Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Microcontroller-Based Intravenous Fluid Monitoring System Design

Journal of Applied Engineering and Technological Science (JAETS) · Vol. 5 No. 2 (2024) · hlm. 649–660

DOI
10.37385/jaets.v5i2.3230
ISSN
2715-6079, 2715-6087
Terbit
2024-06-06
Penerbit
Yayasan Riset dan Pengembangan Intelektual (YRPI)
Bahasa
en

Abstrak

Intravenous fluids are used to replace the body's fluid and electrolyte balance. This is a crucial need for a patient during treatment, so infusion replacement should not be delayed as it can be fatal to the patient. Medical personnel must always pay attention to the patient's infusion. This has always been a problem because the limited number of medical personnel and the large number of patients often make it difficult for medical personnel to carry out their duties. The development of technology increases human creativity and creates various tools to help humans be more effective, including in dealing with problems in the medical world. Based on this background, the author designed an infusion fluid monitoring system to facilitate nurses in hospitals that lack electrical support and internet networks. This research aims to make an intravenous fluid monitoring tool using a microcontroller effectively and realtime. The research method we use is research and development, while the data analysis method uses comparative quantitative analysis. This research consists of three main parts, namely system input, microcontroller as system processor, and system output as expected. This infusion fluid monitoring uses Load Cell to measure the volume of infusion fluid, RTC module to estimate the time of infusion fluid expiration, LCD as infusion fluid status information, and buzzer as an information alarm if the infusion fluid is detected to run out. The microcontroller used in this research is Arduino Uno. The results showed that infusion fluid has the same pressure as human body fluids (isotonic). Load Cell has a mass reading accuracy value of 99.88%, the accuracy of testing the conversion of intravenous fluid measurements into milliliters of 99.49%, and the number of infusion fluid droplets per minute under normal conditions is 20, with an estimated time out for 8 hours.

Kata kunci

Jaringan kolaborasi para penulis

22 penulis · 62 tautan kepenulisan bersama · 15 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Ahmad Dahlan
  • Universitas Gadjah Mada
  • National Research and Innovation Agency
  • Taipei Medical University
  • Universiti Teknikal Malaysia Melaka
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Tole SutiknoUniversitas Ahmad Dahlan4
Nurmalasari NurmalasariAfiliasi tidak diketahui2
Hendril Satrian PurnamaAfiliasi tidak diketahui2
Anggit PamungkasAfiliasi tidak diketahui2
Ratu MatahariUniversitas Ahmad Dahlan2
Riza Fatma ArifaNational Research and Innovation Agency2
Pairote ChakranonTaipei Medical University2
Watra ArsadiandoAfiliasi tidak diketahui2
Zakky Ahmad Ikhsan MAfiliasi tidak diketahui1
Muslih Rayullan FeterAfiliasi tidak diketahui1
Rizki FernandoUniversitas Ahmad Dahlan1
Syariatul DirgantaraUniversitas Ahmad Dahlan1
Sunardi SunardiUniversitas Ahmad Dahlan1
Arsyad Cahya SubrataUniversitas Ahmad Dahlan1
Mohd Hatta JopriUniversiti Teknikal Malaysia Melaka1
Tri WahonoUniversitas Ahmad Dahlan1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.yrpipku.com/index.php/jaets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Microcontroller-Based Intravenous Fluid Monitoring System Design</dc:title>
	<dc:creator xml:lang="en">Rosyady, Phisca Aditya</dc:creator>
	<dc:creator xml:lang="en">Habibah, Nurina Umy</dc:creator>
	<dc:creator xml:lang="en">Baswara, Ahmad Raditya Cahya</dc:creator>
	<dc:creator xml:lang="en">Ihsana, Nuni</dc:creator>
	<dc:creator xml:lang="en">Sulistiawan, Dedik</dc:creator>
	<dc:creator xml:lang="en">Dinata, Widya Rahayu</dc:creator>
	<dc:subject xml:lang="en">Load Cell</dc:subject>
	<dc:subject xml:lang="en">RTC</dc:subject>
	<dc:subject xml:lang="en">Intravenous Monitoring</dc:subject>
	<dc:subject xml:lang="en">Buzzer</dc:subject>
	<dc:description xml:lang="en">Intravenous fluids are used to replace the body's fluid and electrolyte balance. This is a crucial need for a patient during treatment, so infusion replacement should not be delayed as it can be fatal to the patient. Medical personnel must always pay attention to the patient's infusion. This has always been a problem because the limited number of medical personnel and the large number of patients often make it difficult for medical personnel to carry out their duties. The development of technology increases human creativity and creates various tools to help humans be more effective, including in dealing with problems in the medical world. Based on this background, the author designed an infusion fluid monitoring system to facilitate nurses in hospitals that lack electrical support and internet networks. This research aims to make an intravenous fluid monitoring tool using a microcontroller effectively and realtime. The research method we use is research and development, while the data analysis method uses comparative quantitative analysis. This research consists of three main parts, namely system input, microcontroller as system processor, and system output as expected. This infusion fluid monitoring uses Load Cell to measure the volume of infusion fluid, RTC module to estimate the time of infusion fluid expiration, LCD as infusion fluid status information, and buzzer as an information alarm if the infusion fluid is detected to run out. The microcontroller used in this research is Arduino Uno. The results showed that infusion fluid has the same pressure as human body fluids (isotonic). Load Cell has a mass reading accuracy value of 99.88%, the accuracy of testing the conversion of intravenous fluid measurements into milliliters of 99.49%, and the number of infusion fluid droplets per minute under normal conditions is 20, with an estimated time out for 8 hours.</dc:description>
	<dc:publisher xml:lang="en">Yayasan Riset dan Pengembangan Intelektual (YRPI)</dc:publisher>
	<dc:date>2024-06-06</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.yrpipku.com/index.php/jaets/article/view/3230</dc:identifier>
	<dc:identifier>10.37385/jaets.v5i2.3230</dc:identifier>
	<dc:source xml:lang="en">Journal of Applied Engineering and Technological Science (JAETS); Vol. 5 No. 2 (2024): Journal of Applied Engineering and Technological Science (JAETS); 649-660</dc:source>
	<dc:source>2715-6079</dc:source>
	<dc:source>2715-6087</dc:source>
	<dc:source>10.37385/jaets.v5i2</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://journal.yrpipku.com/index.php/jaets/article/view/3230/2878</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2024 Journal of Applied Engineering and Technological Science (JAETS)</dc:rights>
</oai_dc:dc>