Management of Solid Medical Waste on One of the Covid19 Referral Hospitals in Surabaya, East Java

JURNAL KESEHATAN LINGKUNGAN (Journal of Environmental Health) · Vol. 12 No. 1si (2020) · hlm. 38–44

DOI
10.20473/jkl.v12i1si.2020.38-44
ISSN
2540-881X, 1829-7285
Terbit
2020-09-30
Penerbit
Universitas Airlangga
Bahasa
eng

Abstrak

Introduction: e Covid19 virus has an outer lipid sheath that is not tolerant towards disinfectants, but this virus can quickly infect humans with a fairly high mortality rate. The increasing Covid19 patients directly proportional the amount of solid medical waste production in hospitals. This study aims to identify the health protocol in solid medical waste management in one of the Covid19 patient referral hospitals in Surabaya, East Java. Method: We used descriptive observational research with secondary data for the data compiling method. The obtained data were then compared with the 2020 Guidebook on Waste Management in Referral Hospitals, Emergency Hospitals, and Public Health Centers that Handles Covid19 Patients, issued by the Ministry of Health of the Republic of Indonesia. Result and Discussion: Research results showed that the management of all solid medical waste yielded from the Covid19 Special Isolation Room is directly infectious, went through the incineration process using an incinerator with the primary burner set at 800o C and the secondary burner set at minus 1.000o C. The usage of Personal Protective Equipment (PPE) by medical waste trolley carriers was inappropriate. The officers only used surgical masks, head caps, gloves, shirt, and work shoes, without using any apron. Conclusion: Health protocol for medical waste management in one of the Covid19 patient referral hospitals in Surabaya, East Java has been implemented, but the usage of PPE by medical waste trolley carriers was still inappropriate.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 132 tautan kepenulisan bersama · 67 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Airlangga
  • Universiti Putra Malaysia
  • Syarif Hidayatullah State Islamic University Jakarta
  • Kementerian Kesehatan Republik Indonesia
  • Jenderal Soedirman University
  • Universitas Jember
  • National University of Malaysia
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Juliana JalaludinUniversiti Putra Malaysia5
Arif SumantriSyarif Hidayatullah State Islamic University Jakarta3
Muhammad Addin RizaldiJenderal Soedirman University2
Globila NurikaUniversitas Jember2
Mochammad SholehhudinUniversitas Airlangga2
Zaneta Aaqilah SalsabilaUniversitas Airlangga2
Zafira Nuha NauraUniversitas Airlangga2
Ririh YudhastutiUniversitas Airlangga2
Lilis SulistyoriniUniversitas Airlangga2
Siti N. A. JauharohSyarif Hidayatullah State Islamic University Jakarta2
Soedjajadi KemanUniversitas Airlangga2
Lian Dwi FibriantiUniversitas Airlangga1
Zuhrida AuliaUniversitas Airlangga1
Muhammad SudrajadUniversitas Airlangga1
Mustika Ayu RaharyaningsihUniversitas Airlangga1
Aryatama RahardhimanUniversitas Airlangga1
Putri Nabilah RamadhaniUniversitas Airlangga1
Anisa Haq ElhanurUniversitas Airlangga1
Ratih LukmitaraniKementerian Kesehatan Republik Indonesia1
Mufiadzatul ArdiyahKementerian Kesehatan Republik Indonesia1
Corie Indria PrasastiUniversitas Airlangga1
Yuliana SarasatiUniversitas Airlangga1
Zia Azuro ZuhairohUniversitas Airlangga1
Mohd Talib LatifNational University of Malaysia1
Tita Widya ArindayuUniversitas Airlangga1
Shaharuddin Mohd ShamUniversiti Putra Malaysia1
Lovetta Yatta JuanahAfiliasi tidak diketahui1
Ahmadi AhmadiUniversitas Ibnu Sina1
Salsabila Al FirdausiUniversitas Airlangga1
Mohd LatifAfiliasi tidak diketahui1
Nurul QomariahUniversitas Muhammadiyah Jember1
Zida HusninaUniversitas Airlangga1
Suhariono SuharionoRumah Sakit Dokter Soetomo1
Ianatul Ulya DewiUniversitas Airlangga1
Ahmad Zaharin ArisUniversitas Airlangga1
Nanda Inas FauziyahUniversitas Airlangga1
Lailia Ayu RachmawatiUniversitas Airlangga1
Datu Buyung AgusdinataArizona State University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://e-journal.unair.ac.id/JKL/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Management of Solid Medical Waste on One of the Covid19 Referral Hospitals in Surabaya, East Java</dc:title>
	<dc:creator>Wardani, Rani Ayu</dc:creator>
	<dc:creator>Azizah, R.</dc:creator>
	<dc:subject xml:lang="en-US">COVID-19</dc:subject>
	<dc:subject xml:lang="en-US">COVID-19 referral hospitals</dc:subject>
	<dc:subject xml:lang="en-US">solid medical waste</dc:subject>
	<dc:description xml:lang="en-US">Introduction: e Covid19 virus has an outer lipid sheath that is not tolerant towards disinfectants, but this virus can quickly infect humans with a fairly high mortality rate. The increasing Covid19 patients directly proportional the amount of solid medical waste production in hospitals. This study aims to identify the health protocol in solid medical waste management in one of the Covid19 patient referral hospitals in Surabaya, East Java. Method: We used descriptive observational research with secondary data for the data compiling method. The obtained data were then compared with the 2020 Guidebook on Waste Management in Referral Hospitals, Emergency Hospitals, and Public Health Centers that Handles Covid19 Patients, issued by the Ministry of Health of the Republic of Indonesia. Result and Discussion: Research results showed that the management of all solid medical waste yielded from the Covid19 Special Isolation Room is directly infectious, went through the incineration process using an incinerator with the primary burner set at 800o C and the secondary burner set at minus 1.000o C. The usage of Personal Protective Equipment (PPE) by medical waste trolley carriers was inappropriate. The officers only used surgical masks, head caps, gloves, shirt, and work shoes, without using any apron. Conclusion: Health protocol for medical waste management in one of the Covid19 patient referral hospitals in Surabaya, East Java has been implemented, but the usage of PPE by medical waste trolley carriers was still inappropriate.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Airlangga</dc:publisher>
	<dc:date>2020-09-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://e-journal.unair.ac.id/JKL/article/view/20967</dc:identifier>
	<dc:identifier>10.20473/jkl.v12i1si.2020.38-44</dc:identifier>
	<dc:source xml:lang="en-US">JURNAL KESEHATAN LINGKUNGAN ; Vol. 12 No. 1si (2020): SPECIAL ISSUE; 38-44</dc:source>
	<dc:source>2540-881X</dc:source>
	<dc:source>1829-7285</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://e-journal.unair.ac.id/JKL/article/view/20967/12286</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 JURNAL KESEHATAN LINGKUNGAN</dc:rights>
</oai_dc:dc>