator temperature; Entrainment ratio; Entropy generation</dc:subject>
	<dc:description xml:lang="en-US">The rise in global warming has led to an increased utilization of cooling systems. High energy consumption associated with common refrigeration cycles not only contributes to air pollution but also intensifies the consumption of fossil fuels. Consequently, the imperative to conserve energy has become paramount in today's world. One of the methods to decrease energy consumption involves employing systems capable of harnessing waste heat from industries, solar energy, and other sources. The ejector refrigeration cycle (ERC) stands as an example of such systems. In present study, the impact of elevating the generator temperature on various aspects such as flow behavior in the ejector, aerodynamic shocks, entrainment ratio (ER), and entropy production was examined. The investigation encompassed both wet steam model (WSM) and dry steam model (DSM). Based on the findings, it was observed that with an increase in generator temperature, the ER decreases while the production entropy increases. In the WSM, the liquid mass fraction (LMF) also experiences an increase. Additionally, the Mach number distribution in the DSM surpasses that of the WSM and the temperature drop in the DSM is greater compared to the WSM. With the rise in generator temperature from 388 K to 418 K, both the DSM and WSM exhibit a decrease in ER by 52.9% and 58.7%, respectively. Furthermore, the production entropy experiences a substantial increase of 180% and 206% for the DSM and WSM, respectively.</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2024-05-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/59394</dc:identifier>
	<dc:identifier>10.61435/ijred.2024.59394</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 13, No 3 (2024): May 2024; 386-395</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/59394/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 The Author(s). Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>