Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Open-Circuit Voltage Characteristics of Cu–Zn Soil Batteries in Humus, Peat, and Sand: Experimental Comparison and Empirical Regression

JURNAL ILMIAH PENDIDIKAN FISIKA AL BIRUNI · Vol. 14 No. 2 (2025) · hlm. 151–165

DOI
10.24042/jipfalbiruni.v14i2.28494
ISSN
2503-023X, 2303-1832
Terbit
2025-12-20
Penerbit
Universitas Islam Negeri Raden Intan Lampung, Indonesia
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The development of low-cost, sustainable power sources is critical to supporting distributed environmental sensing, agricultural monitoring, and physics education in regions with limited or unreliable access to the grid. This study investigates the open-circuit voltage (OCV) characteristics of Cu–Zn soil batteries embedded in three representative Indonesian soils, humus, peat, and sand, using a 26-cell series–parallel stack under controlled laboratory conditions, along with an empirical logarithmic regression model for electrode sizing. A total of 26 Cu–Zn cells were installed in each soil type, with three independent containers per soil (n = 3) at 25 ± 1 °C; stack OCV was recorded every 5 minutes over 30 minutes, and baseline soil physicochemical properties (moisture, pH, organic C, total N, C/N ratio, and exchangeable Ca, K, and Fe) were characterized to aid interpretation. The results show that humus produced the highest and most stable average stack voltage (9.92 V; range 9.55–10.08 V), followed by peat (8.70 V; 8.50–8.90 V) and sand (6.17 V; 5.99–6.27 V), a ranking consistent with differences in organic matter, acidity, and exchangeable cations rather than directly measured soil electrical conductivity. An empirical logarithmic model linking electrode surface area to OCV, adapted from previous studies and recalibrated for the present configuration, yielded average relative errors of approximately 4–5% within the tested electrode-area range, indicating good agreement between predicted and measured voltages while remaining well below theoretical electrochemical potentials. Within the limitations of short-term, open-circuit measurements without current–voltage or aging tests, these findings identify humus as the most favorable medium among the tested soils for achieving relatively high and stable OCV, and provide an empirically validated framework to support the design and upscaling of Cu–Zn soil battery arrays for sustainable low-power applications in agriculture and physics education.

Kata kunci

Jaringan kolaborasi para penulis

15 penulis · 60 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Telkom University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sussi SussiTelkom University1
Sri AstutiTelkom University1
Nyoman Bogi Aditya KarnaTelkom University1
Nizar Rizky AwanyTelkom University1
Muhammad Fajar FirdiansyahTelkom University1
Rafli Noveri AlfarijiTelkom University1
Dhea Dearly HermanTelkom University1
Muhammad Risqi RisfiandaTelkom University1
Muh NurkhalizTelkom University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ejournal.radenintan.ac.id/index.php/al-biruni/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Open-Circuit Voltage Characteristics of Cu–Zn Soil Batteries in Humus, Peat, and Sand: Experimental Comparison and Empirical Regression</dc:title>
	<dc:creator xml:lang="en">suwandi, suwandi</dc:creator>
	<dc:creator xml:lang="en">Utami, Amaliyah Rohsari Indah </dc:creator>
	<dc:creator xml:lang="en">Fitriyanti, Nurwulan </dc:creator>
	<dc:creator xml:lang="en">Davianti, Ajeng Faradilla Putri </dc:creator>
	<dc:creator xml:lang="en">Ghassani, Deika Saffanah Nisyyah </dc:creator>
	<dc:creator xml:lang="en">Arfandi, Rizky Nurfadillah </dc:creator>
	<dc:subject xml:lang="en">Cu-Zn electrode</dc:subject>
	<dc:subject xml:lang="en">Earth battery</dc:subject>
	<dc:subject xml:lang="en">Logarithmic regression</dc:subject>
	<dc:subject xml:lang="en">Soil conductivity</dc:subject>
	<dc:subject xml:lang="en">Sustainable energy</dc:subject>
	<dc:description xml:lang="en">The development of low-cost, sustainable power sources is critical to supporting distributed environmental sensing, agricultural monitoring, and physics education in regions with limited or unreliable access to the grid. This study investigates the open-circuit voltage (OCV) characteristics of Cu–Zn soil batteries embedded in three representative Indonesian soils, humus, peat, and sand, using a 26-cell series–parallel stack under controlled laboratory conditions, along with an empirical logarithmic regression model for electrode sizing. A total of 26 Cu–Zn cells were installed in each soil type, with three independent containers per soil (n = 3) at 25 ± 1 °C; stack OCV was recorded every 5 minutes over 30 minutes, and baseline soil physicochemical properties (moisture, pH, organic C, total N, C/N ratio, and exchangeable Ca, K, and Fe) were characterized to aid interpretation. The results show that humus produced the highest and most stable average stack voltage (9.92 V; range 9.55–10.08 V), followed by peat (8.70 V; 8.50–8.90 V) and sand (6.17 V; 5.99–6.27 V), a ranking consistent with differences in organic matter, acidity, and exchangeable cations rather than directly measured soil electrical conductivity. An empirical logarithmic model linking electrode surface area to OCV, adapted from previous studies and recalibrated for the present configuration, yielded average relative errors of approximately 4–5% within the tested electrode-area range, indicating good agreement between predicted and measured voltages while remaining well below theoretical electrochemical potentials. Within the limitations of short-term, open-circuit measurements without current–voltage or aging tests, these findings identify humus as the most favorable medium among the tested soils for achieving relatively high and stable OCV, and provide an empirically validated framework to support the design and upscaling of Cu–Zn soil battery arrays for sustainable low-power applications in agriculture and physics education.</dc:description>
	<dc:publisher xml:lang="en">Universitas Islam Negeri Raden Intan Lampung, Indonesia</dc:publisher>
	<dc:date>2025-12-20</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/28494</dc:identifier>
	<dc:identifier>10.24042/jipfalbiruni.v14i2.28494</dc:identifier>
	<dc:source xml:lang="en">Jurnal Ilmiah Pendidikan Fisika Al-Biruni; Vol. 14 No. 2 (2025): Jurnal Ilmiah Pendidikan Fisika Al-Biruni; 151-165</dc:source>
	<dc:source xml:lang="id">Jurnal Ilmiah Pendidikan Fisika Al-Biruni; Vol 14 No 2 (2025): Jurnal Ilmiah Pendidikan Fisika Al-Biruni; 151-165</dc:source>
	<dc:source>2503-023X</dc:source>
	<dc:source>2303-1832</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/28494/10349</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2025 Physics Education Department, UIN Raden Intan Lampung, Indonesia</dc:rights>
	<dc:rights xml:lang="en">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>