Jurnal
SINTA 1
Dosimetric Analysis of 6 MV Energy Photon Radiation Beam on Flatness and Symmetry on Linac in Radiotherapy Installation of UNAND Hospital
JURNAL ILMIAH PENDIDIKAN FISIKA AL BIRUNI · Vol. 13 No. 2 (2024) · hlm. 175–189
ISSN 2503-023X, 2303-1832
Terbit 2024-12-30
Penerbit Universitas Islam Negeri Raden Intan Lampung, Indonesia
Bahasa eng
Abstrak
A dosimetric analysis of a 6 MV photon energy radiation beam on flatness and symmetry in LINAC radiotherapy at UNAND Hospital has been conducted. The aim was to measure the quality of the photon beam using an ion chamber cc 13 detector by observing the beam profile and analyzing the effect of field size and irradiation depth. This study used a blue phantom as the object of irradiation with 6 MV photon energy and variations in irradiation field size. The results showed that the PDD curve at 6 MV energy was by the international standard recommended by BJR-25. Then, the average values of flatness and symmetry in the field area of 10×10 cm2 and 15×15 cm2 are 1.6% and 2.4% for flatness and 2.3% and 1.9% for symmetry. Thus, the dose distribution is more uniform, and both the left and right sides of the profile on the center axis appear balanced, which will help deliver the dose to the patient better. Thus, these values are suitable for clinical use. This study found that the beam profile was larger on the left side of the main axis. This must be considered to ensure the dose distribution complies with the established safety standards. The results also show that variations in the field area and irradiation depth can affect the beam profile, and the resulting flatness and symmetry values are in accordance with the IAEA TRUS-381 and AAPM TG-142 recommendation standards, which are ±2% flatness and ±3% symmetry.
Jaringan kolaborasi para penulis
15 penulis ·
37 tautan kepenulisan bersama
· 16 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Andalas University Siemens Healthcare (United States) Universitas Gadjah Mada Badan Pengawas Tenaga Nuklir Bani-Waleed University Rumah Sakit Umum Pusat Dr. M. Djamil Padang
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ejournal.radenintan.ac.id/index.php/al-biruni/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en">Dosimetric Analysis of 6 MV Energy Photon Radiation Beam on Flatness and Symmetry on Linac in Radiotherapy Installation of UNAND Hospital</dc:title>
<dc:creator xml:lang="en">Analia, Rika</dc:creator>
<dc:creator xml:lang="en">Fardela, Ramacos</dc:creator>
<dc:creator xml:lang="en">Ridwan, Ridwan</dc:creator>
<dc:creator xml:lang="en">Diyona, Fiqi</dc:creator>
<dc:creator xml:lang="en">Muttaqin, Afdhal</dc:creator>
<dc:subject xml:lang="en">LINAC</dc:subject>
<dc:subject xml:lang="en">Dosimetry</dc:subject>
<dc:subject xml:lang="en">Photon Beam</dc:subject>
<dc:subject xml:lang="en">Flatness and Symmetry.</dc:subject>
<dc:description xml:lang="en">A dosimetric analysis of a 6 MV photon energy radiation beam on flatness and symmetry in LINAC radiotherapy at UNAND Hospital has been conducted. The aim was to measure the quality of the photon beam using an ion chamber cc 13 detector by observing the beam profile and analyzing the effect of field size and irradiation depth. This study used a blue phantom as the object of irradiation with 6 MV photon energy and variations in irradiation field size. The results showed that the PDD curve at 6 MV energy was by the international standard recommended by BJR-25. Then, the average values of flatness and symmetry in the field area of 10×10 cm2 and 15×15 cm2 are 1.6% and 2.4% for flatness and 2.3% and 1.9% for symmetry. Thus, the dose distribution is more uniform, and both the left and right sides of the profile on the center axis appear balanced, which will help deliver the dose to the patient better. Thus, these values are suitable for clinical use. This study found that the beam profile was larger on the left side of the main axis. This must be considered to ensure the dose distribution complies with the established safety standards. The results also show that variations in the field area and irradiation depth can affect the beam profile, and the resulting flatness and symmetry values are in accordance with the IAEA TRUS-381 and AAPM TG-142 recommendation standards, which are ±2% flatness and ±3% symmetry.</dc:description>
<dc:publisher xml:lang="en">Universitas Islam Negeri Raden Intan Lampung, Indonesia</dc:publisher>
<dc:date>2024-12-30</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/24016</dc:identifier>
<dc:identifier>10.24042/jipfalbiruni.v13i2.24016</dc:identifier>
<dc:source xml:lang="en">Jurnal Ilmiah Pendidikan Fisika Al-Biruni; Vol. 13 No. 2 (2024): Jurnal Ilmiah Pendidikan Fisika Al-Biruni; 175-189</dc:source>
<dc:source xml:lang="id">Jurnal Ilmiah Pendidikan Fisika Al-Biruni; Vol 13 No 2 (2024): Jurnal Ilmiah Pendidikan Fisika Al-Biruni; 175-189</dc:source>
<dc:source>2503-023X</dc:source>
<dc:source>2303-1832</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/24016/pdf</dc:relation>
<dc:rights xml:lang="en">Copyright (c) 2024 Physics Education Department, UIN Raden Intan Lampung, Indonesia</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Analia, R., Fardela, R., Ridwan, R., Diyona, F., & Muttaqin, A. (2024). Dosimetric Analysis of 6 MV Energy Photon Radiation Beam on Flatness and Symmetry on Linac in Radiotherapy Installation of UNAND Hospital. JURNAL ILMIAH PENDIDIKAN FISIKA AL BIRUNI, 13(2), 175–189. https://doi.org/10.24042/jipfalbiruni.v13i2.24016
Salin
IEEE
R. Analia, R. Fardela, R. Ridwan, F. Diyona, and A. Muttaqin, “Dosimetric Analysis of 6 MV Energy Photon Radiation Beam on Flatness and Symmetry on Linac in Radiotherapy Installation of UNAND Hospital,” JURNAL ILMIAH PENDIDIKAN FISIKA AL BIRUNI, vol. 13, no. 2, pp. 175–189, 2024, doi: 10.24042/jipfalbiruni.v13i2.24016.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.