Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Robust control strategy for optimized IM-4S-VSI-based wind turbine simulator: Assessment for theoretical study

International Journal of Renewable Energy Development : JRED · Vol. 15 No. 3 (2026) · hlm. 543–558

DOI
10.61435/ijred.2026.61842
ISSN
2252-4940
Terbit
2026-05-01
Penerbit
Center of Biomass & Renewable Energy (CBIORE)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Wind turbine emulation faces significant challenges in achieving high dynamic performance while maintaining low-cost and sensorless control architectures suitable for laboratory validation. This paper proposes a software-based wind turbine simulator replicating the dynamic behavior of a 3 kW wind turbine under realistic wind conditions, including quasi-stationary, stochastic, and localized gust (Mexican Hat) profiles. The emulator is implemented using a three-phase induction motor driven by a four-switch voltage source inverter (4S-VSI), controlled via rotor field-oriented control and space vector modulation. A sliding-mode observer (SMO) is employed to estimate rotor speed and flux from stator current measurements, eliminating mechanical sensors. Additionally, an adaptive parameter estimator based on the reactive power method is incorporated into the control loop to identify the rotor resistance in real time. Under nominal loaded operation, the proposed scheme achieves speed tracking errors below 1%, torque errors below 6%, and rotor flux errors below 2% across all wind profiles. When a severe +100% rotor resistance variation is introduced, speed deviation reaches 10% and torque error approaches 20% prior to adaptation, while estimated quantities remain stable, demonstrating observer robustness. Once the reactive power–based adaptation is activated, speed error returns to nearly zero, torque error falls below 5%, stator current error remains under 3%, and flux deviation becomes negligible. The maximum observed speed overshoot under gust excitation is 13.27%, with a settling time of 0.31 s. A quantitative comparison with a conventional six-switch VSI shows that the proposed 4S-VSI reduces switching activity by approximately 43% (from 44.89 kHz to 25.72 kHz equivalent switching frequency), leading to lower switching losses and reduced hardware complexity without compromising dynamic performance. These results demonstrate that the proposed architecture achieves robust observer convergence, accurate wind profile emulation, and significant converter loss reduction, providing a cost-effective and computationally efficient platform for real-time validation of wind energy conversion systems.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 5 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Sousse
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Akram AmriUniversity of Sousse2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Robust control strategy for optimized IM-4S-VSI-based wind turbine simulator: Assessment for theoretical study</dc:title>
	<dc:creator>Zerzeri, Mouna</dc:creator>
	<dc:creator>Moussa, Intissar</dc:creator>
	<dc:creator>Khedher, Adel</dc:creator>
	<dc:subject xml:lang="en-US">Wind turbine emulator; Induction motor; 4S-VSI; Sliding mode observer; sensorless control; Reactive power estimation; Parameter adaptation</dc:subject>
	<dc:description xml:lang="en-US">Wind turbine emulation faces significant challenges in achieving high dynamic performance while maintaining low-cost and sensorless control architectures suitable for laboratory validation. This paper proposes a software-based wind turbine simulator replicating the dynamic behavior of a 3 kW wind turbine under realistic wind conditions, including quasi-stationary, stochastic, and localized gust (Mexican Hat) profiles. The emulator is implemented using a three-phase induction motor driven by a four-switch voltage source inverter (4S-VSI), controlled via rotor field-oriented control and space vector modulation. A sliding-mode observer (SMO) is employed to estimate rotor speed and flux from stator current measurements, eliminating mechanical sensors. Additionally, an adaptive parameter estimator based on the reactive power method is incorporated into the control loop to identify the rotor resistance in real time. Under nominal loaded operation, the proposed scheme achieves speed tracking errors below 1%, torque errors below 6%, and rotor flux errors below 2% across all wind profiles. When a severe +100% rotor resistance variation is introduced, speed deviation reaches 10% and torque error approaches 20% prior to adaptation, while estimated quantities remain stable, demonstrating observer robustness. Once the reactive power–based adaptation is activated, speed error returns to nearly zero, torque error falls below 5%, stator current error remains under 3%, and flux deviation becomes negligible. The maximum observed speed overshoot under gust excitation is 13.27%, with a settling time of 0.31 s. A quantitative comparison with a conventional six-switch VSI shows that the proposed 4S-VSI reduces switching activity by approximately 43% (from 44.89 kHz to 25.72 kHz equivalent switching frequency), leading to lower switching losses and reduced hardware complexity without compromising dynamic performance. These results demonstrate that the proposed architecture achieves robust observer convergence, accurate wind profile emulation, and significant converter loss reduction, providing a cost-effective and computationally efficient platform for real-time validation of wind energy conversion systems.</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2026-05-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/61842</dc:identifier>
	<dc:identifier>10.61435/ijred.2026.61842</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 15, No 3 (2026): May 2026; 543-558</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/61842/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 The Author(s). Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>