Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Leaching response of coastal sandy soils to subsurface hybrid ameliorant layering across homogeneous land units

Journal of Degraded and Mining Lands Management · Vol. 13 No. 3 (2026) · hlm. 10851–10858

DOI
10.15243/jdmlm.2026.133.10851
ISSN
2502-2458, 2339-076X
Terbit
2026-07-01
Penerbit
Brawijaya University
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-nc/4.0

Abstrak

Sandy soil is characterized by a coarse texture, low organic content, low water-holding capacity, and rapid leaching. Soil amendments are usually applied to improve soil physicochemical characteristics, but their effects are only short-term. Subsurface hybrid ameliorant layering has been proposed as a means to reduce leaching in sandy soils. This study evaluated the leaching responses to subsurface hybrid ameliorant placement within the soil, using a soil column experiment with two factors: kinds of HLU (Homogeneous Land Unit) as the first factor, which consisted of eight HLUs, and ameliorant placement treatments as the second factor, which consisted of control treatment, conventional placement, and subsurface placement. The leaching response parameters were cumulative leachate volume and the differences in organic carbon, nitrogen, and phosphorus concentrations between the upper and bottom layers. The results showed that subsurface placement can reduce the cumulative leachate volume and increase N concentration in the upper layer after the incubation period, but did not significantly affect organic carbon or phosphorus availability in either layer. The application of this treatment resulted in different responses among HLUs, which were influenced by the natural physicochemical characteristics of the soil.

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 13 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Politeknik Negeri Cilacap
  • Bandung Institute of Technology
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Achmad MunirBandung Institute of Technology1
Chairunnisa ChairunnisaBandung Institute of Technology1
Artdhita Fajar PratiwiPoliteknik Negeri Cilacap1
Purwiyanto PurwiyantoPoliteknik Negeri Cilacap1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://jdmlm.ub.ac.id/index.php/jdmlm/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Leaching response of coastal sandy soils to subsurface hybrid ameliorant layering across homogeneous land units</dc:title>
	<dc:creator>Utami, Sari Widya</dc:creator>
	<dc:creator>Fadillah, Fadillah</dc:creator>
	<dc:creator>AJi, Galih Mustiko</dc:creator>
	<dc:subject xml:lang="en-US">hybrid ameliorant</dc:subject>
	<dc:subject xml:lang="en-US">leaching response</dc:subject>
	<dc:subject xml:lang="en-US">sandy soil</dc:subject>
	<dc:subject xml:lang="en-US">soil amendment</dc:subject>
	<dc:subject xml:lang="en-US">subsurface placement</dc:subject>
	<dc:description xml:lang="en-US">Sandy soil is characterized by a coarse texture, low organic content, low water-holding capacity, and rapid leaching. Soil amendments are usually applied to improve soil physicochemical characteristics, but their effects are only short-term. Subsurface hybrid ameliorant layering has been proposed as a means to reduce leaching in sandy soils. This study evaluated the leaching responses to subsurface hybrid ameliorant placement within the soil, using a soil column experiment with two factors: kinds of HLU (Homogeneous Land Unit) as the first factor, which consisted of eight HLUs, and ameliorant placement treatments as the second factor, which consisted of control treatment, conventional placement, and subsurface placement. The leaching response parameters were cumulative leachate volume and the differences in organic carbon, nitrogen, and phosphorus concentrations between the upper and bottom layers. The results showed that subsurface placement can reduce the cumulative leachate volume and increase N concentration in the upper layer after the incubation period, but did not significantly affect organic carbon or phosphorus availability in either layer. The application of this treatment resulted in different responses among HLUs, which were influenced by the natural physicochemical characteristics of the soil. </dc:description>
	<dc:publisher xml:lang="en-US">Brawijaya University</dc:publisher>
	<dc:date>2026-07-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jdmlm.ub.ac.id/index.php/jdmlm/article/view/17698</dc:identifier>
	<dc:identifier>10.15243/jdmlm.2026.133.10851</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Degraded and Mining Lands Management; Vol. 13 No. 3 (2026); 10851-10858</dc:source>
	<dc:source>2502-2458</dc:source>
	<dc:source>2339-076X</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jdmlm.ub.ac.id/index.php/jdmlm/article/view/17698/2116</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Journal of Degraded and Mining Lands Management</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-nc/4.0</dc:rights>
</oai_dc:dc>