Melola Discovery

← Melola Discovery

Jurnal SINTA 1

A Non-Contact Height Measurement Method Using Mediapipe and Yolov8 in a Three-Dimension Space

Journal of Applied Engineering and Technological Science (JAETS) · Vol. 7 No. 2 (2026) · hlm. 1703–1718

DOI
10.37385/jaets.v7i2.8798
ISSN
2715-6079, 2715-6087
Terbit
2026-06-18
Penerbit
Yayasan Riset dan Pengembangan Intelektual (YRPI)
Bahasa
en

Abstrak

Accurate human height measurement is an essential clinical parameter for calculating body mass index and assessing patient health status. However, traditional contact-based or manual methods are impractical for patients with limited mobility or during emergency conditions. This study addresses this limitation by developing a non-contact 3D height estimation system using a smartphone-based vision approach. The system employs MediaPipe to extract skeletal landmarks and a regression model to predict human height from bone segment lengths and a reference object. Experimental evaluation on 166 subjects across multiple positions demonstrates a high accuracy with an average error rate of 1.54 ± 0.64%, outperforming most existing camera-based systems. The proposed method offers a practical, low-cost, and portable solution for medical height assessment, particularly beneficial in clinical and emergency settings. Potential limitations include dependence on camera angle and lighting conditions, which will be addressed in future work.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Hanoi University of Science and Technology
  • Hanoi University of Industry
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.yrpipku.com/index.php/jaets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">A Non-Contact Height Measurement Method Using Mediapipe and Yolov8 in a Three-Dimension Space</dc:title>
	<dc:creator xml:lang="en">Nguyen Trung, Phu</dc:creator>
	<dc:creator xml:lang="en">Dong Quoc, Dat</dc:creator>
	<dc:creator xml:lang="en">Nguyen Phan, Kien</dc:creator>
	<dc:subject xml:lang="en">non-contact</dc:subject>
	<dc:subject xml:lang="en">mediaPipe</dc:subject>
	<dc:subject xml:lang="en">3D space</dc:subject>
	<dc:subject xml:lang="en">height measurement</dc:subject>
	<dc:description xml:lang="en">Accurate human height measurement is an essential clinical parameter for calculating body mass index and assessing patient health status. However, traditional contact-based or manual methods are impractical for patients with limited mobility or during emergency conditions. This study addresses this limitation by developing a non-contact 3D height estimation system using a smartphone-based vision approach. The system employs MediaPipe to extract skeletal landmarks and a regression model to predict human height from bone segment lengths and a reference object. Experimental evaluation on 166 subjects across multiple positions demonstrates a high accuracy with an average error rate of 1.54 ± 0.64%, outperforming most existing camera-based systems. The proposed method offers a practical, low-cost, and portable solution for medical height assessment, particularly beneficial in clinical and emergency settings. Potential limitations include dependence on camera angle and lighting conditions, which will be addressed in future work.</dc:description>
	<dc:publisher xml:lang="en">Yayasan Riset dan Pengembangan Intelektual (YRPI)</dc:publisher>
	<dc:date>2026-06-18</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.yrpipku.com/index.php/jaets/article/view/8798</dc:identifier>
	<dc:identifier>10.37385/jaets.v7i2.8798</dc:identifier>
	<dc:source xml:lang="en">Journal of Applied Engineering and Technological Science (JAETS); Vol. 7 No. 2 (2026): Journal of Applied Engineering and Technological Science (JAETS); 1703-1718</dc:source>
	<dc:source>2715-6079</dc:source>
	<dc:source>2715-6087</dc:source>
	<dc:source>10.37385/jaets.v7i2</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://journal.yrpipku.com/index.php/jaets/article/view/8798/6446</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2026 Phu Nguyen Trung, Dat Dong Quoc, Kien Nguyen Phan</dc:rights>
</oai_dc:dc>