Identification of Airborne Aerobic Bacteria in the Intensive Care Room using MALDI-TOF MS

JURNAL KESEHATAN LINGKUNGAN (Journal of Environmental Health) · Vol. 16 No. 1 (2024) · hlm. 68–75

DOI
10.20473/jkl.v16i1.2024.68-75
ISSN
2540-881X, 1829-7285
Terbit
2024-01-29
Penerbit
Universitas Airlangga
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0

Abstrak

Introduction: Indoor air quality can affect the spread of airborne microorganisms which can lead to healthcare-associated infections (HAIs). The quality and quantity of airborne microorganisms are responsible for mortality and morbidity in infection-prone hosts such as patients admitted to the intensive care unit (ICU). The research aims to determine the quality of microorganisms in the air, identify the types of aerobic bacteria, and assess the physical parameters of the air in the ICU. Methods: This study was a cross-sectional study with a descriptive observational method. Air specimens were collected using the MAS-100 NT tool with blood agar plate solid culture media, which then incubated in an aerobic atmosphere for 24 hours at 37±2°C. Observation and measurement of air microbiological quality was by counting the number of microorganisms in CFU/m3 and identification of bacteria using MALDI-TOF MS. Results and Discussion: The maximum concentration of microorganisms in the air exceeds the standard value, and the average value of the concentration of microorganisms in the air is 736 CFU/m3. The most common types of aerobic bacteria in the air were Bacillus sp. (n=12), Coagulase-negative Staphylococci (n=5), and Staphylococcus aureus (n=5). There was an increase in physical parameters in the form of average temperature (26.24°C) and humidity (70%) with a ventilation system and air regulation using mechanical ventilation sourced from a split air conditioner with an exhaust fan without a high-efficiency particulate-absorbing (HEPA) filter. Conclusion: Low indoor air quality has the potential to increase the concentration of microorganisms and bacterial findings in the air

Kata kunci

Jaringan kolaborasi para penulis

22 penulis · 54 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Hasanuddin University
  • Universitas Gadjah Mada
  • Bandung Institute of Technology
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Rosana AgusHasanuddin University2
Martira MaddeppungengHasanuddin University1
Andi Alfia Muthmainnah TanraHasanuddin University1
Ema AlasiryHasanuddin University1
Suryani TawaliHasanuddin University1
Yani Ringan RundeAfiliasi tidak diketahui1
Andi Riza Safitri Hadiratul KudsiahHasanuddin University1
Muh. Nasrum MassiAfiliasi tidak diketahui1
Andi Nur AsrinawatyHasanuddin University1
Firdaus HamidHasanuddin University1
Wahyunita Do TokaHasanuddin University1
Dhian Karina Aprilani HattahHasanuddin University1
Sriwijaya SriwijayaAfiliasi tidak diketahui1
Ian Imanuel FidhatamiUniversitas Gadjah Mada1
SjafaraenanHasanuddin University1
Yulianti SamaraBandung Institute of Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://e-journal.unair.ac.id/JKL/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Identification of Airborne Aerobic Bacteria in the Intensive Care Room using MALDI-TOF MS</dc:title>
	<dc:creator>Palulun, Prajayanti</dc:creator>
	<dc:creator>Rasita, Yoeke Dewi</dc:creator>
	<dc:creator>Massi, Muhammad Nasrum</dc:creator>
	<dc:creator>Sjahril, Rizalinda </dc:creator>
	<dc:creator>Katu, Sudirman</dc:creator>
	<dc:creator>Pattelongi, Ilhamjaya</dc:creator>
	<dc:subject xml:lang="en-US">Aerobic bacteria</dc:subject>
	<dc:subject xml:lang="en-US">Air quality</dc:subject>
	<dc:subject xml:lang="en-US">MALDI-TOF MS</dc:subject>
	<dc:subject xml:lang="en-US">MAS</dc:subject>
	<dc:description xml:lang="en-US">Introduction: Indoor air quality can affect the spread of airborne microorganisms which can lead to healthcare-associated infections (HAIs). The quality and quantity of airborne microorganisms are responsible for mortality and morbidity in infection-prone hosts such as patients admitted to the intensive care unit (ICU). The research aims to determine the quality of microorganisms in the air, identify the types of aerobic bacteria, and assess the physical parameters of the air in the ICU. Methods: This study was a cross-sectional study with a descriptive observational method. Air specimens were collected using the MAS-100 NT tool with blood agar plate solid culture media, which then incubated in an aerobic atmosphere for 24 hours at 37±2°C. Observation and measurement of air microbiological quality was by counting the number of microorganisms in CFU/m3 and identification of bacteria using MALDI-TOF MS. Results and Discussion: The maximum concentration of microorganisms in the air exceeds the standard value, and the average value of the concentration of microorganisms in the air is 736 CFU/m3. The most common types of aerobic bacteria in the air were Bacillus sp. (n=12), Coagulase-negative Staphylococci (n=5), and Staphylococcus aureus (n=5). There was an increase in physical parameters in the form of average temperature (26.24°C) and humidity (70%) with a ventilation system and air regulation using mechanical ventilation sourced from a split air conditioner with an exhaust fan without a high-efficiency particulate-absorbing (HEPA) filter. Conclusion: Low indoor air quality has the potential to increase the concentration of microorganisms and bacterial findings in the air</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Airlangga</dc:publisher>
	<dc:date>2024-01-29</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:format>text/xml</dc:format>
	<dc:identifier>https://e-journal.unair.ac.id/JKL/article/view/46786</dc:identifier>
	<dc:identifier>10.20473/jkl.v16i1.2024.68-75</dc:identifier>
	<dc:source xml:lang="en-US">JURNAL KESEHATAN LINGKUNGAN ; Vol. 16 No. 1 (2024): JURNAL KESEHATAN LINGKUNGAN; 68-75</dc:source>
	<dc:source>2540-881X</dc:source>
	<dc:source>1829-7285</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://e-journal.unair.ac.id/JKL/article/view/46786/27835</dc:relation>
	<dc:relation>https://e-journal.unair.ac.id/JKL/article/view/46786/27836</dc:relation>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>