Determining X-Ray Effective Energy in Linear Accelerator (LINAC) Radiotherapy Instrument
JURNAL ILMIAH PENDIDIKAN FISIKA AL BIRUNI · Vol. 7 No. 1 (2018) · hlm. 99–104
ISSN 2503-023X, 2303-1832
Terbit 2018-04-28
Penerbit Universitas Islam Negeri Raden Intan Lampung, Indonesia
Bahasa eng
Abstrak
This research in determining x-ray effective energy in linear accelerator (Linac) radiotherapy device was done using copper plates at different thicknesses by determining the Half Value Layer (HVL) for each energy. The purpose of this research is to know the amount of effective energy used in radiotherapy linear accelerator. The results showed that the energy of 6 MeV obtained 2,714 MeV of effective energy at HVL 4,500 mm and at the energy of 10 MeV obtained 4,231 MeV of effective energy at HVL 4,500 mm.
Jaringan kolaborasi para penulis
11 penulis ·
14 tautan kepenulisan bersama
· 4 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Hasanuddin University University of Mataram Universitas Syiah Kuala National Research and Innovation Agency Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ejournal.radenintan.ac.id/index.php/al-biruni/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en">Determining X-Ray Effective Energy in Linear Accelerator (LINAC) Radiotherapy Instrument</dc:title>
<dc:creator xml:lang="en">Fauziah, Fauziah</dc:creator>
<dc:creator xml:lang="en">Abdullah, Bualkar</dc:creator>
<dc:subject xml:lang="en">copper plates</dc:subject>
<dc:subject xml:lang="en">effective energy</dc:subject>
<dc:subject xml:lang="en">half value layer</dc:subject>
<dc:subject xml:lang="en">linear accelerator</dc:subject>
<dc:description xml:lang="en">This research in determining x-ray effective energy in linear accelerator (Linac) radiotherapy device was done using copper plates at different thicknesses by determining the Half Value Layer (HVL) for each energy. The purpose of this research is to know the amount of effective energy used in radiotherapy linear accelerator. The results showed that the energy of 6 MeV obtained 2,714 MeV of effective energy at HVL 4,500 mm and at the energy of 10 MeV obtained 4,231 MeV of effective energy at HVL 4,500 mm.</dc:description>
<dc:publisher xml:lang="en">Universitas Islam Negeri Raden Intan Lampung, Indonesia</dc:publisher>
<dc:date>2018-04-28</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
<dc:format>application/pdf</dc:format>
<dc:format>application/msword</dc:format>
<dc:identifier>https://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/2336</dc:identifier>
<dc:identifier>10.24042/jipfalbiruni.v7i1.2336</dc:identifier>
<dc:source xml:lang="en">Jurnal Ilmiah Pendidikan Fisika Al-Biruni; Vol. 7 No. 1 (2018): Jurnal Ilmiah Pendidikan Fisika Al-Biruni; 99-104</dc:source>
<dc:source xml:lang="id">Jurnal Ilmiah Pendidikan Fisika Al-Biruni; Vol 7 No 1 (2018): Jurnal Ilmiah Pendidikan Fisika Al-Biruni; 99-104</dc:source>
<dc:source>2503-023X</dc:source>
<dc:source>2303-1832</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/2336/pdf</dc:relation>
<dc:relation>https://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/2336/8256</dc:relation>
<dc:rights xml:lang="en">Copyright (c) 2018 Jurnal Ilmiah Pendidikan Fisika Al-Biruni</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Fauziah, F., & Abdullah, B. (2018). Determining X-Ray Effective Energy in Linear Accelerator (LINAC) Radiotherapy Instrument. JURNAL ILMIAH PENDIDIKAN FISIKA AL BIRUNI, 7(1), 99–104. https://doi.org/10.24042/jipfalbiruni.v7i1.2336
Salin
IEEE
F. Fauziah and B. Abdullah, “Determining X-Ray Effective Energy in Linear Accelerator (LINAC) Radiotherapy Instrument,” JURNAL ILMIAH PENDIDIKAN FISIKA AL BIRUNI, vol. 7, no. 1, pp. 99–104, 2018, doi: 10.24042/jipfalbiruni.v7i1.2336.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.