Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Radiation Dose Evaluation for Radiotherapy Workers at Unand Hospital Using Four-Element Thermoluminescence Dosimetry

JURNAL ILMIAH PENDIDIKAN FISIKA AL BIRUNI · Vol. 12 No. 2 (2023) · hlm. 143–151

DOI
10.24042/jipfalbiruni.v12i2.18101
ISSN
2503-023X, 2303-1832
Terbit
2023-11-30
Penerbit
Universitas Islam Negeri Raden Intan Lampung, Indonesia
Bahasa
eng

Abstrak

Radiotherapy is a non-surgery therapy that employs ionizing radiation like X-ray or even radiation to cure cancer as a curative activity. Radiation dose rate analysis is required for the person who worked on radiotherapy to strengthen safety precautions for radiation protection, notably in oncology radiation. The research attempted to disclose time trends and radiation dose rate exposure variations among personnel in radiotherapy installation. Radiation dose examination utilizing four-elements TLD received from 16 respondents grouped into six groups (radiation oncologist, medical physicist, radiotherapist, electromedicine, nurse, and sculptor). The number of occupancy exposures rose 55.5% from 2018 to 2022. The most significant annual radiation dose rate for 900 patient workloads attained by medical physicists was 0.996 mSv. In addition, electronics receive the lowest annual radiation dose at Unand Hospital. Annual effective dose exposure by radiation is still safe, below national or international regulations. However, a protective improvement process is vital to limit radiation interaction, particularly for medical physicists, who are the most vulnerable to radiation exposure.

Kata kunci

Jaringan kolaborasi para penulis

25 penulis · 60 tautan kepenulisan bersama · 22 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Andalas University
  • Universitas Jambi
  • Universitas Negeri Padang
  • Bani-Waleed University
  • Universitas Gadjah Mada
  • Badan Pengawas Tenaga Nuklir
  • Rumah Sakit Umum Pusat Dr. M. Djamil Padang
  • Organisasi lain
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Rani DelvihardiniAndalas University2
Ida Bagus Gede Putra PratamaBadan Pengawas Tenaga Nuklir2
Amel OktaviaAndalas University2
Rika AnaliaAndalas University2
Ridwan RidwanSiemens Healthcare (United States)2
Afdhal MuttaqinAndalas University2
Dodi DeviantoAndalas University1
Ridho SaputraAndalas University1
Alvi Khairin NisaAndalas University1
Nia RamadhaniAndalas University1
Fadhilah FitriUniversitas Negeri Padang1
Melin Wanike KetrinUniversitas Negeri Padang1
Sri PurwaningsihUniversitas Jambi1
Hebat Shidow FalahUniversitas Jambi1
Neneng LestariUniversitas Jambi1
Hardiantinus SitinjakUniversitas Jambi1
Kusminarto KusminartoUniversitas Gadjah Mada1
Atika MaulidaAndalas University1
Dina Arfiani RusjdiRumah Sakit Umum Pusat Dr. M. Djamil Padang1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ejournal.radenintan.ac.id/index.php/al-biruni/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Radiation Dose Evaluation for Radiotherapy Workers at Unand Hospital Using Four-Element Thermoluminescence Dosimetry</dc:title>
	<dc:creator xml:lang="en">Fardela, Ramacos</dc:creator>
	<dc:creator xml:lang="en">Milvita, Dian</dc:creator>
	<dc:creator xml:lang="en">Rasyada, Latifah Aulia</dc:creator>
	<dc:creator xml:lang="en">Almuhayar, Mawanda</dc:creator>
	<dc:creator xml:lang="en">Diyona, Fiqi</dc:creator>
	<dc:creator xml:lang="en">Mousa, Almahdi</dc:creator>
	<dc:subject xml:lang="en">Dose Limit</dc:subject>
	<dc:subject xml:lang="en">Radiotherapy</dc:subject>
	<dc:subject xml:lang="en">Radiation Protection</dc:subject>
	<dc:subject xml:lang="en">Occupational Exposure</dc:subject>
	<dc:description xml:lang="en">Radiotherapy is a non-surgery therapy that employs ionizing radiation like X-ray or even radiation to cure cancer as a curative activity. Radiation dose rate analysis is required for the person who worked on radiotherapy to strengthen safety precautions for radiation protection, notably in oncology radiation. The research attempted to disclose time trends and radiation dose rate exposure variations among personnel in radiotherapy installation. Radiation dose examination utilizing four-elements TLD received from 16 respondents grouped into six groups (radiation oncologist, medical physicist, radiotherapist, electromedicine, nurse, and sculptor). The number of occupancy exposures rose 55.5% from 2018 to 2022. The most significant annual radiation dose rate for 900 patient workloads attained by medical physicists was 0.996 mSv. In addition, electronics receive the lowest annual radiation dose at Unand Hospital. Annual effective dose exposure by radiation is still safe, below national or international regulations. However, a protective improvement process is vital to limit radiation interaction, particularly for medical physicists, who are the most vulnerable to radiation exposure.</dc:description>
	<dc:publisher xml:lang="en">Universitas Islam Negeri Raden Intan Lampung, Indonesia</dc:publisher>
	<dc:date>2023-11-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/18101</dc:identifier>
	<dc:identifier>10.24042/jipfalbiruni.v12i2.18101</dc:identifier>
	<dc:source xml:lang="en">Jurnal Ilmiah Pendidikan Fisika Al-Biruni; Vol. 12 No. 2 (2023): Jurnal Ilmiah Pendidikan Fisika Al-Biruni; 143-151</dc:source>
	<dc:source xml:lang="id">Jurnal Ilmiah Pendidikan Fisika Al-Biruni; Vol 12 No 2 (2023): Jurnal Ilmiah Pendidikan Fisika Al-Biruni; 143-151</dc:source>
	<dc:source>2503-023X</dc:source>
	<dc:source>2303-1832</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/18101/pdf</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2023 Physics Education Department, UIN Raden Intan Lampung, Indonesia</dc:rights>
</oai_dc:dc>