Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Finite Element Analysis and Fabrication of Voronoi Perforated Wrist Hand Orthosis Based on Reverse Engineering Modelling Method

Journal of Applied Engineering and Technological Science (JAETS) · Vol. 4 No. 1 (2022) · hlm. 451–459

DOI
10.37385/jaets.v4i1.1199
ISSN
2715-6079, 2715-6087
Terbit
2022-12-08
Penerbit
Yayasan Riset dan Pengembangan Intelektual (YRPI)
Bahasa
en

Abstrak

Other than surgery, post-stroke spasticity, fractures due to accidents, sports injuries, and musculoskeletal disorders due to office work on the wrist can be treated using a wrist-hand orthosis. The customized conventional methods usually have some drawbacks, which are more expensive, take a long time to manufacture, and require expert skills from medical therapists. The presence of reverse engineering (RE) technology can be applied in the medical field, such as the manufacture of prosthetic or orthosis devices. This study aims to develop a reverse engineering-based wrist-hand orthosis design, analyze it using the finite element method, and fabricate it. Research methods included 3D scanning, CAD modelling, model analysis, 3D printing, and postprocessing. The model material used was PLA with variations in the thickness of 5 mm, 5.5 mm, and 6 mm, and the load values range from 0 N to 30 N. The results of the equivalent stress analysis showed that the 5 mm thickness model could withstand a load of 30 N with a maximum equivalent stress of 23.46 MPa. With a safety factor value of 2.56, it was still relatively safe, and a critical area was at the back end of the model's palm between the thumb and index finger. The equivalent elastic strain and deformation results also had the same graphic trend with the maximum values for the same model, which were 0.0076 mm and 0.614 mm, respectively. The 3D printing FDM result showed that the Voronoi perforated wrist-hand orthosis prototype was sturdy, fit, and comfortable. It is expected to hold muscle tone and immobilize for hand rehabilitation.

Kata kunci

Jaringan kolaborasi para penulis

28 penulis · 74 tautan kepenulisan bersama · 34 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Politeknik Negeri Malang
  • University of Sarjanawiyata Tamansiswa
  • Universitas Negeri Padang
  • Politeknik Pertanian Negeri Pangkajene Kepulauan
  • State University of Malang
  • Politeknik Negeri Semarang
  • Politeknik Negeri Banyuwangi
  • Organisasi lain
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ratna MonasariPoliteknik Negeri Malang8
Ali Sai’inPoliteknik Negeri Semarang5
Andre KurniawanUniversitas Negeri Padang4
Fina Andika Frida AstutiPoliteknik Negeri Malang3
Ahmad Hanif FirdausPoliteknik Negeri Malang3
Moh. HartonoPoliteknik Negeri Malang3
Moh. Nasir HariyantoPoliteknik Negeri Malang3
Fataa KusumattaqiinPoliteknik Negeri Samarinda3
Rangga E. SantosoCranfield University3
Lutfi HakimPoliteknik Negeri Banyuwangi2
Muhammad RiyadiPoliteknik Pertanian Negeri Pangkajene Kepulauan1
Irawan IlhamPoliteknik Pertanian Negeri Pangkajene Kepulauan1
Eko Sulkhany YuliantoUniversity of Sarjanawiyata Tamansiswa1
Tito Aji MilleniawanUniversity of Sarjanawiyata Tamansiswa1
Mohammad Ahyar Syafwan LysanderUniversity of Sarjanawiyata Tamansiswa1
Shahnur Al-HafriUniversity of Sarjanawiyata Tamansiswa1
Didik SubiyantoUniversity of Sarjanawiyata Tamansiswa1
Tri Aji PurnomoUniversity of Sarjanawiyata Tamansiswa1
Poppy PuspitasariState University of Malang1
Putut MurdantoState University of Malang1
Mohammad Sugi HartonoPoliteknik Negeri Malang1
Remon LapisaUniversitas Negeri Padang1
Jasman JasmanUniversitas Negeri Padang1
Zainal AbadiUniversitas Negeri Padang1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.yrpipku.com/index.php/jaets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 9 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Finite Element Analysis and Fabrication of Voronoi Perforated Wrist Hand Orthosis Based on Reverse Engineering Modelling Method</dc:title>
	<dc:creator xml:lang="en">Emzain, Zakki Fuadi</dc:creator>
	<dc:creator xml:lang="en">Qosim, Nanang</dc:creator>
	<dc:creator xml:lang="en">Mufarrih, AM.</dc:creator>
	<dc:creator xml:lang="en">Hadi, Syamsul</dc:creator>
	<dc:subject xml:lang="en">Finite Element Analysis</dc:subject>
	<dc:subject xml:lang="en">Reverse Engineering</dc:subject>
	<dc:subject xml:lang="en">Wrist-Hand Orthosis</dc:subject>
	<dc:subject xml:lang="en">Voronoi Perforated</dc:subject>
	<dc:description xml:lang="en">Other than surgery, post-stroke spasticity, fractures due to accidents, sports injuries, and musculoskeletal disorders due to office work on the wrist can be treated using a wrist-hand orthosis. The customized conventional methods usually have some drawbacks, which are more expensive, take a long time to manufacture, and require expert skills from medical therapists. The presence of reverse engineering (RE) technology can be applied in the medical field, such as the manufacture of prosthetic or orthosis devices. This study aims to develop a reverse engineering-based wrist-hand orthosis design, analyze it using the finite element method, and fabricate it. Research methods included 3D scanning, CAD modelling, model analysis, 3D printing, and postprocessing. The model material used was PLA with variations in the thickness of 5 mm, 5.5 mm, and 6 mm, and the load values range from 0 N to 30 N. The results of the equivalent stress analysis showed that the 5 mm thickness model could withstand a load of 30 N with a maximum equivalent stress of 23.46 MPa. With a safety factor value of 2.56, it was still relatively safe, and a critical area was at the back end of the model's palm between the thumb and index finger. The equivalent elastic strain and deformation results also had the same graphic trend with the maximum values for the same model, which were 0.0076 mm and 0.614 mm, respectively. The 3D printing FDM result showed that the Voronoi perforated wrist-hand orthosis prototype was sturdy, fit, and comfortable. It is expected to hold muscle tone and immobilize for hand rehabilitation. </dc:description>
	<dc:publisher xml:lang="en">Yayasan Riset dan Pengembangan Intelektual (YRPI)</dc:publisher>
	<dc:date>2022-12-08</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.yrpipku.com/index.php/jaets/article/view/1199</dc:identifier>
	<dc:identifier>10.37385/jaets.v4i1.1199</dc:identifier>
	<dc:source xml:lang="en">Journal of Applied Engineering and Technological Science (JAETS); Vol. 4 No. 1 (2022): Journal of Applied Engineering and Technological Science (JAETS); 451-459</dc:source>
	<dc:source>2715-6079</dc:source>
	<dc:source>2715-6087</dc:source>
	<dc:source>10.37385/jaets.v4i1</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://journal.yrpipku.com/index.php/jaets/article/view/1199/891</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2022 Journal of Applied Engineering and Technological Science (JAETS)</dc:rights>
</oai_dc:dc>