Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Confinement of Reinforced-Concrete Columns with NonCode Compliant Confining Reinforcement plus Supplemental Pen-Binder

Journal of Engineering and Technological Sciences · Vol. 44 No. 3 (2013) · hlm. 220–237

DOI
10.5614/itbj.eng.sci.2012.44.3.2
ISSN
2338-5502, 2337-5779
Terbit
2013-09-13
Penerbit
Directorate for Research and Community Services, Institut Teknologi Bandung
Bahasa
eng

Abstrak

Abstract. One of the important requirements for earthquake resistant building related to confinement is the use of seismic hooks in the hoop or confining reinforcement of reinforced-concrete column elements. However, installation of a confining reinforcement with a 135-degree hook is not easy. Therefore, in practice, many construction workers apply a confining reinforcement with a 90-degree hook (non-code compliant). Based on research and records of recent earthquakes in Indonesia, the use of a non-code compliant confining reinforcement for concrete columns produces structures with poor seismic performance. This paper presents a study that introduces an additional element that is expected to improve the effectiveness of concrete columns confined with a non-code compliant confining reinforcement. The additional element, named a pen-binder, is used to keep the non-code compliant confining reinforcement in place. The effectiveness of this element under pure axial concentric loading was investigatedcomprehensively.The specimens tested in this study were 18 concrete columns,with a cross-section of 170 mm x 170 mm and a height of 480 mm. The main test variables were the material type of the pen-binder, the angle of the hook, and the confining reinforcement configuration.The test results indicate that adding pen -binders can effectively improve the strength and ductility of the column specimens confined with a non-code compliant confining reinforcement.

Jaringan kolaborasi para penulis

33 penulis · 79 tautan kepenulisan bersama · 29 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Bandung Institute of Technology
  • The University of Melbourne
  • Andalas University
  • Maranatha Christian University
  • Sultan Agung Islamic University
  • University of Nusa Cendana
  • Politeknik Negeri Bandung
  • Organisasi lain
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Bambang BudionoBandung Institute of Technology6
Siti Aisyah NurjannahBandung Institute of Technology2
Muslinang MoestopoBandung Institute of Technology2
Bambang SunendarBandung Institute of Technology2
Partogi Hasudungan SimatupangUniversity of Nusa Cendana2
Ediansjah ZulkifliBandung Institute of Technology2
Yurisman YurismanBandung Institute of Technology1
Antonius AntoniusSultan Agung Islamic University1
Riawan GunadiPoliteknik Negeri Bandung1
Ananta SofwanBandung Institute of Technology1
Awal SuronoBandung Institute of Technology1
Ruddy KurniawanAndalas University1
Saptahari SugiriBandung Institute of Technology1
Tito AdibaskoroBandung Institute of Technology1
Masyhur IrsyamBandung Institute of Technology1
Muhammad AsrurifakBandung Institute of Technology1
Delfebriyadi DelfebriyadiAndalas University1
Bigman Marihat HutapeaBandung Institute of Technology1
Daniel Dixon OctoraDirektorat Jenderal Bina Marga1
Muhammad RiyansyahBandung Institute of Technology1
Herwani HerwaniBandung Institute of Technology1
Herlien Dwiarti SetioBandung Institute of Technology1
Veby Citra SimanjuntakMinistry of Public Works, Republic of Indonesia1
Indra Djati SidiBandung Institute of Technology1
Widi NugrahaMinisterio de Transportes, Movilidad y Agenda Urbana1
Anita AmirsardariThe University of Melbourne1
Massoud SofiThe University of Melbourne1
Elisa LumantarnaThe University of Melbourne1
Colin Fraser DuffieldThe University of Melbourne1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Confinement of Reinforced-Concrete Columns with NonCode Compliant Confining Reinforcement plus Supplemental Pen-Binder</dc:title>
	<dc:creator>Kristianto, Anang</dc:creator>
	<dc:creator>Imran, Iswandi</dc:creator>
	<dc:creator>Suarjana, Made</dc:creator>
	<dc:creator>Pane, Ivindra</dc:creator>
	<dc:description xml:lang="en-US">Abstract.  One  of  the  important  requirements  for  earthquake  resistant  building related  to  confinement  is  the  use  of  seismic  hooks  in  the  hoop  or  confining reinforcement  of  reinforced-concrete  column  elements. However, installation of a  confining  reinforcement  with  a  135-degree  hook  is  not  easy.  Therefore,  in practice, many construction workers apply a confining reinforcement with a  90-degree  hook  (non-code  compliant).  Based  on  research  and  records  of  recent earthquakes  in  Indonesia,  the  use  of  a  non-code  compliant  confining reinforcement  for  concrete  columns  produces  structures  with  poor  seismic performance.  This paper  presents a study  that  introduces  an additional element that is expected to improve the effectiveness of concrete columns confined with a non-code compliant  confining reinforcement. The additional element, named a pen-binder,  is   used to keep the  non-code compliant  confining reinforcement in place. The effectiveness of this element  under pure axial concentric loading  was investigatedcomprehensively.The  specimens  tested  in  this  study  were  18 concrete columns,with a cross-section of 170 mm x 170 mm and a height of 480 mm. The main test variables were the material type of the  pen-binder, the angle of  the  hook,  and  the  confining  reinforcement  configuration.The  test  results indicate  that  adding  pen -binders  can  effectively  improve  the  strength  and ductility of the column specimens confined with a non-code compliant  confining reinforcement. </dc:description>
	<dc:publisher xml:lang="en-US">Directorate for Research and Community Services, Institut Teknologi Bandung</dc:publisher>
	<dc:date>2013-09-13</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jets/article/view/195</dc:identifier>
	<dc:identifier>10.5614/itbj.eng.sci.2012.44.3.2</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Engineering and Technological Sciences; Vol. 44 No. 3 (2012); 220-237</dc:source>
	<dc:source>2338-5502</dc:source>
	<dc:source>2337-5779</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jets/article/view/195/189</dc:relation>
</oai_dc:dc>