Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

AI-optimization operation of biomass-based distributed generator for efficient radial distribution system

International Journal of Renewable Energy Development : JRED · Vol. 13 No. 6 (2024) · hlm. 1044–1057

DOI
10.61435/ijred.2024.60224
ISSN
2252-4940
Terbit
2024-11-01
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This research aims to optimize the size and location of biomass-based distributed generator (BMDG) units to enhance the voltage profile, reduce electrical losses, maximize cost savings, and decrease emissions from power distribution systems. Biomass-based distributed generator (BMDG) systems offer numerous advantages to enhance the efficiency of power distribution systems. However, achieving these benefits relies on determining the optimal size and position of the BMDGs. To achieve these objectives, the metaheuristic technique called particle swarm optimization (PSO) is employed to find the optimal placement and size of BMDGs. The proposed model was validated on MATLAB's IEEE-33 bus radial distribution system (RDS), confirming the aforementioned benefits. Comparative analysis between the PSO-based technique and other algorithms from previous research revealed better results with the proposed method. The results indicate that optimal placement and sizing of BMDG units have led to a reduction of more than 67.68% in active power losses and 65.90% in reactive power losses compared to the base case. Additionally, the reduction in active power loss was 40.44%, 11.39%, 42.85%, 1.81%, 0.85%, 29.83%, 5.82% and 28.38% more than artificial bee colony, backtracking search optimization algorithm, moth-flame optimization, Coordinate control, artificial Hummingbird algorithm, variable constants PSO (VCPSO), artificial gorilla troops optimizer (AGTO), and a jellyfish search optimizer respectively. Furthermore, the reactive power losses were reduced by 38.33% and 15.68% compared to VCPSO and AGTO respectively. Furthermore, this study revealed a cost reduction of 6.38% when compared to the AGTO and 1.30% when compared to the AHA. Moreover, the voltage profile of the power distribution system was improved by 7.28%. The presented methodology has demonstrated promising results for BMDGs in RDS across various applications.

Kata kunci

Jaringan kolaborasi para penulis

13 penulis · 31 tautan kepenulisan bersama · 19 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Government College University, Faisalabad
  • University of Technology Malaysia
  • University of Engineering and Technology Lahore
  • Ministry of Water Resources of the People's Republic of China
  • University of Botswana
  • University of Engineering and Technology Taxila
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mohd Junaidi Abdul AzizUniversity of Technology Malaysia1
Zainal SalamUniversity of Technology Malaysia1
Kong Pui YeeUniversity of Technology Malaysia1
Lin NingMinistry of Water Resources of the People's Republic of China1
Waqas AliUniversity of Engineering and Technology Lahore1
Haroon FarooqUniversity of Engineering and Technology Lahore1
Intisar Ali SajjadUniversity of Engineering and Technology Taxila1
Cui ZhenhuaMinistry of Water Resources of the People's Republic of China1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">AI-optimization operation of biomass-based distributed generator for efficient radial distribution system</dc:title>
	<dc:creator>Ali, Muhammad Abid</dc:creator>
	<dc:creator>Bhatti, Abdul Rauf</dc:creator>
	<dc:creator>Farhan, Muhammad</dc:creator>
	<dc:creator>Rasool, Akhtar</dc:creator>
	<dc:creator>Ali, Ahmed</dc:creator>
	<dc:subject xml:lang="en-US">Biomass-based distributed generator (BMDG); particle swarm optimization (PSO); optimal placement and sizing; IEEE-33; radial distribution system (RDS)</dc:subject>
	<dc:description xml:lang="en-US">This research aims to optimize the size and location of biomass-based distributed generator (BMDG) units to enhance the voltage profile, reduce electrical losses, maximize cost savings, and decrease emissions from power distribution systems. Biomass-based distributed generator (BMDG) systems offer numerous advantages to enhance the efficiency of power distribution systems. However, achieving these benefits relies on determining the optimal size and position of the BMDGs. To achieve these objectives, the metaheuristic technique called particle swarm optimization (PSO) is employed to find the optimal placement and size of BMDGs. The proposed model was validated on MATLAB's IEEE-33 bus radial distribution system (RDS), confirming the aforementioned benefits. Comparative analysis between the PSO-based technique and other algorithms from previous research revealed better results with the proposed method. The results indicate that optimal placement and sizing of BMDG units have led to a reduction of more than 67.68% in active power losses and 65.90% in reactive power losses compared to the base case. Additionally, the reduction in active power loss was 40.44%, 11.39%, 42.85%, 1.81%, 0.85%, 29.83%, 5.82% and 28.38% more than artificial bee colony, backtracking search optimization algorithm, moth-flame optimization, Coordinate control, artificial Hummingbird algorithm, variable constants PSO (VCPSO), artificial gorilla troops optimizer (AGTO), and a jellyfish search optimizer respectively. Furthermore, the reactive power losses were reduced by 38.33% and 15.68% compared to VCPSO and AGTO respectively. Furthermore, this study revealed a cost reduction of 6.38% when compared to the AGTO and 1.30% when compared to the AHA. Moreover, the voltage profile of the power distribution system was improved by 7.28%. The presented methodology has demonstrated promising results for BMDGs in RDS across various applications.</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2024-11-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/60224</dc:identifier>
	<dc:identifier>10.61435/ijred.2024.60224</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 13, No 6 (2024): November 2024; 1044-1057</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/60224/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 The Author(s). Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>