The application of equilibrium optimizer for solving modern economic load dispatch problem considering renewable energies and multiple-fuel thermal units

International Journal of Renewable Energy Development : JRED · Vol. 12 No. 3 (2023) · hlm. 590–600

DOI
10.14710/ijred.2023.52835
ISSN
2252-4940
Terbit
2023-05-15
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This study presents a modern version of the economic load dispatch (MELD) problem with the contribution of renewable energies and conventional energy, including wind, solar and thermal power plants. In the study, reduction of electricity generation cost is the first priority, while the use of multiple fuels in the thermal power plant is considered in addition to the consideration of all constraints of power plants. Two meta-heuristic algorithms, one conventional and one recently published, including Particle swarm optimization (PSO) and Equilibrium optimizer (EO), are applied to determine the optimal solutions for MELD. A power system with ten thermal power plants using multiple fossil fuels, one wind power plant, and three solar power plants is utilized to evaluate the performance of both PSO and EO. Unlike other previous studies, this paper considers the MELD problem with the change of load demands over one day with 24 periods as a real power system. In addition, the power generated by both wind and solar power plants varies at each period. The results obtained by applying the two algorithms indicate that EO is completely superior to PSO, and the solutions found by EO can satisfy all constraints. Particularly in Case 1 with different load demand values, EO achieves better total electricity production cost (TEGC) than PSO by 0.75%, 0.87%, 0.13%, and 0.45% for the loads of 2400 MW, 2500 MW, 2600 MW and 2700 MW. Moreover, EO also provides a faster response capability over PSO through the four subcases although EO and PSO are run by the same selection of control parameters. In Case 2, the high efficiency provided by EO is still maintained, though the scale of the considered problem has been substantially enlarged. Specifically, EO can save $51.2 compared to PSO for the minimum TEGC. The savings cost is equal to 0.33% for the whole schedule of 24 hours. With these results, EO is acknowledged as a favourable search method for dealing with the MELD problem. Besides, this study also points out the difference in performance between a modern meta-heuristic algorithm (EO) and the classical one (PSO). The modern metaheuristic algorithm with special structure is highly valuable for complicated problem as MELD.

Kata kunci

Jaringan kolaborasi para penulis

15 penulis · 30 tautan kepenulisan bersama · 16 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Ho Chi Minh City University of Technology
  • Ton Duc Thang University
  • University of Theatre and Cinema Ho Chi Minh City
  • Van Lang University
  • Ho Chi Minh City University of Technology and Engineering
  • Saigon University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Thang Trung NguyenTon Duc Thang University4
Ly Huu PhamTon Duc Thang University3
Bach Hoang DinhTon Duc Thang University2
Van-Duc PhanVan Lang University2
Phan Nguyen VinhUniversity of Theatre and Cinema Ho Chi Minh City2
Thai Dinh PhamHo Chi Minh City University of Technology and Engineering1
Chi Trung TruongAfiliasi tidak diketahui1
Quoc Trung NguyenAfiliasi tidak diketahui1
Minh‐Duc PhamHo Chi Minh City University of Technology1
Hong Phuc LamHo Chi Minh City University of Technology1
Phu Trieu HaSaigon University1
Tran Trong DaoTon Duc Thang University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">The application of equilibrium optimizer for solving modern economic load dispatch problem considering renewable energies and multiple-fuel thermal units</dc:title>
	<dc:creator>Nguyen, Hung Duc</dc:creator>
	<dc:creator>Truong, Khoa Hoang</dc:creator>
	<dc:creator>Le, Nhuan An</dc:creator>
	<dc:subject xml:lang="en-US">Economic load dispatch; Particle swarm optimization; Equilibrium optimizer; multiple fuels; thermal generator; renewable energies.</dc:subject>
	<dc:description xml:lang="en-US">This study presents a modern version of the economic load dispatch (MELD) problem with the contribution of renewable energies and conventional energy, including wind, solar and thermal power plants. In the study, reduction of electricity generation cost is the first priority, while the use of multiple fuels in the thermal power plant is considered in addition to the consideration of all constraints of power plants. Two meta-heuristic algorithms, one conventional and one recently published, including Particle swarm optimization (PSO) and Equilibrium optimizer (EO), are applied to determine the optimal solutions for MELD. A power system with ten thermal power plants using multiple fossil fuels, one wind power plant, and three solar power plants is utilized to evaluate the performance of both PSO and EO. Unlike other previous studies, this paper considers the MELD problem with the change of load demands over one day with 24 periods as a real power system. In addition, the power generated by both wind and solar power plants varies at each period. The results obtained by applying the two algorithms indicate that EO is completely superior to PSO, and the solutions found by EO can satisfy all constraints. Particularly in Case 1 with different load demand values, EO achieves better total electricity production cost (TEGC) than PSO by 0.75%, 0.87%, 0.13%, and 0.45% for the loads of 2400 MW, 2500 MW, 2600 MW and 2700 MW. Moreover, EO also provides a faster response capability over PSO through the four subcases although EO and PSO are run by the same selection of control parameters. In Case 2, the high efficiency provided by EO is still maintained, though the scale of the considered problem has been substantially enlarged. Specifically, EO can save $51.2 compared to PSO for the minimum TEGC. The savings cost is equal to 0.33% for the whole schedule of 24 hours. With these results, EO is acknowledged as a favourable search method for dealing with the MELD problem. Besides, this study also points out the difference in performance between a modern meta-heuristic algorithm (EO) and the classical one (PSO). The modern metaheuristic algorithm with special structure is highly valuable for complicated problem as MELD.</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2023-05-15</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/52835</dc:identifier>
	<dc:identifier>10.14710/ijred.2023.52835</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 12, No 3 (2023): May 2023; 590-600</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/52835/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 The Author(s). Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>