Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Investigation on electron contamination of LINAC at different operating voltages using particle heavy ion transport code system (PHITS)

JURNAL ILMIAH PENDIDIKAN FISIKA AL BIRUNI · Vol. 11 No. 1 (2022) · hlm. 103–111

DOI
10.24042/jipfalbiruni.v11i1.11929
ISSN
2503-023X, 2303-1832
Terbit
2022-04-30
Penerbit
Universitas Islam Negeri Raden Intan Lampung, Indonesia
Bahasa
eng

Abstrak

Research has been carried out to investigate the occurrence of secondary electron contamination in a linear accelerator (LINAC) machine. The research was conducted in a simulation using a Monte Carlo-based simulator, namely Particle and Heavy Ions Transport code System (PHITS). The simulation of the occurrence of secondary electron contamination was carried out based on the model of the LINAC Electa head that is operated at voltages of 6, 8, 10, 15, 18, and 25 MV, using a field area of 10 X 10 cm and SSD 100 cm. The simulation results show that electron contamination occurs due to the interaction of X-ray photons with the components of the LINAC head, namely the primary collimator, flattening filter, and secondary collimator. The secondary electron contaminants generated by the LINAC head components spread through the water phantom. The higher the operating voltage, the higher the secondary electron flux produced. The secondary electron contamination dose calculated in the water phantom shows that the higher the LINAC voltage, the higher is the dose received in the phantom.

Kata kunci

Jaringan kolaborasi para penulis

38 penulis · 140 tautan kepenulisan bersama · 51 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jenderal Soedirman University
  • State University of Semarang
  • National Nuclear Energy Agency of Indonesia
  • Universitas Gadjah Mada
  • Satya Wacana Christian University
  • Nuclear Science and Technology Research Institute
  • Universitas Islam Negeri Ar-Raniry
  • Organisasi lain
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Dian Riana NingsihJenderal Soedirman University5
Zusfahair ZusfahairJenderal Soedirman University5
Amin FatoniJenderal Soedirman University4
Niken Istikhari MuslihahJenderal Soedirman University3
Bejo HaryantoJenderal Soedirman University2
Masturi MasturiState University of Semarang1
Sunarno SunarnoState University of Semarang1
Rio Agustian Gilang FernandoState University of Semarang1
Pratiwi DwijanantiState University of Semarang1
Hendig WinarnoNational Nuclear Energy Agency of Indonesia1
Bagaswoto PoedjomartonoUniversitas Gadjah Mada1
Edy MeiyantoUniversitas Gadjah Mada1
Desman Perdamaian GuloSatya Wacana Christian University1
T. SuryasatriyaSatya Wacana Christian University1
Slamet Purwo SantosaNational Nuclear Energy Agency of Indonesia1
A. ArifinHasanuddin University1
Jamrud AminuddinJenderal Soedirman University1
Nurhayati NurhayatiUniversitas Islam Negeri Ar-Raniry1
Agustina WidiyaniSumatera Institute of Technology1
Mukhtar EffendiJenderal Soedirman University1
Abdullah Nur AzizJenderal Soedirman University1
Pakhrur RaziUniversitas Negeri Padang1
Wihantoro WihantoroJenderal Soedirman University1
Farzand AbdullatifJenderal Soedirman University1
Sunardi SunardiJenderal Soedirman University1
Aprilia Nafi NurainiJenderal Soedirman University1
Puji LestariJenderal Soedirman University1
Eva AryantiJenderal Soedirman University1
Aris SulistyowatiJenderal Soedirman University1
Ely SetiawanJenderal Soedirman University1
Purwati PurwatiJenderal Soedirman University1
Adilla LuthfiaJenderal Soedirman University1
Inessa Putri ApriliadinaJenderal Soedirman University1
Sifa Nurfadillah SetiawanJenderal Soedirman University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ejournal.radenintan.ac.id/index.php/al-biruni/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Investigation on electron contamination of LINAC at different operating voltages using particle heavy ion transport code system (PHITS)</dc:title>
	<dc:creator xml:lang="en">Bilalodin, Bilalodin</dc:creator>
	<dc:creator xml:lang="en">Haryadi, Aris</dc:creator>
	<dc:creator xml:lang="en">Sardjono, Yohannes</dc:creator>
	<dc:creator xml:lang="en">Kasesaz, Yaser</dc:creator>
	<dc:subject xml:lang="en">LINAC</dc:subject>
	<dc:subject xml:lang="en">Electron contaminant</dc:subject>
	<dc:subject xml:lang="en">Dose</dc:subject>
	<dc:subject xml:lang="en">PHITS Code</dc:subject>
	<dc:description xml:lang="en">Research has been carried out to investigate the occurrence of secondary electron contamination in a linear accelerator (LINAC) machine. The research was conducted in a simulation using a Monte Carlo-based simulator, namely Particle and Heavy Ions Transport code System (PHITS). The simulation of the occurrence of secondary electron contamination was carried out based on the model of the LINAC Electa head that is operated at voltages of 6, 8, 10, 15, 18, and 25 MV, using a field area of 10 X 10 cm and SSD 100 cm. The simulation results show that electron contamination occurs due to the interaction of X-ray photons with the components of the LINAC head, namely the primary collimator, flattening filter, and secondary collimator. The secondary electron contaminants generated by the LINAC head components spread through the water phantom. The higher the operating voltage, the higher the secondary electron flux produced. The secondary electron contamination dose calculated in the water phantom shows that the higher the LINAC voltage, the higher is the dose received in the phantom.</dc:description>
	<dc:publisher xml:lang="en">Universitas Islam Negeri Raden Intan Lampung, Indonesia</dc:publisher>
	<dc:date>2022-04-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/11929</dc:identifier>
	<dc:identifier>10.24042/jipfalbiruni.v11i1.11929</dc:identifier>
	<dc:source xml:lang="en">Jurnal Ilmiah Pendidikan Fisika Al-Biruni; Vol. 11 No. 1 (2022): Jurnal Ilmiah Pendidikan Fisika Al-Biruni; 103-111</dc:source>
	<dc:source xml:lang="id">Jurnal Ilmiah Pendidikan Fisika Al-Biruni; Vol 11 No 1 (2022): Jurnal Ilmiah Pendidikan Fisika Al-Biruni; 103-111</dc:source>
	<dc:source>2503-023X</dc:source>
	<dc:source>2303-1832</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/11929/pdf</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2022 Physics Education Department, UIN Raden Intan Lampung, Indonesia</dc:rights>
</oai_dc:dc>