Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Characteristic, Behaviour, Lung Function of Workers and PM2,5 Concentration in Cecek Home Industry Sidoarjo Regency

JURNAL KESEHATAN LINGKUNGAN (Journal of Environmental Health) · Vol. 8 No. 1 (2016) · hlm. 128–136

DOI
10.20473/jkl.v8i1.2015.128-136
ISSN
2540-881X, 1829-7285
Terbit
2016-12-20
Penerbit
Universitas Airlangga
Bahasa
eng

Abstrak

Abstract: PM2,5 as one of the air pollutions parameters can be derived from burning wood. Negative impact from PM2,5 exposure on health are impaired lung function. This study was conducted to analyze characteristics, behaviors, lung function of workers and PM2,5 concentration in cecek home industry Katerungan Village, Krian District of Sidoarjo Regency. This research used cross sectional design with total population, 10 workers. Indoor PM2,5 concentration in production area and warehouse space were measured using EPAM 5000 and workers lung function was measured using spirometry test. Individual characteristics and behaviors of workers were analysed using descriptive quantitatively to lung function. Individual characteristics variable consists of age, job tenure, medical history and BMI. Behavioral variables focus on smoking habit. The result of this research showed that PM 2.5 concentration in production area and warehouse space still under the environmental quality standards (< 10 mg/m3). 40% workers in production area and 80% workers in warehouse space got impaired lung function. We can conclude that impaired lung function of workers in cecek home industry Katerungan Village, Krian District of Sidoarjo Regency is not caused of PM2,5 exposure, but job tenure, medical history, BMI, smoking habit for more than 5 years and more than 1 pack per day. Impaired lung function more likely happen to worker with job tenure more than 5 years, having historical respiration disease, having wasted nutritional status and have been smoked more than 5 years and more than 1 pack per day. The suggestion is that workers with impaired lung function should have advanced diagnosis and therapy. For the owner of a home industry, should require his workers wearing masks at work place.Keywords: PM2,5, lung function, cecek home industry

Jaringan kolaborasi para penulis

40 penulis · 132 tautan kepenulisan bersama · 67 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Airlangga
  • Universiti Putra Malaysia
  • Syarif Hidayatullah State Islamic University Jakarta
  • Kementerian Kesehatan Republik Indonesia
  • Jenderal Soedirman University
  • Universitas Jember
  • National University of Malaysia
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Juliana JalaludinUniversiti Putra Malaysia5
Arif SumantriSyarif Hidayatullah State Islamic University Jakarta3
Muhammad Addin RizaldiJenderal Soedirman University2
Globila NurikaUniversitas Jember2
Mochammad SholehhudinUniversitas Airlangga2
Zaneta Aaqilah SalsabilaUniversitas Airlangga2
Zafira Nuha NauraUniversitas Airlangga2
Ririh YudhastutiUniversitas Airlangga2
Lilis SulistyoriniUniversitas Airlangga2
Siti N. A. JauharohSyarif Hidayatullah State Islamic University Jakarta2
Soedjajadi KemanUniversitas Airlangga2
Lian Dwi FibriantiUniversitas Airlangga1
Muhammad SudrajadUniversitas Airlangga1
Mustika Ayu RaharyaningsihUniversitas Airlangga1
Aryatama RahardhimanUniversitas Airlangga1
Rani Ayu WardaniUniversitas Airlangga1
Putri Nabilah RamadhaniUniversitas Airlangga1
Anisa Haq ElhanurUniversitas Airlangga1
Ratih LukmitaraniKementerian Kesehatan Republik Indonesia1
Mufiadzatul ArdiyahKementerian Kesehatan Republik Indonesia1
Corie Indria PrasastiUniversitas Airlangga1
Yuliana SarasatiUniversitas Airlangga1
Zia Azuro ZuhairohUniversitas Airlangga1
Mohd Talib LatifNational University of Malaysia1
Tita Widya ArindayuUniversitas Airlangga1
Shaharuddin Mohd ShamUniversiti Putra Malaysia1
Lovetta Yatta JuanahAfiliasi tidak diketahui1
Ahmadi AhmadiUniversitas Ibnu Sina1
Salsabila Al FirdausiUniversitas Airlangga1
Mohd LatifAfiliasi tidak diketahui1
Nurul QomariahUniversitas Muhammadiyah Jember1
Zida HusninaUniversitas Airlangga1
Suhariono SuharionoRumah Sakit Dokter Soetomo1
Ianatul Ulya DewiUniversitas Airlangga1
Ahmad Zaharin ArisUniversitas Airlangga1
Nanda Inas FauziyahUniversitas Airlangga1
Lailia Ayu RachmawatiUniversitas Airlangga1
Datu Buyung AgusdinataArizona State University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://e-journal.unair.ac.id/JKL/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Characteristic, Behaviour, Lung Function of Workers and PM2,5  Concentration in Cecek Home  Industry Sidoarjo Regency</dc:title>
	<dc:creator>Aulia, Zuhrida</dc:creator>
	<dc:creator>Azizah, R.</dc:creator>
	<dc:description xml:lang="en-US">Abstract: PM2,5   as  one  of the  air pollutions  parameters can  be  derived from burning  wood. Negative impact  from PM2,5  exposure on health are impaired  lung function.  This study  was conducted to analyze  characteristics, behaviors, lung function  of workers  and PM2,5  concentration in cecek home industry Katerungan  Village, Krian District of Sidoarjo Regency. This research used cross sectional design with total population, 10 workers.  Indoor PM2,5 concentration in production area and  warehouse space were  measured using  EPAM 5000  and  workers  lung function  was  measured using spirometry test. Individual characteristics and behaviors of workers  were analysed using descriptive quantitatively to lung  function.  Individual characteristics variable consists of age,  job tenure,  medical history and  BMI. Behavioral variables focus on smoking habit. The result of this research showed that PM 2.5 concentration in production area and warehouse space still under  the environmental quality standards (&amp;lt; 10 mg/m3). 40% workers  in production area and 80% workers  in warehouse space got impaired  lung function.  We can conclude that impaired  lung function  of workers in cecek home industry Katerungan  Village, Krian District of Sidoarjo Regency is not caused of PM2,5 exposure, but job tenure,  medical history, BMI, smoking habit for more than 5 years and more than 1 pack  per day. Impaired lung function more  likely happen to worker with job tenure  more  than 5 years,  having  historical respiration  disease, having  wasted nutritional status  and have been smoked more than 5 years and more than 1 pack  per day. The suggestion is that workers with impaired  lung function  should have  advanced diagnosis and  therapy.  For the owner  of a home industry,  should require his workers wearing  masks at work place.Keywords: PM2,5, lung function,  cecek home industry</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Airlangga</dc:publisher>
	<dc:date>2016-12-20</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://e-journal.unair.ac.id/JKL/article/view/3110</dc:identifier>
	<dc:identifier>10.20473/jkl.v8i1.2015.128-136</dc:identifier>
	<dc:source xml:lang="en-US">JURNAL KESEHATAN LINGKUNGAN ; Vol. 8 No. 1 (2015): Jurnal Kesehatan Lingkungan; 128-136</dc:source>
	<dc:source>2540-881X</dc:source>
	<dc:source>1829-7285</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://e-journal.unair.ac.id/JKL/article/view/3110/2261</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2016 Zuhrida Aulia, R. Azizah</dc:rights>
</oai_dc:dc>