Akses terbuka
Jurnal
SINTA 1
Drinking Water Quality of Water Refill Station in Gebang Raya Tanggerang
JURNAL KESEHATAN LINGKUNGAN (Journal of Environmental Health) · Vol. 15 No. 2 (2023) · hlm. 120–126
ISSN 2540-881X, 1829-7285
Terbit 2023-04-29
Penerbit Universitas Airlangga
Bahasa eng
Abstrak
Introduction: As a drinking water provider, refill drinking water station must comply with hygiene and sanitation standards for water quality, including the microbiological value standard for clean water. This study was conducted to determine the microbial levels in refill drinking water station and analyze the drinking water quality based on sanitation hygiene observations. Methods: The study included laboratory test methods, cross-sectional analysis tests, and a descriptive analysis. Drinking water sampling and sanitation observations were performed using the total sampling technique on 17 water station. As much as 100 ml of drinking water samples were taken directly from the faucet to refill water with a sterile bottle container. Sanitary hygiene was studied through interviews using an observation sheet. Results and Discussion: The most bacteria were found at 108 per 100ml in Escherichia coli parameters and 866 per 100ml in coliform parameters in the station water samples with the Station 8 (SK) code. The interviews showed that seven station did not meet the criteria for good sanitation hygiene. Conclusion: Sanitary hygiene is carried out to reduce or eliminate bacterial contamination in drinking water. Observations and laboratory tests show that good sanitation is related to drinking water quality.
Jaringan kolaborasi para penulis
5 penulis ·
7 tautan kepenulisan bersama
· 3 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Universitas Esa Unggul Universitas Respati Indonesia
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://e-journal.unair.ac.id/JKL/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Drinking Water Quality of Water Refill Station in Gebang Raya Tanggerang</dc:title>
<dc:creator>Azteria, Veza</dc:creator>
<dc:creator>Rosya, Ernalinda </dc:creator>
<dc:subject xml:lang="en-US">Drinking water station</dc:subject>
<dc:subject xml:lang="en-US">Microbiology</dc:subject>
<dc:subject xml:lang="en-US">Personal hygiene</dc:subject>
<dc:subject xml:lang="en-US">Sanitary hygiene</dc:subject>
<dc:description xml:lang="en-US">Introduction: As a drinking water provider, refill drinking water station must comply with hygiene and sanitation standards for water quality, including the microbiological value standard for clean water. This study was conducted to determine the microbial levels in refill drinking water station and analyze the drinking water quality based on sanitation hygiene observations. Methods: The study included laboratory test methods, cross-sectional analysis tests, and a descriptive analysis. Drinking water sampling and sanitation observations were performed using the total sampling technique on 17 water station. As much as 100 ml of drinking water samples were taken directly from the faucet to refill water with a sterile bottle container. Sanitary hygiene was studied through interviews using an observation sheet. Results and Discussion: The most bacteria were found at 108 per 100ml in Escherichia coli parameters and 866 per 100ml in coliform parameters in the station water samples with the Station 8 (SK) code. The interviews showed that seven station did not meet the criteria for good sanitation hygiene. Conclusion: Sanitary hygiene is carried out to reduce or eliminate bacterial contamination in drinking water. Observations and laboratory tests show that good sanitation is related to drinking water quality.</dc:description>
<dc:publisher xml:lang="en-US">Universitas Airlangga</dc:publisher>
<dc:date>2023-04-29</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:format>text/xml</dc:format>
<dc:identifier>https://e-journal.unair.ac.id/JKL/article/view/42203</dc:identifier>
<dc:identifier>10.20473/jkl.v15i2.2023.120-126</dc:identifier>
<dc:source xml:lang="en-US">JURNAL KESEHATAN LINGKUNGAN ; Vol. 15 No. 2 (2023): JURNAL KESEHATAN LINGKUNGAN; 120-126</dc:source>
<dc:source>2540-881X</dc:source>
<dc:source>1829-7285</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://e-journal.unair.ac.id/JKL/article/view/42203/24469</dc:relation>
<dc:relation>https://e-journal.unair.ac.id/JKL/article/view/42203/24470</dc:relation>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Azteria, V., & Rosya, E. (2023). Drinking Water Quality of Water Refill Station in Gebang Raya Tanggerang. JURNAL KESEHATAN LINGKUNGAN (Journal of Environmental Health), 15(2), 120–126. https://doi.org/10.20473/jkl.v15i2.2023.120-126
Salin
IEEE
V. Azteria and E. Rosya, “Drinking Water Quality of Water Refill Station in Gebang Raya Tanggerang,” JURNAL KESEHATAN LINGKUNGAN (Journal of Environmental Health), vol. 15, no. 2, pp. 120–126, 2023, doi: 10.20473/jkl.v15i2.2023.120-126.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.