Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

A four-line active shunt filter to enhance the power quality in a microgrid

International Journal of Renewable Energy Development : JRED · Vol. 12 No. 3 (2023) · hlm. 488–498

DOI
10.14710/ijred.2023.50270
ISSN
2252-4940
Terbit
2023-05-15
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

In recent years, power quality has become a major concern for electric network managers. Active filtering control schemes ensure improved power quality of the electric network and are able to maintain a desired voltage level at the point of connection, regardless of the current absorbed by nonlinear loads. Harmonics can cause vibrations, equipment distortion, losses and sweatiness in transformers. The main objective of this work is to enhance the quality of energy in a microgrid consisting of 100 kW photovoltaic (PV) system and a 50 kW battery storage connected to nonlinear and unbalanced loads. This paper proposes a the four-arm parallel active filter with a on Proportional-Integral (PI) controller to mitigate the harmonic problems in a microgrid. In addition, an algorithm has been designed to eliminate the neutral current. The identification function is one of the most particular approach for extracting harmonics, it involves providing a current reference imposed by the active filter in order to carry out the filtering operation. Both the performance and the quality of the current harmonic compensation's depend strongly on the strategy adopted for the generating the current reference. In this work, the instantaneous power strategy p-q is chosen outstanding the simplicity and effectiveness in implementation. The proposed control strategy has been tested under simulations and the results have shown good tracking of the references and a significant reduction in the Total Harmonic Distorsion (THD) level under highly unbalanced conditions of the nonlinear loads. The current THD is reduced from 43.64 before filtering to 3.74% after the application of the four-arm filter, following the recommendations of IEEE-519 standard (THD less than 5%).

Kata kunci

Jaringan kolaborasi para penulis

26 penulis · 68 tautan kepenulisan bersama · 19 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Ahmed Zabana University - Relizane
  • Université des Sciences et de la Technologie d'Oran Mohamed Boudiaf
  • University of Bechar
  • University of Hertfordshire
  • University of Oran 2 Mohamed Ben Ahmed
  • École Nationale Polytechnique d'Oran
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mouloud Azzedine DenaiUniversity of Hertfordshire4
Othmane AbdelkhalekUniversity of Bechar3
Abdallah Ben AbdelkaderUniversity of Bechar3
Toufik ToumiUniversity of Bechar3
Abdelmalek MeftouhiUniversity of Bechar3
M. KhodjaAhmed Zabana University - Relizane3
Hamid BouzeboudjaUniversité des Sciences et de la Technologie d'Oran Mohamed Boudiaf3
Yacine HociniAfiliasi tidak diketahui2
Mahmoud Mostefa TounsiAhmed Zabana University - Relizane2
Azeddine BendiabdellahUniversité des Sciences et de la Technologie d'Oran Mohamed Boudiaf2
Benamar Tahar KarimUniversité des Sciences et de la Technologie d'Oran Mohamed Boudiaf2
Belkacem BelkacemUniversity of Oran 2 Mohamed Ben Ahmed1
Noureddine BouhamriUniversity of Oran 2 Mohamed Ben Ahmed1
Lahouari Abdelhakem-KoridakAfiliasi tidak diketahui1
Noureddine BenabadjiUniversité des Sciences et de la Technologie d'Oran Mohamed Boudiaf1
Falil FatimaUniversité des Sciences et de la Technologie d'Oran Mohamed Boudiaf1
Allali AhmedAfiliasi tidak diketahui1
Boumerid Bensahila Med El AmineUniversité des Sciences et de la Technologie d'Oran Mohamed Boudiaf1
Denai MouloudUniversity of Hertfordshire1
Mohammed Amine SoumeurUniversity of Bechar1
Bouhenna AminaAhmed Zabana University - Relizane1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">A four-line active shunt filter to enhance the power quality in a microgrid</dc:title>
	<dc:creator>Mostefa, Abdelkader</dc:creator>
	<dc:creator>Belalia, Karim</dc:creator>
	<dc:creator>Lantri, Tayeb</dc:creator>
	<dc:creator>Boulouiha, Houari Merabet</dc:creator>
	<dc:creator>Allali, Ahmed</dc:creator>
	<dc:subject xml:lang="en-US">Harmonic pollution; non-linear load; active parallel filter; neutrality fault; the pq method; quadruple-wire inverter</dc:subject>
	<dc:description xml:lang="en-US">In recent years, power quality has become a major concern for electric network managers. Active filtering control schemes ensure improved power quality of the electric network and are able to maintain a desired voltage level at the point of connection, regardless of the current absorbed by nonlinear loads. Harmonics can cause vibrations, equipment distortion, losses and sweatiness in transformers. The main objective of this work is to enhance the quality of energy in a microgrid consisting of 100 kW photovoltaic (PV) system and a 50 kW battery storage connected to nonlinear and unbalanced loads. This paper proposes a the four-arm parallel active filter with a on Proportional-Integral (PI) controller to mitigate the harmonic problems in a microgrid. In addition, an algorithm has been designed to eliminate the neutral current. The identification function is one of the most particular approach for extracting harmonics, it involves providing a current reference imposed by the active filter in order to carry out the filtering operation. Both the performance and the quality of the current harmonic compensation's depend strongly on the strategy adopted for the generating the current reference. In this work, the instantaneous power strategy p-q is chosen outstanding the simplicity and effectiveness in implementation. The proposed control strategy has been tested under simulations and the results have shown good tracking of the references and a significant reduction in the Total Harmonic Distorsion (THD) level under highly unbalanced conditions of the nonlinear loads. The current THD is reduced from 43.64 before filtering to 3.74% after the application of the four-arm filter, following the recommendations of IEEE-519 standard (THD less than 5%).</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2023-05-15</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/50270</dc:identifier>
	<dc:identifier>10.14710/ijred.2023.50270</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 12, No 3 (2023): May 2023; 488-498</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/50270/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 The Author(s). Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>