Abstrak

Elevated winding insulation temperature, driven by harmonic distortions, is a key factor in transformer lifespan reduction. Conventional models often oversimplify the effect of combined current and voltage harmonics. This paper proposes an electro-thermal modeling approach, incorporating dual heat sources from core and winding domains, to enhance HST estimation in distribution transformers affected by photovoltaic-induced (PV)-induced harmonic losses. A sophisticated numerical approach, Finite Element Analysis (FEA), is employed using COMSOL Multiphysics software, with a 250-minute time-dependent study assessing thermal effects. The results, verified against a mathematical model approach based on IEEE C57.110-2018 guidance, demonstrate that higher levels of harmonics lead to a rapid increase in HST, accelerating the time to reach the aging factor temperature and consequently diminishing the transformer’s operational lifespan. Specifically, the per-unit life of the transformer decreases from 0.219 in Case 1 to 0.154 in Case 2 and 0.027 in Case 3, while the aging acceleration factor increases from 4.310 to 5.683 and 21.7, respectively. The methods showed over 95% alignment with the mathematical modeling approach, confirming the model’s precision in its predictive capability. The novelty of this study lies in its enhanced electro-thermal framework, which overcomes the limitations of conventional methods by integrating dual heat sources and providing a refined assessment of transformer aging under harmonic distortions. This advancement offers a more precise and computationally efficient approach for assessing transformer thermal stress under harmonic distortions.

Kata kunci

Jaringan kolaborasi para penulis

28 penulis · 95 tautan kepenulisan bersama · 49 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Technology Malaysia
  • National Research and Innovation Agency
  • MILA University
  • Tafresh University
  • Beijing Jiaotong University
  • Indonesian Institute of Sciences
  • Bandung Institute of Technology
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Nasarudin AhmadUniversity of Technology Malaysia6
Siti Aisyah Abd WahidUniversity of Technology Malaysia3
Haval Sardar KamilUniversity of Technology Malaysia2
Mohammad Reza MivehTafresh University2
Hayati AbdullahUniversity of Technology Malaysia2
NN Nik Abd MalikUniversity of Technology Malaysia2
Mohd Wazir MustafaUniversity of Technology Malaysia1
Nur Adrinna Shafiqa ZakariaUniversity of Technology Malaysia1
Norzanah RosminUniversity of Technology Malaysia1
Mohamad Shazwan Shah JamilUniversity of Technology Malaysia1
Sohrab MirsaeidiBeijing Jiaotong University1
Md Pauzi AbdullahUniversity of Technology Malaysia1
Mohammad Yusri HassanUniversity of Technology Malaysia1
Faridah HussinUniversity of Technology Malaysia1
Abdul Hafiz RazaliUniversity of Technology Malaysia1
Mohd Wazir MustafaUniversity of Technology Malaysia1
Zulkarnain Ahmad NoordenUniversity of Technology Malaysia1
Ahmad FudholiNational University of Malaysia1
Tinton Dwi AtmajaNational Research and Innovation Agency1
Udin KomarudinUniversitas Widyatama1
Ahmad RajaniIndonesian Institute of Sciences1
Muhammad Subhan ArifinBandung Institute of Technology1
Subagyo SubagyoNational Research and Innovation Agency1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ijred.cbiore.id/index.php/ijred/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">An electro-thermal modeling of distribution transformer for hottest spot evaluation under photovoltaic-induced harmonics</dc:title>
	<dc:creator>Mohd Wazir, Muhammad Haziq</dc:creator>
	<dc:creator>Mat Said, Dalila</dc:creator>
	<dc:creator>Md Sapari, Norazliani</dc:creator>
	<dc:creator>Mohamed Yunus, Mohamed Shahriman</dc:creator>
	<dc:creator>Mohd Yassin, Zaris Izzati</dc:creator>
	<dc:subject xml:lang="en-US">Distribution transformer; harmonics; hotspot temperature; photovoltaic systems; winding insulation</dc:subject>
	<dc:description xml:lang="en-US">Elevated winding insulation temperature, driven by harmonic distortions, is a key factor in transformer lifespan reduction. Conventional models often oversimplify the effect of combined current and voltage harmonics. This paper proposes an electro-thermal modeling approach, incorporating dual heat sources from core and winding domains, to enhance HST estimation in distribution transformers affected by photovoltaic-induced (PV)-induced harmonic losses. A sophisticated numerical approach, Finite Element Analysis (FEA), is employed using COMSOL Multiphysics software, with a 250-minute time-dependent study assessing thermal effects. The results, verified against a mathematical model approach based on IEEE C57.110-2018 guidance, demonstrate that higher levels of harmonics lead to a rapid increase in HST, accelerating the time to reach the aging factor temperature and consequently diminishing the transformer’s operational lifespan. Specifically, the per-unit life of the transformer decreases from 0.219 in Case 1 to 0.154 in Case 2 and 0.027 in Case 3, while the aging acceleration factor increases from 4.310 to 5.683 and 21.7, respectively. The methods showed over 95% alignment with the mathematical modeling approach, confirming the model’s precision in its predictive capability. The novelty of this study lies in its enhanced electro-thermal framework, which overcomes the limitations of conventional methods by integrating dual heat sources and providing a refined assessment of transformer aging under harmonic distortions. This advancement offers a more precise and computationally efficient approach for assessing transformer thermal stress under harmonic distortions.</dc:description>
	<dc:publisher xml:lang="en-US">Center of Biomass &amp; Renewable Energy (CBIORE)</dc:publisher>
	<dc:date>2025-05-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijred.cbiore.id/index.php/ijred/article/view/60959</dc:identifier>
	<dc:identifier>10.61435/ijred.2025.60959</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Renewable Energy Development; Vol 14, No 3 (2025): May 2025; 450-462</dc:source>
	<dc:source>2252-4940</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijred.cbiore.id/index.php/ijred/article/view/60959/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 The Author(s). Published by Centre of Biomass and Renewable Energy (CBIORE)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>