Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Impact Analysis of Noise Intensity with Hearing Loss on Laundry Worker

JURNAL KESEHATAN LINGKUNGAN (Journal of Environmental Health) · Vol. 8 No. 2 (2016) · hlm. 229–237

DOI
10.20473/jkl.v8i2.2016.229-237
ISSN
2540-881X, 1829-7285
Terbit
2016-07-05
Penerbit
Universitas Airlangga
Bahasa
eng

Abstrak

Abstract: Laundry unit at a hospital can be a source of noise. The impact was very dangerous for workers, especially against hearing. From the results of a preliminary survey of the noise intensity measurements obtained intensity noise of 81.2 dB (A). The purpose of this study was to analyze the effects of noise on hearing loss intensity laundry attendant. This study was an observational with cross sectional design. The instrument used was a questionnaire to see the characteristics of the respondent, sound level meter to measure the intensity of noise and audiometry test to measure the threshold of hearing respondents. The research subject as many as 16 workers of laundry. Based on the results of the study states that 75% of the existing work in the laundry unit has a noise intensity exceeds the required value and 12 officers were on the section. The measurement results with minimum of 65.4 dB (A), to a maximum of 84.0 dB( A) andthe average intensity of noise by 79.04 dB (A). Obtained eight workers (50%) had hearing loss right ear and 6 offi cers (37.5%) had hearing loss left ear. There was a relationship between impaired right ear with noise intensity (Spearman; r = 0.577). The need hearing health for periodic examination least once a year, reducing device noise to keep the noise source, and personal protective equipment (PPE).Keywords: hearing loss, intensity noise, laundry

Jaringan kolaborasi para penulis

7 penulis · 12 tautan kepenulisan bersama · 8 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Gadjah Mada
  • Politeknik Negeri Malang
  • Universitas Airlangga
  • Indonesia University of Education
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Suhardi SuhardiUniversitas Gadjah Mada1
Tri MartiniIndonesia University of Education1
Prapto YudonoUniversitas Gadjah Mada1
Bambang Hadi SutrisnoUniversitas Gadjah Mada1
Musholli MusholliPoliteknik Negeri Malang1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://e-journal.unair.ac.id/JKL/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Impact Analysis of Noise Intensity with Hearing Loss on Laundry Worker</dc:title>
	<dc:creator>Dewanty, Rindy Astike</dc:creator>
	<dc:creator>Sudarmaji, Sudarmaji</dc:creator>
	<dc:description xml:lang="en-US">Abstract: Laundry unit at a hospital can be a source of noise. The impact was very dangerous for workers, especially against hearing. From the results of a preliminary survey of the noise intensity measurements obtained intensity noise of 81.2 dB (A). The purpose of this study was to analyze the effects of noise on hearing loss intensity laundry attendant. This study was an observational with cross sectional design. The instrument used was a questionnaire to see the characteristics of the respondent, sound level meter to measure the intensity of noise and audiometry test to measure the threshold of hearing respondents. The research subject as many as 16 workers of laundry. Based on the results of the study states that 75% of the existing work in the laundry unit has a noise intensity exceeds the required value and 12 officers were on the section. The measurement results with minimum of 65.4 dB (A), to a maximum of 84.0 dB( A) andthe average intensity of noise by 79.04 dB (A). Obtained eight workers (50%) had hearing loss right ear and 6 offi cers (37.5%) had hearing loss left ear. There was a relationship between impaired right ear with noise intensity (Spearman; r = 0.577). The need hearing health for periodic examination least once a year, reducing device noise to keep the noise source, and personal protective equipment (PPE).Keywords: hearing loss, intensity noise, laundry</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Airlangga</dc:publisher>
	<dc:date>2016-07-05</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://e-journal.unair.ac.id/JKL/article/view/8016</dc:identifier>
	<dc:identifier>10.20473/jkl.v8i2.2016.229-237</dc:identifier>
	<dc:source xml:lang="en-US">JURNAL KESEHATAN LINGKUNGAN ; Vol. 8 No. 2 (2016): Jurnal Kesehatan Lingkungan; 229-237</dc:source>
	<dc:source>2540-881X</dc:source>
	<dc:source>1829-7285</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://e-journal.unair.ac.id/JKL/article/view/8016/4750</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2018 JURNAL KESEHATAN LINGKUNGAN</dc:rights>
</oai_dc:dc>