Melola Discovery

← Melola Discovery

Jurnal SINTA 1

The Description of Lung Function Status Among Limestone Milling Industry Workers in Tuban Regency

JURNAL KESEHATAN LINGKUNGAN (Journal of Environmental Health) · Vol. 8 No. 2 (2016) · hlm. 238–247

DOI
10.20473/jkl.v8i2.2016.238-247
ISSN
2540-881X, 1829-7285
Terbit
2016-07-05
Penerbit
Universitas Airlangga
Bahasa
eng

Abstrak

Abstract: One of air pollution parameters that are harmful to human health is the amount of dust. The main source of the dust pollutant is a limestone grinding activities. The purpose of this study was to look at the description of workers pulmonary function status, physical quality of the work environment, and respiratory complaints that experienced by workers in the limestone milling industry. This research design was descriptive cross sectional study. All of 12 workers in limestone milling industry were recruited in this study. Physical quality of the environment that have seen was the amount of dust particle, air temperature, humidity, and wind speed. Characteristics and respiratory complaints worker measured by questionnaires. Lung function disorder was measured using spirometry. The result of the physical quality measurement of the environment still met quality standards. Respiratory complaints most experienced by workers was phlegm, cough, cough with phlegm, and cold conditions. A total of 100% workers in production and 83.3% of workers in the packing have impaired lung function. It is concluded that, lung function disorders more experienced workers with the working environment had higher levels of dust and higher temperatures, lower humidity. Judging by the characteristics of workers, impaired lung function more experienced workers by aged 20-29 years and 30-39 years old, have years of service more than 5 years, smoking habits, have normal status nutrition, not wearing protective respiratory tract, and not have a history of lung disease. It is suggested that, the workers with impaired lung function should immediately conductfurther tests to get proper treatment. In addition, workers should always wear respirator while working and quiet from smoking behavior.Keywords: dust particle, lung function status, limestone milling industry workers

Jaringan kolaborasi para penulis

40 penulis · 132 tautan kepenulisan bersama · 67 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Airlangga
  • Universiti Putra Malaysia
  • Syarif Hidayatullah State Islamic University Jakarta
  • Kementerian Kesehatan Republik Indonesia
  • Jenderal Soedirman University
  • Universitas Jember
  • National University of Malaysia
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Juliana JalaludinUniversiti Putra Malaysia5
Arif SumantriSyarif Hidayatullah State Islamic University Jakarta3
Muhammad Addin RizaldiJenderal Soedirman University2
Globila NurikaUniversitas Jember2
Mochammad SholehhudinUniversitas Airlangga2
Zaneta Aaqilah SalsabilaUniversitas Airlangga2
Zafira Nuha NauraUniversitas Airlangga2
Ririh YudhastutiUniversitas Airlangga2
Lilis SulistyoriniUniversitas Airlangga2
Siti N. A. JauharohSyarif Hidayatullah State Islamic University Jakarta2
Soedjajadi KemanUniversitas Airlangga2
Lian Dwi FibriantiUniversitas Airlangga1
Zuhrida AuliaUniversitas Airlangga1
Mustika Ayu RaharyaningsihUniversitas Airlangga1
Aryatama RahardhimanUniversitas Airlangga1
Rani Ayu WardaniUniversitas Airlangga1
Putri Nabilah RamadhaniUniversitas Airlangga1
Anisa Haq ElhanurUniversitas Airlangga1
Ratih LukmitaraniKementerian Kesehatan Republik Indonesia1
Mufiadzatul ArdiyahKementerian Kesehatan Republik Indonesia1
Corie Indria PrasastiUniversitas Airlangga1
Yuliana SarasatiUniversitas Airlangga1
Zia Azuro ZuhairohUniversitas Airlangga1
Mohd Talib LatifNational University of Malaysia1
Tita Widya ArindayuUniversitas Airlangga1
Shaharuddin Mohd ShamUniversiti Putra Malaysia1
Lovetta Yatta JuanahAfiliasi tidak diketahui1
Ahmadi AhmadiUniversitas Ibnu Sina1
Salsabila Al FirdausiUniversitas Airlangga1
Mohd LatifAfiliasi tidak diketahui1
Nurul QomariahUniversitas Muhammadiyah Jember1
Zida HusninaUniversitas Airlangga1
Suhariono SuharionoRumah Sakit Dokter Soetomo1
Ianatul Ulya DewiUniversitas Airlangga1
Ahmad Zaharin ArisUniversitas Airlangga1
Nanda Inas FauziyahUniversitas Airlangga1
Lailia Ayu RachmawatiUniversitas Airlangga1
Datu Buyung AgusdinataArizona State University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://e-journal.unair.ac.id/JKL/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">The Description of Lung Function Status Among Limestone Milling Industry Workers in Tuban Regency</dc:title>
	<dc:creator>Sudrajad, Muhammad</dc:creator>
	<dc:creator>Azizah, R.</dc:creator>
	<dc:description xml:lang="en-US">Abstract: One of air pollution parameters that are harmful to human health is the amount of dust. The main source of the dust pollutant is a limestone grinding activities. The purpose of this study was to look at the description of workers pulmonary function status, physical quality of the work environment, and respiratory complaints that experienced by workers in the limestone milling industry. This research design was descriptive cross sectional study. All of 12 workers in limestone milling industry were recruited in this study. Physical quality of the environment that have seen was the amount of dust particle, air temperature, humidity, and wind speed. Characteristics and respiratory complaints worker measured by questionnaires. Lung function disorder was measured using spirometry. The result of the physical quality measurement of the environment still met quality standards. Respiratory complaints most experienced by workers was phlegm, cough, cough with phlegm, and cold conditions. A total of 100% workers in production and 83.3% of workers in the packing have impaired lung function. It is concluded that, lung function disorders more experienced workers with the working environment had higher levels of dust and higher temperatures, lower humidity. Judging by the characteristics of workers, impaired lung function more experienced workers by aged 20-29 years and 30-39 years old, have years of service more than 5 years, smoking habits, have normal status nutrition, not wearing protective respiratory tract, and not have a history of lung disease. It is suggested that, the workers with impaired lung function should immediately conductfurther tests to get proper treatment. In addition, workers should always wear respirator while working and quiet from smoking behavior.Keywords: dust particle, lung function status, limestone milling industry workers</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Airlangga</dc:publisher>
	<dc:date>2016-07-05</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://e-journal.unair.ac.id/JKL/article/view/8017</dc:identifier>
	<dc:identifier>10.20473/jkl.v8i2.2016.238-247</dc:identifier>
	<dc:source xml:lang="en-US">JURNAL KESEHATAN LINGKUNGAN ; Vol. 8 No. 2 (2016): Jurnal Kesehatan Lingkungan; 238-247</dc:source>
	<dc:source>2540-881X</dc:source>
	<dc:source>1829-7285</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://e-journal.unair.ac.id/JKL/article/view/8017/4751</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2018 JURNAL KESEHATAN LINGKUNGAN</dc:rights>
</oai_dc:dc>