Comparative Study on Solar Collector’s Configuration for an Ejector-Refrigeration Cycle

Journal of Engineering and Technological Sciences · Vol. 40 No. 1 (2013) · hlm. 61–77

DOI
10.5614/itbj.eng.sci.2008.40.1.4
ISSN
2338-5502, 2337-5779
Terbit
2013-09-13
Penerbit
Directorate for Research and Community Services, Institut Teknologi Bandung
Bahasa
eng

Abstrak

Solar collector’s configuration plays important role on solar-powered refrigeration systems to work as heat source for generator. Three types of solar collector consisting of flat plate, evacuated tube, and compound parabolic solar collectors are compared to investigate their performances. The performances consist of the behavior of heat which can be absorbed by the collectors, heat loss from the collectors and outlet temperature of working fluid at several slopes of the solar collectors. The new accurate analysis method of heat transfer is conducted to predict the performance of the solar collectors. The analysis is based on several assumptions, i.e. sky condition at Bandung is clear and not raining from 08.00 until 17.00 and thermal resistance at cover and absorber plate is negligible. The numerical calculation results confirm that performance of the evacuated tubes solar collector at the same operating conditions is higher than the others. For the case of an evacuated-tubes solar collector system with aperture area of 3.5 m2, the maximum heat which can be absorbed is 3992 W for the highest solar intensity of 970 W/m2 at 12.00 with horizontal position of the solar collector. At this condition, the highest outlet temperature of water is 347.15 K with mass flow rate 0.02 kg/s and inlet temperature 298 K.

Jaringan kolaborasi para penulis

8 penulis · 17 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Bandung Institute of Technology
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Prihadi Setyo DarmantoBandung Institute of Technology2
Izzan Hakim MuzakkiBandung Institute of Technology2
Firman Bagja JuangsaBandung Institute of Technology2
Alfi AmaliaAfiliasi tidak diketahui2
Arief SyahlanAfiliasi tidak diketahui2
Juristiawan FirmansyahBandung Institute of Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Comparative Study on Solar Collector’s Configuration for an Ejector-Refrigeration Cycle</dc:title>
	<dc:creator>Senjaya, Raffles</dc:creator>
	<dc:creator>Astina, I Made</dc:creator>
	<dc:description xml:lang="en-US">Solar collector’s configuration plays important role  on solar-powered refrigeration systems  to work as heat source for generator . Three types of solar collector consisting  of flat plate, evacuated tube, and compound parabolic solar collectors  are  compared  to  investigate  their  performances.  The  performances consist of the behavior of heat which can be absorbed by the collectors, heat loss from  the  collectors  and outlet temperature of working fluid at several slopes of the  solar  collectors.  The  new  accurate  analysis  method  of  heat  transfer  is conducted  to  predict  the  performance  of  the  solar  collectors.  The  analysis  is based  on  several  assumptions,  i.e.  sky  condition  at  Bandung  is  clear  and  not raining from 08.00 until 17.00 and thermal resistance at cover and absorber plate is  negligible. The numerical calculation results confirm that performance of  the evacuated  tubes  solar  collector  at  the  same  operating  conditions  is higher  than the  others.  For  the  case  of  an  evacuated-tubes  solar  collector  system  with aperture area of 3.5 m2, the maximum heat which can be absorbed is 3992  W for the highest solar intensity  of  970 W/m2 at 12.00  with  horizontal position of  the solar  collector.  At  this  condition,  the  highest  outlet  temperature  of  water  is 347.15 K with mass flow rate 0.02 kg/s and inlet temperature 298 K.</dc:description>
	<dc:publisher xml:lang="en-US">Directorate for Research and Community Services, Institut Teknologi Bandung</dc:publisher>
	<dc:date>2013-09-13</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jets/article/view/60</dc:identifier>
	<dc:identifier>10.5614/itbj.eng.sci.2008.40.1.4</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Engineering and Technological Sciences; Vol. 40 No. 1 (2008); 61-77</dc:source>
	<dc:source>2338-5502</dc:source>
	<dc:source>2337-5779</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jets/article/view/60/56</dc:relation>
</oai_dc:dc>